MX-M1100  SIMULATION  7 – 69
 
65
 
65-1
Purpose
Adjustment
Function (Purpose) Used to adjust the detection position of the
touch panel (LCD display section).
Section
Operation panel section
Operation/Procedure
Touch the centers of the four cross marks on the screen.
When all the four points are touched and OK, the corrected value of
sampling is saved.
 
65-2
Purpose
Operation check/Test
Function (Purpose) Used to check the result of the touch panel
(LCD display section) detection position
adjustment.
Section
Operation panel section
Operation/Procedure
Touch the touch panel. 
The coordinates X (horizontal) and Y (vertical) of the current touch
position are displayed in real time.
 
65-5
Purpose
Operation check/Test
Function (Purpose) Used to check the key input of the opera-
tion panel.
Section
Operation panel section
Operation/Procedure
Press the keys displayed on the screen sequentially.
 
66
 
66-1
Purpose
Setting
Function (Purpose) Used to change and check the soft switch
setting.
Section
Operation/Procedure
1)
Press [SW No.] key.
2)
Enter the soft switch number to be checked or changed with
10-key.
3)
Press [DATA] key.
The current setting status is displayed.
4)
Enter the number corresponding to the BIT to be changed with
10-key.
For details, refer to "4-A. Soft switches."
5)
Press [EXECUTE] key.
The setting content is saved.
 
66-2
Purpose
Data clear
Function (Purpose) Used to clear the soft switch and set the
default value.
Section
FAX
Operation/Procedure
1)
Enter the country code with 10-key.
* When [DEST CODE] key is pressed, the country code list is
displayed.
When [BACK] key is pressed on the destination code list
screen, the display returns to the destination code entry
screen.
2)
Press [SET] key.
3)
Press [EXECUTE] key.
4)
Press [YES] key.
Clearing the soft switch is executed.
 
66-3
Purpose
Operation test, check
Function (Purpose) Used to check the operation (read/write) of
the FAX PWB memory. 
Section
FAX
Operation/Procedure
1)
Select a target item of the memory operation check with the
touch panel.
2)
Press [EXECUTE] key.
The operation check of the selected memory is executed.
If "(once)" is selected, when check is completed normally, "OK"
is displayed. When there occurs an error, "NG" is displayed.
If "(repeat)" is selected, check is repeated until the result is
found "NG" or until [EXECUTE] key is pressed.
D
PAPER
MFT
Paper 
feed 
tray 
selec
tion
Manual 
feed 
1 - 8
1
(CS1)
CS1
Cassette 1
2
CS2
Cassette 2
3
CS3
Cassette 3
4
CS4
Cassette 4
5
LCC1
LCC1
6
LCC2
LCC2
7
LCC3
LCC3
8
E
HALF
TONE
600 
✕ 600 
dpi
half 
tone
600 
✕ 600 
dpi
0 - 1
0
0
1200 
✕ 
1200 dpi
1200 
✕ 
1200 dpi
1
Item
Display item & 
detail display
Item description
Setting 
range
Defaul
t value
JAPAN
0 0 0 0 0 0 0 0
SWITZERLAND  1 0 1 0 0 11 0
U.S.A
1 0 11 0 1 0 1
AUSTRIA
0 0 0 0 1 0 1 0
AUSTRALIA
0 0 0 0 1 0 0 1
INDONESIA
0 1 0 1 0 1 0 0
U.K
1 0 11 0 1 0 0
THAILAND
1 0 1 0 1 0 0 1
FRANCE
0 0 1111 0 1
MALAYSIA
0 11 0 11 0 0
GERMANY
0 0 0 0 0 1 0 0
INDIA
0 1 0 1 0 0 11
SWEDEN
1 0 1 0 0 1 0 1
PHILIPPINES
1 0 0 0 1 0 0 1
NEW  ZEALAND
0 111111 0
HONGKONG
0 1 0 1 0 0 0 0
CHINA
0 0 1 0 0 11 0
RUSSIA
1 0 111 0 0 0
SINGAPORE
1 0 0 111 0 0
SOUTH AFRICA 
1 0 0 11111
TW
1111111 0
SPAIN
1 0 1 0 0 0 0 0
MIDDLE AND 
NEAR EAST
111111 0 1
PORTUGUESE 
1 0 0 0 1 0 11
SLOVAKIA
111111 0 0
LUXEMBURG
0 11 0 1 0 0 1
OTHER3
11111 011
BELGIUM
0 0 0 0 1111
FINLAND
0 0 11110 0
CZECH
0 0 1 0 111 0
NORWAY
10 0 0 0 0 1 0
HUNGARY
0 1 0 1 0 0 0 1
DENMARK
0 0 11 0 0 0 1
GREECE
0 1 0 0 0 11 0
NETHERLANDS
0 1111 0 11
POLAND
1 0 0 0 1 0 1 0
ITALY
0 1 0 11 0 0 1
1
All Memory Device Check (once)
Check all the items once.
2
MFP SRAM (once)
Check only once.
3
MFP SRAM (repeat)
Repeat checking.
4
MFP FLASH + OP.FLASH (once)
Check only once.
5
MFP FLASH + OP.FLASH(repeat)
Repeat checking.
6
MODEM EEPROM<1>(once)
Check only once.
7
MODEM EEPROM<1>(repeat)
Repeat checking.
8
MODEM SDRAM<1>(once)
Check only once.
9
MODEM SDRAM<1>(repeat)
Repeat checking.
MX-M1100  SIMULATION  7 – 70
 
66-4
Purpose
Operation test, check
Function (Purpose) Used to check the output operation
(MODEM operation) of data signal in each
data output mode of FAX. Send level: MAX
Section
FAX
Operation/Procedure
1)
Select the display screen with [
↑] and [↓] keys.
2)
Select an output target mode with the touch panel key.
3)
Press [EXECUTE] key.
A signal is outputted at the maximum send level.
When [EXECUTE] key is pressed, the signal output can be
stopped.
 
66-5
Purpose
Operation test, check
Function (Purpose) Used to check the output operation of data
signal in each data output mode of
FAX(MODEM operation). Send level: Soft
switch setting
Section
FAX
Operation/Procedure
1)
Select the display screen with [
↑] and [↓] keys.
2)
Select an output target mode with the touch panel key.
3)
Press [EXECUTE] key.
A signal is outputted at the send level set with the soft switch.
When [EXECUTE] key is pressed, the signal output can be
stopped.
 
66-6
Purpose
User data output, check
Function (Purpose) Used to print the confidential pass code.
Section
FAX
Operation/Procedure
Press [EXECUTE] key to execute printing.
* If there is no confidential registration, no print is made.
 
66-7
Purpose
User data output, check
Function (Purpose) Used to output the image memory data
(memory send and receive).
* The confidential receive contents are also
outputted.
Section
FAX
Operation/Procedure
Press [EXECUTE] key to execute printing.
* If there is no image memory, no output is made.
 
66-8
Purpose
Operation test, check
Function (Purpose) Used to check the output operation (audio
output IC operation check) of the various
audio signals of FAX. Send level: MAX
Section
FAX
Operation/Procedure
1)
Select an output target model with the touch panel key.
2)
Press [EXECUTE] key.
A signal is outputted at the maximum send level.
When [EXECUTE] key is pressed, the signal output can be
stopped.
 
66-9
Purpose
Operation test, check
Function (Purpose) Used to check the output operation of vari-
ous audio signals of FAX (audio output IC
operation). Send level: Soft switch setting
Section
FAX
Operation/Procedure
1)
Select an output target mode with the touch panel key.
2)
Press [EXECUTE] key.
A signal is outputted at the send level set with the soft switch.
When [EXECUTE] key is pressed, the signal output can be
stopped.
NOSIGNAL
33.6 V34
31.2 V34
28.8 V34
26.4 V34
24.0 V34
21.6 V34
19.2 V34
16.8 V34
14.4 V34
12.0 V34
9.6 V34
7.2 V34
4.8 V34
2.4 V34
14.4 V33
12.0 V33
14.4 V17
12.0 V17
9.6 V17
7.2 V17
9.6 V29
7.2 V29
4.8 V27t 
2.4 V27t
0.3 FLG
CED 2100
CNG 1100
0.3 V21
ANSam
RINGER
No RBT
DP MAKE
DP BRK
No MSG
NOSIGNAL
33.6 V34
31.2 V34
28.8 V34
26.4 V34
24.0 V34
21.6 V34
19.2 V34
16.8 V34
14.4 V34
12.0 V34
9.6 V34
7.2 V34
4.8 V34
2.4 V34
14.4 V33
12.0 V33
14.4 V17
12.0 V17
9.6 V17
7.2 V17
9.6 V29
7.2 V29
4.8 V27t 
2.4 V27t
0.3 FLG
CED 2100
CNG 1100
0.3 V21
ANSam
RINGER
No RBT
DP MAKE
DP BRK
No MSG
NONE
Mute
PAUSE
Pause melody
MESSAGE1
Message 1
MESSAGE2
Message 2
MESSAGE3
Message 3
MESSAGE4
Message 4
MESSAGE5
Message 5
MESSAGE6
Message 6
ALARM
Alarm
RINGER
Ringer (Speaker)
EXT.TEL.RINGER
External telephone ringer
NONE
Mute
PAUSE
Pause melody
MESSAGE1
Message 1
MESSAGE2
Message 2
MESSAGE3
Message 3
MESSAGE4
Message 4
MESSAGE5
Message 5
MESSAGE6
Message 6
ALARM
Alarm
RINGER
Ringer (Speaker)
EXT.TEL.RINGER
External telephone ringer
MX-M1100  SIMULATION  7 – 71
 
66-10
Purpose
Data clear
Function (Purpose) Used to clear all the data (memory receive
and send) of the image memory.
* The confidential receive data are cleared
simultaneously.
Section
FAX
Operation/Procedure
1)
Press [EXECUTE] key.
2)
Press [YES] key.
The image memory is cleared.
 
66-11
Purpose
Operation test, check
Function (Purpose) Used to check the output operation in the
FAX G3 mode 300bps (MODEM operation).
Send level: MAX
Section
FAX
Operation/Procedure
1)
Select an output target mode with the touch panel key.
2)
Press [EXECUTE] key.
A signal is outputted at the maximum send level.
When [EXECUTE] key is pressed, the signal output can be
stopped.
 
66-12
Purpose
Operation test, check
Function (Purpose) Used to check the output operation in the
FAX G3 mode 300bps (MODEM operation).
Send level: Set with the soft switch.
Section
FAX
Operation/Procedure
1)
Select an output target mode with the touch panel.
2)
Press [EXECUTE] key.
A signal is outputted at the send level set with the soft switch.
When [EXECUTE] key is pressed, the signal output can be
stopped.
 
66-13
Purpose
Setting
Function (Purpose) Used to set the number for the FAX dial sig-
nal output test. (In the dial signal output test
with Sim. 66-14 - 16, the dial number set 
with this simulation is outputted.)
Section
FAX
Operation/Procedure
1)
Enter the set value with 10-key.
Enter with 10-key (0 - 9), [*] key,  and [#] key. One previous
character is deleted by [C] key. The upper limit is 20 digits.
2)
Press [SET] key.
Setting is saved.
 
66-14
Purpose
Setting/Operation test, check
Function (Purpose) Used to set the make time in the FAX pulse
dial mode (10PPS) and to execute the dial
signal output test. (The signal of the dial
number set with Sim. 66-13 is outputted.)
Section
FAX
Operation/Procedure
1)
Enter the set value of make time with 10-key. (0 - 15)
2)
Press [EXECUTE] key.
The dial signal is outputted at the make time set with the above
procedure.
When [EXECUTE] key is pressed, the signal output can be
stopped.
 
66-15
Purpose
Setting/Operation test, check
Function (Purpose) Used to set the make time in the FAX pulse
dial mode (20PPS) and to execute the dial
signal output test. (The signal of the dial
number set with Sim. 66-13  is outputted.)
Section
FAX
Operation/Procedure
1)
Enter the set value of the make time with 10-key. (0 - 15)
2)
Press [EXECUTE] key.
The dial signal is outputted at the make time set in the above
procedure.
When [EXECUTE] key is pressed, the signal output can be
stopped.
 
66-16
Purpose
Setting/Operation test, check
Function (Purpose) Used to perform the dial signal (DTMF) out-
put test in the FAX tone dial mode. (The
signal of the dial number set with Sim. 66-
13 is outputted.) The send level can be set
to an optional level.
Section
FAX
Operation/Procedure
1)
Select a target item to be set with [
↑] [↓] keys.
2)
Enter the set value of the send level with 10-key. (0 - 15)
3)
Press [EXECUTE] key.
The dial signal is outputted at the send level set in the above
procedure.
When [EXECUTE] key is pressed, the signal output can be
stopped.
 
66-17
Purpose
Operation test, check
Function (Purpose) Used to perform the dial signal (DTMF) out-
put test in the FAX tone dial mode. Send
level: MAX
Section
FAX
Operation/Procedure
1)
Select an output target mode with the touch panel.
2)
Press [EXECUTE] key.
A signal is outputted at the maximum send level.
When [EXECUTE] key is pressed, the signal output can be
stopped.
 
66-18
Purpose
Operation test, check
Function (Purpose) Used to perform the dial signal (DTMF) out-
put test in the FAX tone dial mode. Send
level: Set with the soft switch.
Section
FAX
Operation/Procedure
1)
Select an output target mode with the touch panel.
2)
Press [EXECUTE] key.
A signal is outputted at the send level set with the soft switch.
When [EXECUTE] key is pressed, the signal output can be
stopped.
MX-M1100  SIMULATION  7 – 72
 
66-21
Purpose
Adjustment, setting, operation data check
Function (Purpose) Used to print information abut FAX (various
registrations, communication manage-
ment, file management, system errors, pro-
tocols).
Section
FAX
Operation/Procedure
1)
Select a print target item with the touch panel key.
2)
Press [EXECUTE] key.
Printing is started.
 
66-22
Purpose
Adjustment/ Setting
Function (Purpose) Used to adjust the handset sound volume
Section
Operation/Procedure
1)
Adjust the handset sound volume with 10-key.
2)
Press [OK] key.
The set value is saved.
When [EXECUTE] key is pressed, the selected delivery sound
is sent.
 
66-24
Purpose
Clear
Function (Purpose) Used to clear the FAST memory data.
Section
FAX
Operation/Procedure
1)
Press [EXECUTE] key.
2)
Press [YES] key.
The FAST memory data are cleared.
 
66-25
Purpose
Setting
Function (Purpose) Used to register a FAX number for MODEM
dial-in.
Section
FAX
Operation/Procedure
1)
Enter a MODEM dial-in FAX number (0 - 9, *, #) with 10-key.
The upper limit is 20 digits.
2)
Press [SET] key.
The MODEM dial-in FAX number is registered.
 
66-26
Purpose
Setting
Function (Purpose) Used to register an external telephone
number for MODEM dial-in.
Section
FAX
Operation/Procedure
1)
Enter a MODEM dial-in external telephone number (0 - 9, *, #)
with 10-key. One previous character is deleted by [C] key. The
upper limit is 20 digits.
2)
Press [SET] key.
The MODEM dial-in external telephone number is registered.
 
66-29
Purpose
Data clear
Function (Purpose) Used to clear the data related to the
address book (one-touch registration, FTP/
Desktop extension, group extension, pro-
gram registration, interface memory box,
meta data, Inbound Routing, Document
Admin table).
Section
Operation/Procedure
1)
Press [EXECUTE] key.
2)
Press [YES] key.
The data related to the address book are cleared.
 
66-30
Purpose
Operation test, check
Function (Purpose) Used to check a change in the TEL/LIU sta-
tus.
Section
FAX
Operation/Procedure
The TEL/LIU status is displayed.
(Signal detected: Highlighted display, Signal not-detected: Normal
display)
 
66-31
Purpose
Operation check
Function (Purpose) Used to set the TEL/LIU output port.
Section
FAX
Operation/Procedure
1)
Select the port to be turned ON with the touch panel key. 
(ON: Highlighted display)
2)
Press [EXECUTE] key.
The setting is reflected.
When [EXECUTE] key is pressed, the operation can be
stopped.
 
66-32
Purpose
Operation test, check
Function (Purpose) Used to check the received data (fixed
data) from the line.
Section
FAX
Operation/Procedure
1)
Press [EXECUTE] key.
The fixed data received from the line are checked.
2)
When the check is completed normally, "OK" is displayed.
When an error occurs, "NG" is displayed.
When [EXECUTE] key is pressed, the operation can be
stopped.
 
66-33
Purpose
Operation test, check
Function (Purpose) Used to detect the line signals (BUSY
TONE/CNG/CED/FNET/DTMF).
Section
FAX
Operation/Procedure
Select a target item for signal detection check with the touch panel
key.
The detected signal is highlighted.
0
MIN
1
MIDDLE
2
MAX
HS1
Polarity reversal signal
HS2
Polarity reversal signal
RHS
Handset hook SW
EXHS
External telephone hook SW