DOWNLOAD Sharp MX-M850 (serv.man37) Service Manual ↓ Size: 1.17 MB | Pages: 103 in PDF or view online for FREE

Model
MX-M850 (serv.man37)
Pages
103
Size
1.17 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Section 7 Simulation
File
mx-m850-sm37.pdf
Date

Sharp MX-M850 (serv.man37) Service Manual ▷ View online

MX-M1100  SIMULATION  7 – 81
23
1
FAX 
reception 
setting
Setting for changing over to 
automatic reception during 
manual reception
1: Permitted 
(changeover)
0: Prohibited (do not 
changeover)
0
Prohibited
The number of calls 
is set in "Setting of 
the number of calls 
for changing over 
from manual to 
automatic 
reception."
2 - 6
FAX 
reception 
setting
Setting of the number of 
calls for changing over from 
manual to automatic 
reception (Selection setting 
from manual reception to 
automatic reception)
Binary input
1 to 9 times
Setting range
1 time intervals
The number of calls for changing
Set value + 1
0
9 times
Function setting for 
"Setting for 
changing over to 
automatic reception 
during manual 
reception"
For outside the set 
range, the default 
value is used.
Functions only in 
France.
1
0
0
0
7
Polling 
protection 
setting
Polling protection
1: Do not protect
0: Protect
0
Protect
8
Switch to sorting in order of 
numbers on the address list
1: Registered number 
order
0: Search number order
0
Search number 
order
24
1
Receiver off-hook (External 
telephone)
1: Warns off-hook state 
of the external 
telephone.
0: Does not warn off-
hook state of the 
external telephone.
"0": Does not warn off-
hook state of the 
external telephone. 
(North America/
Australia/New 
Zealand/China/
Singapore/Indonesia/
Thailand/Malaysia/
India/Philippine/Hong 
Kong/Taiwan/Middle 
East/Other3)
"1": Warns off-hook 
state of the external 
telephone. 
(Other country)
Limited by the TEL/
LIU PWB.
2 - 5
Not used
1
0
0
0
6
Scope of line sound monitor
1: All
0: Until NSF signal send/
receive
0
Until NSF signal 
send/receive
7, 8
Volume setting of call sound 
(large)
Volume level 9
0 0
1
Volume level 13
Related to BZ
Calling sound/ 
Communication end 
sound (Normal, 
Error)
Volume level 11
0 1
0
Volume level 13
1 0
Volume level 15
1 1
25
1, 2
Volume setting of call sound 
(medium)
Volume level 3
0 0
0
Volume level 5
Related to BZ
Calling sound/ 
Communication end 
sound (Normal, 
Error)
Volume level 5
0 1
1
Volume level 7
1 0
Volume level 9
1 1
3, 4
Volume setting of call sound 
(small)
Volume level 0 
(no sound)
0 0
1
Volume level 2
Related to BZ
Calling sound/ 
Communication end 
sound (Normal, 
Error)
Volume level 1
0 1
0
Volume level 2
1 0
Volume level 3
1 1
5, 6
Volume setting of line 
monitor sound (large)
Volume level 9
0 0
1
Volume level 15
Line Monitor sound
When on-hook
Receiver off-hook 
warning sound
Volume level 11
0 1
1
Volume level 13
1 0
Volume level 15
1 1
7, 8
Volume setting of line 
monitor sound (medium)
Volume level 5
0 0
1
Line Monitor sound
When on-hook
Receiver off-hook 
warning sound
Volume level 7
0 1
1
Volume level 9
1 0
Volume level11
1 1
SW 
No.
Bit 
No.
System 
settings
Item
SW selection and function
Initial value
Remarks
MX-M1100  SIMULATION  7 – 82
26
1, 2
Volume setting of line 
monitor sound (small)
Volume level 1
0 0
1
Line Monitor sound
When on-hook
Receiver off-hook 
warning sound
Volume level 3
0 1
0
Volume level 5
1 0
Volume level 7
1 1
3
Not used
0
4
Remote changeover 
permitted
1: Changeover enable 
for call-out/call-in
0: Changeover enable 
only for call-in
0
Only for call-in
North America: This 
SW is ignored and 
changeover is 
enabled for call-out/
call-in.
5 - 7
Setting of call time (T0 timer 
setting) in automatic 
transmission
Setting range <Binary input>
(Rusia) 30 seconds to 35 seconds: 
5 seconds intervals
(China) 30 seconds to 45 seconds
(Other country) 30 seconds to 60 seconds: 
15 seconds intervals
"001": 35 seconds 
(Rusia)
"001": 45 seconds 
(Other country)
For outside the set 
range, the default 
value is used.
8
External telephone setting 
when no sound is set
1: No sound priority
0: Priority on external 
telephone send
0
Priority on 
external telephone 
send
27
1 - 8
External telephone off-hook 
detection time
Setting range
Binary input
0ms to 2550ms
10ms intervals
0
300ms
0
0
1
1
1
1
0
28
1 - 8
Not used
0
29
1 - 8
Not used
0
1
0
1
1
0
1
0
30
1 - 8
Not used
0
0
0
0
0
0
1
0
31
1 - 4
Not used
"1100": France/Germany
"0000": Other country
5
Document content print 
when sending (PC-Fax 
(Internet Fax) report table)
1: Print
0: Not print
0
Not print
6 - 8
Not used
1
0
1
32
1 - 4
T1 timer setting
Setting range
Binary input
30 to 105 seconds
5 seconds intervals
0
40 seconds
0
1
0
5 - 8
Not used
0
0
0
0
SW 
No.
Bit 
No.
System 
settings
Item
SW selection and function
Initial value
Remarks
MX-M1100  SIMULATION  7 – 83
33
1, 2
T4 timer setting 
Timer during automatic 
operation
3 seconds
0 0
0
3 seconds
+1.5 seconds at 
times of manual 
operation
4 seconds
0 1
0
5 seconds
1 0
6 seconds
1 1
3
Not used
0
4
Selection of date and 
transmission source print 
language <Format>
1: North American 
format
0: Follows the date 
format setting.
0
Follows the date 
format setting.
5
EOL detection timer
1: 25 seconds
0: 13 seconds
0
13 seconds
6 - 8
Not used
"010": North America
"011": Taiwan
"100": Thailand/Rusia/South Africa
"001": Other country
34
1, 2
Not used
0
0
3 - 6
Modem transmission speed 
(Other than V.34) (DCS)
V.27ter
2400bps
0 0 0 0
1
V.17 14400bps
Setting in 
communication 
other than V.34
V.29
9600bps
0 0 0 1
0
V.27ter
4800bps
0 0 1 0
0
V.29
7200bps
0 0 1 1
0
V.33
14400bps
0 1 0 0
V.17
14400bps
0 1 0 1
V.33
12000bps
0 1 1 0
V.17
14400bps
0 1 1 1
V.17
14400bps
1 0 0 0
V.17
9600bps
1 0 0 1
V.17
12000bps
1 0 1 0
V.17
7200bps
1 0 1 1
V.17
14400bps
1 1 0 0
V.17
14400bps
1 1 0 1
V.17
14400bps
1 1 1 0
V.17
14400bps
1 1 1 1
7, 8
Fixing of modem speed 
during reception (Other than 
V.34) (DIS)
Not fixed
0 0
0
Not fixed
Setting in 
communication 
other than V.34
Max .speed in 
reception
V.29-9600bps
0 1
0
V.27ter-4800bps
1 0
V.17-14400bps
1 1
35
1, 2
Coding capacity during 
transmission and reception 
(V.34 communication) 
(reflected in DIS/DCS/DTC)
JBIG/MMR/MR/MH
0 0
0
JBIG/MMR/MR/
MH
MMR/MR/MH
0 1
0
MR/MH
1 0
MH
1 1
3, 4
Coding capacity during 
transmission and reception 
(other than V.34 
communication) (reflected 
in DIS/DCS/DTC)
JBIG/MMR/MR/MH
0 0
0
JBIG/MMR/MR/
MH
MMR/MR/MH
0 1
0
MR/MH
1 0
MH
1 1
5, 6
Not used
1
1
7, 8
Image capacity when 
polling (Reflected in DTC)
Very fine
0 0
0
Very fine
Fine
0 1
0
Small letters
1 0
Ordinary lettering
1 1
36
1
FAX Mexican legal, 
foolscap threshold value 
Enable/Disable setting
1: Disable
0: Enable
0
0:  Enable
2
FAX Mexican legal, legal 
threshold value Enable/
Disable setting
1: Disable
0: Enable
0
0: Enable
3 - 7
Not used
0
0
0
1
0
8
Confirmation of DIS 
reception when sending
1: Twice
0: Once for NFS 
reception, twice for 
DIS reception
0
Enable for other 
than V.34
SW 
No.
Bit 
No.
System 
settings
Item
SW selection and function
Initial value
Remarks
MX-M1100  SIMULATION  7 – 84
37
1 - 7
Not used
0
1
0
1
1
0
0
8
FAX receive 
setting
Diagonal staple setting
1: Staple direction: 
diagonal
0: Staple direction: 
parallel
0
0: Staple direction: 
parallel
Enable when 
SW22-4 - 5 is set to 
"Behind one 
position."
SW22-4 - 5 
variation name 
(staple Position)
38
1, 2
Protocol monitor
No
0 0
0
No
Yes
1 0
0
Only at times of error
1 1
3
Line monitor display
1: Yes
0: No
0
No
4
EEPROM access prohibited
1: Access prohibited
0: Access permitted
0
Access permitted
5
Not used
0
6
SDT signal detection
1: Yes
0: No
0
No
7, 8
Timer setting (V.21-FSK) 
between flag-adrs
6 seconds
0 0
0
20 seconds
Enable for other 
than V.34
20 seconds
0 1
1
30 seconds
1 0
120 seconds
1 1
39
1
Echo countermeasure (CED 
tone sending interval) when 
receiving
1: 500ms
0: 75ms
1
500ms
2
Echo countermeasure 
(setting of hold time 
between DIS reception and 
sending of signal) when 
transmitting
1: 800ms
0: 500ms
0
500ms
Enable for other 
than V.34
3 - 6
Not used
0
0
0
1
7, 8
RTN sending line error rate
6line
0 0
1
60line
Number of error 
lines in the STD 
standard
12line
0 1
0
60line
1 0
120line
1 1
40
1
CSI sending
1: No
0: Yes
0
Yes
2, 3
CED signal sending time
3 seconds
0 0
0
3 seconds
Setting for the 
ANSam signal is 
performed using a 
separate SW 51-7, 
8 (V.8 mode 
ANSam signal 
sending time).
4 seconds
0 1
0
5 seconds
1 0
No
1 1
4
CED/ANSam detection time
1: 1000ms
0: 500ms
1
1000ms
5, 6
Waiting time for start of 
CED/ANSam sending
2.25 seconds
0 0
0
2.25 seconds
3 seconds
0 1
0
4 seconds
1 0
7, 8
Not used
0
0
41
1, 2
Start of CNG sending
0.5 seconds
0 0
"11": 2.0 seconds 
(North America/
Taiwan/Middle East/
Other3/Rusia)
"00": 0.5 seconds 
(Other country)
1.0 seconds
0 1
1.5 seconds
1 0
2.0 seconds
1 1
3
Time between DCS-TCF
1: 150ms
0: 75ms
0
75ms
4 - 8
Not used
0
1
0
0
0
SW 
No.
Bit 
No.
System 
settings
Item
SW selection and function
Initial value
Remarks
Page of 103
Display