DOWNLOAD Sharp MX-M850 (serv.man37) Service Manual ↓ Size: 1.17 MB | Pages: 103 in PDF or view online for FREE

Model
MX-M850 (serv.man37)
Pages
103
Size
1.17 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Section 7 Simulation
File
mx-m850-sm37.pdf
Date

Sharp MX-M850 (serv.man37) Service Manual ▷ View online

MX-M1100  SIMULATION  7 – 97
116
1, 2
[Line 2] Send/receive 
coding capacity 
(Communication other than 
V.34)
(Reflected on DIS/DCS/
DTC)
JBIG/MMR/MR/MH
0 0
0
JBIG/MMR/MR/
MH
MMR/MR/MH
0 1
0
MR/MH
1 0
MH
1 1
3 - 6
[Line 2] MODEM send 
speed (Other than V.34) 
(DCS)
V.27ter  2400bps
0 0 0 0
1
V.17 14400bps
* For mark bit, set to 
V.17 14400 bps.
Setting for 
communication 
other than V.34
V.29  9600bps
0 0 0 1
0
V.27ter 4800bps
0 0 1 0
0
V.29  7200bps
0 0 1 1
0
V.33  14400bps
0 1 0 0
*
0  1  0  1
V.33  12000bps
0 1 1 0
*
0  1  1  1
V.17  14400bps
1 0 0 0
V.17   9600bps
1 0 0 1
V.17  12000bps
1 0 1 0
V.17   7200bps
1 0 1 1
*
1  1  0  0
*
1  1  0  1
*
1  1  1  0
*
1  1  1  1
7, 8
[Line 2] MODEM speed 
fixed when receiving (Other 
than V.34)
(DIS)
Fixed to NO
0 0
0
Fixed to NO
Setting for 
communication 
other than Super 
G3
Max. speed when 
receive
V.29-9600bps
0 1
0
V.27ter-4800bps
1 0
V.17-14400bps
1 1
117
1
Adjustment 
value
[Line 2] Signal send level
For setting over the max. 
send level, set to the max. 
value of the destination. 
Binary input
When set to 22 - 225, 
the operation is 
executed as setting of 
21.
The send level to the line 
is virtually same as the 
set value. 
Set value is 0 - 21
0
-10dBm
-8dBm
2
0
3
0
4
0
5
1
6
0
7
1
8
0
118
1 - 4 
Not  used
1
0
0
0
5 - 8
FAX initial 
setting
[Line 2] Auto receive call 
number setting
Binary input
0
2 times
No ring for 0 time 
setting
Receive (However, 
except for nighttime 
FAX mode)
Setting range:
Japan / North America / 
Taiwan / India
0 - 15 times
0
Europe / Indonesia / 
Thailand
0 - 9 times
1
Australia / NZL
2 - 4 times
0
119
1, 2
Not used
0
0
3
[Line 2] DPMUTE control
1:  ON
0: OFF
0
OFF
4
[Line 2] DTMF signal send 
time
Setting range
Binary input
710 - 310ms
10ms unit
0
110ms
When set to "69ms 
or less," the default 
value of "110ms" is 
used. 
5
1
6
0
7
1
8
1
120
1
Adjustment 
value
[Line 2] DTMF minimum 
pause time setting
Setting range
Binary input
50 -255ms
1ms interval
0
120ms
When set to "49ms 
or less," the default 
value of "120ms" is 
used. 
2
1
3
1
4
1
5
1
6
0
7
0
8
0
SW 
No.
Bit 
No.
System 
settings
Item
SW selection and function
Initial value
Remarks
MX-M1100  SIMULATION  7 – 98
121
1 - 4
Adjustment 
value
[Line 2] DTMF send level 
(high group) setting
Setting range
Binary input
0 -15
1db interval
1
0
0
0
5 - 8
Adjustment 
value
[Line 2]  DTMF send level 
(low group) setting
High group - Low group: 
Level difference
-2.0dB
0 0 0 0
1
High group - Low 
group
-1.5dB
0 0 0 1
0
-1.0dB
0 0 1 0
0
-0.5dB
0 0 1 1
0
0.0dB
0 1 0 0
0.5dB
0 1 0 1
1.0dB
0 1 1 0
1.5dB
0 1 1 1
2.0dB
1 0 0 0
2.5dB
1 0 0 1
3.0dB
1 0 1 0
3.5dB
1 0 1 1
4.0dB
1 1 0 0
4.5dB
1 1 0 1
5.0dB
1 1 1 0
5.5dB
1 1 1 1
122
1 - 4
Adjustment 
value
[Line 2] Make time (10PPS) 
setting
Setting range
Binary input
29 - 44ms
1ms interval
0
33ms
1
0
0
5 - 8
Adjustment 
value
[Line 2] Break time (10PPS) 
setting
Setting range
Binary input
56 - 71ms
1ms interval
1
67ms
0
1
1
123
1 - 4
Adjustment 
value
[Line 2] Minimum pause 
time (10PPS) setting
Setting range
Binary input
800ms - 950ms
10ms interval
0
800ms
0
0
0
5 - 8
Adjustment 
value
[Line 2] Minimum pause 
time (20PPS) setting
Setting range
Binary input
450ms - 600ms
10ms interval
0
460ms
0
0
1
124
1 - 4
Adjustment 
value
[Line 2] Make time (20PPS) 
setting
Setting range
Binary input
9 - 24ms
1ms interval
1
17ms
0
0
1
5 - 8
Adjustment 
value
[Line 2] Break time (20PPS) 
setting
Setting range
Binary input
26 - 41ms
1ms interval
1
33ms
0
0
0
125
1
[Line 2] No. 2 dial tone 
detection 
1:  YES
0: NO
0
NO
Support from BOX 
Ver01.03
2 - 8
Not used
0
126
1 - 3
Not used
0
4
[Line 2] Busy tone ON  non-
detection time 
1:  300ms
0: 100ms
0
100ms
Must be shorter 
than the busy tone 
OFF detection time.
5, 6
[Line 2] Busy tone OFF 
detection time lower limit
250ms
0 0
0
250ms
140ms
0 1
0
450ms
1 0
350ms
1 1
7,  8
[Line 2] Busy tone ON 
detection time upper limit
750ms
0 0
0
750ms
650ms
0 1
0
1000ms
1 0
2850ms
1 1
SW 
No.
Bit 
No.
System 
settings
Item
SW selection and function
Initial value
Remarks
MX-M1100  SIMULATION  7 – 99
127
1, 2
[Line 2] Busy tone OFF 
detection time lower limit
250ms
0 0
0
250ms
140ms
0 1
0
450ms
1 0
350ms
1 1
3,  4
[Line 2] Busy tone OFF 
detection time upper limit 
750ms
0 0
0
750ms
650ms
0 1
0
1000ms
1 0
2850ms
1 1
5 - 8
[Line 2] Call signal OFF 
non-detection time
Setting range
Binary input
0 - 1500ms
100ms unit
0
400ms
1
0
0
128
1 - 4
[Line 2] Call signal ON time 
lower limit
Setting range
Binary input
150 - 300ms
10ms interval
0
150ms
The sine wave of CI 
detection is 
substituted by this 
switch.
0
0
0
5 - 8
[Line 2] Call signal ON time 
upper limit
Setting range
Binary input
3000ms - 4500ms
100ms interval
0
3000ms
0
0
0
129
1 - 4
[Line 2] Call signal OFF 
time lower limit
Setting range
Binary input
0 - 1500ms
100ms unit
0
700ms
1
1
1
5, 6
[Line 2] Call signal OFF 
time upper limit
6.5 sec
0 0
0
6.5 sec
10 sec
0 1
0
15 sec
1 0
20 sec
1 1
7
[Line 2]  V.34 mode function 
(including polling when 
calling)
1:  Off
0: On
0
ON
8
[Line 2] V.34 mode function 
(when call-in)
1:  Off
0: On
0
ON
130
1
[Line 2] Dial tone ON 
detection time 
(when continuous 
detection)
1:  1 sec
0: 1.5 sec
0
1.5 sec
2, 3
[Line 2] DP dial pulse 
number process
NORMAL
(Pulse = DIAL, 10=0)
0 0
0
NORMAL
EXTEND
(Pulse = DIAL + 1)
0 1
0
REVERSE
(Pulse = 10-DIAL)
1 0
Same as 00
1 1
4
[Line 2] Dial tone detection
1:  YES
0: NO
1
YES
5
[Line 2] Busy tone detection 
1:  NO
0: YES
0
YES
6, 7
[Line 2] Busy tone detection 
cycle
2 pulse
0 0
0
3 pulse
0 1
0
4 pulse
1 0
6 pulse
1 1
8
Not Used
0
131
1 - 4
[Line 2] dial tone ON/OFF 
detection time lower limit 
(When continuous 
detection)
Default
0 : 40
40 + N * 30
Min.: 40, Max.: 490
0
100ms
Enable only when 
DT detection 
continue
0
1
0
5 - 8
[Line 2] Dial tone ON/OFF 
detection time upper limit 
(When continuous 
detection)
Default
0 : 400
400 + N * 100
Min.: 400, Max.: 1900
0
Enable only when 
DT detection 
continue
0
1
1
132
1 - 8
Not used
0
0
0
1
0
0
1
1
SW 
No.
Bit 
No.
System 
settings
Item
SW selection and function
Initial value
Remarks
MX-M1100  SIMULATION  7 – 100
133
1 - 8
Not used
"00000100": North America/China/Thailand/
Malaysia/Philippine/Taiwan/Rusia
"00001000": Singapore/Indonesia/India/
Hong Kong/Middle East
"00100100": Other3
"00101000": New Zealand/South Africa
"01100100": Australia
"00101100": Other country
134
1 - 8
Not used
"00000000": North America/Australia/
New Zealand/China/Singapore/Indonesia/
Thailand/Malaysia/India/Philippine/Hong 
Kong/Taiwan/Middle East/Rusia/South Africa
"00010000": Other country
135
1 - 8
Not used
0
0
0
0
0
0
1
0
136
1 - 5
[Line 2] Receive gain 
correction 
Setting range
Binary input
0 (+6.0dBm)
 - 24 (-6.0dBm)
-0.5dBm interval
0
0.0dBm
1
1
0
0
6 - 8
Not used
1
1
1
137
1 - 4
Not used
0
0
0
0
5 - 8
[Line 2] Flag detection byte 
number
Setting range
Binary input
0 - 15
1byte interval
0
4
When set to 0, the 
default value is 
used. 
1
0
0
138
1, 2
[Line 2] Min. number of 
flags between frames
0: 2-flag
0 0
0
2-flag
1: 3-flag
0 1
0
2: 4-flag
1 0
3: 5-flag
1 1
3
Not used
0
4
[Line 2] Rind detection 
signal selection
1: Silicon DAA-RGDT 
signal
0: Ring detection circuit
0
Ring detection 
circuit
Support from BOX 
Ver 01b02
1: Ring detection circuit
0: Silicon DAA-RGDT 
signal
Silicon DAA-
RGDT signal
5
[Line 2] V.17 carrier 
frequency
0: 1800Hz
1: 1700Hz
0
1800Hz
6
[Line 2] V.33 carrier 
frequency
0: 1800Hz
0: 1700Hz
0
1800Hz
7, 8
[Line 2] V17/V33/V29/V27 
ter TCF receive judgment 
EQM threshold value
0x20
0 0
1
0x58
0x40
0 1
0
0x58
1 0
0x7f
1 1
139
1, 2
[Line 2] Primary channel fall 
back EQM threshold value 
when V.34 receive 
0x20
0 0
1
0x58
0x40
0 1
0
0x58
1 0
0x7f
1 1
3 - 6
Not used
1
1
0
1
7
[Line 2] Manual calibration 
setting when sending
1: Not Execute
0: Execute
0
Execute
8
[Line 2] Manual calibration 
setting when receiving
1: Not Execute
0: Execute
0
Execute
SW 
No.
Bit 
No.
System 
settings
Item
SW selection and function
Initial value
Remarks
Page of 103