DOWNLOAD Sharp XV-Z100 (serv.man2) Service Manual ↓ Size: 20.24 MB | Pages: 127 in PDF or view online for FREE

Model
XV-Z100 (serv.man2)
Pages
127
Size
20.24 MB
Type
PDF
Document
Service Manual
Brand
Device
Projector / Complete Service Manual
File
xv-z100-sm2.pdf
Date

Sharp XV-Z100 (serv.man2) Service Manual ▷ View online

XV-Z100
In the interests of user-safety (Required by safety regulations in some countries) the set should be re-
stored to its original condition and only parts identical to those specified should be used.
MODEL
MODELL
XV-Z100
MULTIMEDIA PROJECTOR
MULTIMEDIA-PROJEKTOR
Im lnteresse der Benutzersicherheit (erforderliche Sicherheitsregeln in einigen Ländern) muß das Gerät in seinen
Originalzustand  gebracht werden.  Außerdem dürfen für die spezifizierten Bauteile nur identische Teile verwendet
werden.
SERVICE MANUAL
SERVICE-ANLEITUNG
SHARP CORPORATION
S65K9XR-10X/S
1st Edition
2
XV-Z100
CONTENTS
Page
Page
INHALT
Seite
Seite
• SPECIFICATIONS ............................................ 3
• IMPORTANT SERVICE SAFETY
NOTES (for USA) .............................................. 4
• NOTE TO SERVICE PERSONNEL .................. 6
• OPERATION MANUAL ................................... 10
• DIMENSIONS ................................................. 16
• RESETTING THE TOTAL LAMP TIMER ......... 17
• REMOVING OF MAJOR PARTS ..................... 19
• THE OPTICAL UNIT OUTLINE ...................... 22
• ELECTRICAL ADJUSTMENT ......................... 24
• TROUBLE SHOOTING TABLE ....................... 30
• BLOCK DIAGRAM .......................................... 72
• OVERALL WIRING DIAGRAM ........................ 74
• DESCRIPTION OF SCHEMATIC DIAGRAM .. 76
• WAVEFORMS ................................................. 77
• SCHEMATIC DIAGRAM ................................. 78
• PRINTED WIRING BOARD ASSEMBLIES ... 106
• PARTS LIST
Ë 
ELECTRICAL PARTS ............................... 126
Ë 
CABINET AND MECHANICAL PARTS .... 137
Ë
  ACCESSORIES PARTS ........................... 141
Ë
  PACKING PARTS ..................................... 141
• PACKING OF THE SET ................................ 142
• SPEZIFIKATIONEN ........................................ 39
• HINWEISE FÜR DAS
WARTUNGSPERSONAL ................................ 40
• BEDIENUNGSANLEITUNG ............................ 42
• ABMESSUNGEN ............................................ 48
• RÜCKSTELLEN DES
LAMPENBETRIEBSZEIT-TIMERS ................. 49
• ENTFERNEN DER HAUPTTEILE .................. 51
• BESCHREIBUNG DER OPTIK-EINHEIT ........ 54
• ELEKTRISCHE EINSTELLUNG ..................... 56
• FEHLERSUCHTABELLE ................................ 63
• BLOCKSCHALTBILD ...................................... 72
• GESAMTSCHALTPLAN .................................. 74
• BESCHREIBUNG DES SCHEMATISCHEN
SCHALTPLANS .............................................. 76
• WELLENFORMEN .......................................... 77
• SCHEMATISCHER SCHALTPLAN ................. 78
• LEITERPLATTENEINHEITEN ....................... 106
• ERSATZTEILLISTE
Ë
 ELEKTRISCHE BAUTEILE ....................... 126
Ë
 GEHÄUSE UND MECHANISCHE
    BAUTEILE ................................................. 137
Ë
 ZUBEHÖRTEILE ....................................... 141
Ë
 VERPACKUNGSTEILE ............................. 141
• VERPACKEN DES GERÄTS ........................ 142
3
XV-Z100
SPECIFICATIONS
Projector
XV-Z100
NTSC3.58/NTSC4.43/PAL/PAL-M/PAL-N/PAL-60/SECAM/DTV480
I
/DTV480P/
DTV540P/DTV576
I
/DTV576P/DTV720P/DTV1035
I
/DTV1080
I
/DTV1080
I
-50
Single Chip Digital Micromirror Device
TM
 (DMD
TM
) by Texas Instruments
Panel size:  0.55" (14 mm), 1chip WVGA DMD
No. of dots: 480,000 dots (800 [H]  600 [V])
1–1.15  
zoom 
lens, 
F2.4–2.6, f = 19.0–21.9 mm
275 W DC lamp
15-pin mini D-sub connector
Y: 1.0 Vp-p, sync negative, 75
 terminated
P
B
: 0.7 Vp-p, 75
 terminated
P
R
: 0.7 Vp-p, 75
 terminated
520 TV lines (DTV720P) 
15-pin mini D-sub connector
RGB separate/sync on green type analog input: 0–0.7 Vp-p, positive, 75
 terminated
HORIZONTAL SYNC. SIGNAL: TTL level (positive/negative)
VERTICAL SYNC. SIGNAL: Same as above
4-pin mini DIN connector
Y (luminance signal): 1.0 Vp-p, sync negative, 75
 terminated
C (chrominance signal): Burst 0.286 Vp-p, 75
 terminated
RCA connector: VIDEO, composite video, 1.0 Vp-p, sync negative, 75
terminated
45–85 Hz
15–70 kHz
12–108 MHz
9-pin mini DIN connector
ø3.5 mm minijack or RCA terminal: 0.5 Vrms, more than 22 k  (stereo)
ø3.5 mm minijack: 0.5 Vrms, less than 2.2 k
4 cm  2.85 cm oval   1
AC 100–240 V
3.6 A
50/60 Hz
350 W (Lamp Setting  “Bright”)/
305 W (Lamp Setting  “Eco + Quiet”) with AC 100 V
330 W (Lamp Setting  “Bright”)/
285 W (Lamp Setting  “Eco + Quiet”) with AC 240 V
4 W (AC 100 V) – 5 W (AC 240 V)
1,315 BTU/hour (Lamp Setting  “Bright”)/
1,145 BTU/hour (Lamp Setting  “Eco + Quiet”) with AC 100 V
1,240 BTU/hour (Lamp Setting  “Bright”)/
1,070 BTU/hour (Lamp Setting  “Eco + Quiet”) with AC 240 V
41°F to 95°F (+5°C to +35°C)
–4°F to 140°F (–20°C to +60°C)
Plastic
38 kHz
12 
13
/
32
"   4 
19
/
64
"   11 
1
/
32
" (315 (W)  109 (H)  280 (D) mm) (main body only)
12 
13
/
32
"   4 
47
/
64
"   11 
37
/
64
" (315 (W)  120 (H)  294 (D) mm) (including adjust-
ment foot and projecting parts)
8.6 lbs. (3.9 kg)
Remote control, Power cord for Europe, except U.K., Power cord for U.K.
 and Singapore, Power cord for Australia, New Zealand and Oceania, 
10M Video cable, RGB-RCA cable, Operation manual.
Product type
Model
Video system
Display method
DMD panel
Lens
Projection lamp
Component input signal
(INPUT1/2)
Horizontal resolution
Computer RGB input
(INPUT 1/2)/output
(OUTPUT) signal
S-video input signal
(INPUT 3)
Video input signal
(INPUT 4)
Vertical frequency
Horizontal frequency
Pixel clock
RS-232C terminal
Audio input signal
Audio output signal
(AUDIO OUTPUT 1-4)
Speaker system
Rated voltage
Input current
Rated frequency
Power consumption
Power consumption (standby)
Heat dissipation
Operating temperature
Storage temperature
Cabinet
I/R carrier frequency
Dimensions (approx.)
Weight (approx.)
Replacement parts
As a part of policy of continuous improvement, SHARP reserves the right to make design and
specification changes for product improvement without prior notice. The performance specifica-
tion figures indicated are nominal values of production units. There may be some deviations from
these values in individual units.
×
×
×
×
×
×
×
×
×
×
×
×
4
XV-Z100
IMPORTANT SERVICE SAFETY NOTES (for USA)
Ë
Service work should be performed only by qualified service technicians who are
thoroughly familiar with all safety checks and servicing guidelines as follows:
WARNING
1. For continued safety,  no modification of any circuit
should be attempted.
2. Disconnect AC power before servicing.
BEFORE RETURNING THE PROJECTOR:
(Fire & Shock Hazard)
Before returning the projector to the user,  perform
the following safety checks:
1. Inspect lead wires are not pinched between the chassis
and other metal parts of the projector.
2. Inspect all protective devices such as non-metallic
control knobs, insulating materials, cabinet backs,
adjustment and compartment covers or shields,
isolation resistor-capacity networks, mechanical
insulators, etc.
3. To be sure that no shock hazard exists, check for
current leakage in the following manner:
»
Plug the AC cord directly into a 120-volt AC outlet,  (Do
not use an isolation transformer for this test).
»
Using two clip leads, connect a 1.5k ohm, 10 watt
resistor paralleled by a 0.15µF capacitor in parallel
between all exposed metal cabinet parts and earth
ground.
»
Use an AC voltmeter with sensitivity of 5000 ohm per
volt.,  or higher,  sensitivity to measure the AC voltage
drop across the resistor (See Diagram).
»
All checks must be repeated with the AC plug
connection reversed.  (If necessary,  a non-polarized
adapter plug must be used only for the purpose of
completing these checks.)
Any reading of 0.3 volts RMS (this corresponds to 0.2
milliamp. AC.) or more is excessive and indicates a
potential shock hazard which must be corrected before
returning the unit to the owner.
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
12345678901234567890123456789012123456789012345678901234567890121234567890123456789012345678901212
SAFETY NOTICE
Many electrical  and  mechanical parts in DMD™
Projector have special safety-related characteristics.
These characteristics are often not evident from visual
inspection, nor can protection afforded by them be
necessarily increased by using replacement components
rated for higher voltage, wattage, etc.
Replacement parts which have these special safety
characteristics are identified in this manual; electrical
components having such features are identified  by “
å
and  shaded  areas in the Replacement Parts Lists and
Schematic Diagrams.  For continued protection,
replacement parts must be identical to those used in
the original circuit.  The use of a substitute replacement
parts which do not have the same safety characteristics
as the factory recommended replacement parts shown
in this service manual, may create shock,  fire or other
hazards.
AVIS POUR LA SECURITE
De nombreuses pièces, électriques et mécaniques, dans
les projecteur à DMD™ présentent des caractéristiques
spéciales relatives à la sécurité,  qui ne sont souvent pas
évidentes à vue.
Le degré de protection ne peut pas être nécessairement
augmentée en utilisant des pièces de remplacement
étalonnées pour haute tension, puissance,  etc.
Les pièces de remplacement qui présentent ces
caractéristiques sont identifiées dans ce manuel;
les pièces électriques qui présentent ces particularités
sont identifiées par la marque “
å
” et hachurées dans la
liste des pièces de remplacement et les diagrammes
schématiques.  Pour assurer la protection, ces pièces
doivent être identiques à  celles  utilisées dans le circuit
d’origine.  L’utilisation de pièces qui n’ont pas les mêmes
caractéristiques que les pièces recommandées par l’usine,
indiquées dans ce manuel, peut provoquer des
électrocutions, incendies ou autres accidents.
WARNING: The bimetallic component has the primary
conductive side exposed. Be very careful in
handling this component when the power is on.
AVERTISSEMENT: La composante bimétallique dispose du
conducteur primaire dénudé. Faire attention
lors de la manipulation de cette
composante sous tension.
DVM
AC SCALE
1.5k ohm
10W
TO EXPOSED
METAL PARTS
CONNECT TO
KNOWN EARTH
GROUND
0.15 µF
TEST PROBE
Page of 127
Display

Sharp XV-Z100 (serv.man2) Service Manual ▷ Download

  • DOWNLOAD Sharp XV-Z100 (serv.man2) Service Manual ↓ Size: 20.24 MB | Pages: 127 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the Sharp XV-Z100 (serv.man2) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp XV-Z100 (serv.man2) Projector. Information contained in Sharp XV-Z100 (serv.man2) Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.