Sharp MX-M850 (serv.man37) Service Manual ▷ View online
MX-M1100 SIMULATION 7 – 89
60
1
No. 2 dial tone detection
1: YES
0: NO
0
NO
Support from BOX
Veer 01.03
Veer 01.03
2 - 8
Not used
0
0
0
0
0
0
0
0
0
0
0
0
0
61
1 - 8
Adjustment
value
value
Setting of DTMF minimum
pause time
pause time
Setting range
Binary input
Binary input
50 to 255ms
1ms intervals
1ms intervals
0
120ms
1
1
1
1
0
0
0
1
1
1
0
0
0
62
1 - 5
DTMF signal send time
Setting range
Binary input
Binary input
70 to 310ms
10ms intervals
10ms intervals
0
110ms
When set to "69ms
or below," the
default value of
"110ms" is set.
or below," the
default value of
"110ms" is set.
1
0
1
1
0
1
1
6
Not used
"0": North America/Australia/China/
Singapore/Indonesia/Thailand/Malaysia/
India/Philippine/Hong Kong/Taiwan/
Middle East/Other3/Rusia
"1": Other country
Singapore/Indonesia/Thailand/Malaysia/
India/Philippine/Hong Kong/Taiwan/
Middle East/Other3/Rusia
"1": Other country
7
DPMUTE control
1: ON
0: OFF
0
OFF
Functions only in
Australia, New
Zealand, U.K.,
France, Germany,
Sweden.
Australia, New
Zealand, U.K.,
France, Germany,
Sweden.
8
Busy tone OFF non-
detection time
detection time
1: 300ms
0: 100ms
0
100ms
Make shorter than
the "busy tone OFF
detection time."
the "busy tone OFF
detection time."
63
1, 2
Lower limit of busy tone ON
detection time
detection time
250ms
0 0
"00": 250ms (North
America/Australia/
New Zealand/China/
Singapore/Indonesia/
Thailand/Malaysia/
India/Philippine/
Hong Kong/Taiwan/
Middle East/Other3/
South Africa)
"01": 140ms
(Other country)
America/Australia/
New Zealand/China/
Singapore/Indonesia/
Thailand/Malaysia/
India/Philippine/
Hong Kong/Taiwan/
Middle East/Other3/
South Africa)
"01": 140ms
(Other country)
140ms
0 1
450ms
1 0
350ms
1 1
3, 4
Upper limit of busy tone ON
detection time
detection time
750ms
0 0
"10": 1000ms
(Australia/India)
"11": 2850ms
(Singapore/South
Africa)
"00": 750ms
(Other country)
(Australia/India)
"11": 2850ms
(Singapore/South
Africa)
"00": 750ms
(Other country)
650ms
0 1
1000ms
1 0
2850ms
1 1
5, 6
Lower limit of busy tone
OFF detection time
OFF detection time
250ms
0 0
"00": 250ms (North
America/Australia/
New Zealand/China/
Singapore/Indonesia/
Thailand/Malaysia/
India/Philippine/
Hong Kong/Taiwan/
Middle East/Other3/
South Africa)
"01": 140ms
(Other country)
America/Australia/
New Zealand/China/
Singapore/Indonesia/
Thailand/Malaysia/
India/Philippine/
Hong Kong/Taiwan/
Middle East/Other3/
South Africa)
"01": 140ms
(Other country)
140ms
0 1
450ms
1 0
350ms
1 1
7, 8
Upper limit of busy tone
OFF detection time
OFF detection time
750ms
0 0
"10": 1000ms
(Singapore/India/
South Africa)
"00": 750ms
(Other country)
(Singapore/India/
South Africa)
"00": 750ms
(Other country)
650ms
0 1
1000ms
1 0
2850ms
1 1
SW
No.
No.
Bit
No.
System
settings
Item
SW selection and function
Initial value
Remarks
MX-M1100 SIMULATION 7 – 90
64
1 - 4
Not used
0
0
0
0
0
0
0
5 - 8
Call signal OFF non-
detection time
detection time
Setting range
Binary input
Binary input
0 to 1500ms
100ms intervals
100ms intervals
"0110": 600ms (North
America/Australia/
Taiwan/Middle East/
Other3/Rusia)
"1010": 1000ms
(New Zealand)
"0100": 400ms
(Other country)
America/Australia/
Taiwan/Middle East/
Other3/Rusia)
"1010": 1000ms
(New Zealand)
"0100": 400ms
(Other country)
65
1 - 4
Lower limit of call signal ON
time
time
Setting range
Binary input
Binary input
150ms to 300ms
10ms intervals
10ms intervals
"0010": 170ms
(Australia)
"0000": 150ms
(Other country)
(Australia)
"0000": 150ms
(Other country)
5 - 8
Upper limit of call signal ON
time
time
Setting range
Binary input
Binary input
3000ms to 4500ms
100ms intervals
100ms intervals
0
3000ms
0
0
0
0
0
66
1 - 4
Lower limit of call signal
OFF time
OFF time
Setting range
Binary input
Binary input
0 to 1500ms
100ms intervals
100ms intervals
0
700ms
When set to "0000,"
the default value is
set.
the default value is
set.
1
1
1
1
1
5, 6
Upper limit of call signal
OFF time
OFF time
6.5 seconds
0 0
"01": 10 seconds
(Sweden/Indonesia)
"00": 6.5 seconds
(Other country)
(Sweden/Indonesia)
"00": 6.5 seconds
(Other country)
10 seconds
0 1
15 seconds
1 0
20 seconds
1 1
7, 8
Not used
0
0
0
67
1 - 8
Not used
0
1
0
1
0
1
1
0
1
0
1
0
1
1
0
68
1 - 8
Not used
0
0
0
0
1
1
0
1
0
0
0
1
1
0
1
69
1 - 8
Not used
0
70
1 - 4
Not used
0
0
0
0
0
0
0
5
Manual calibration setting
when sending
when sending
1: Not execute
0: Execute
0
Execute
6
Manual calibration setting
when a signal arrives
when a signal arrives
1: Not execute
0: Execute
0
Execute
7, 8
Not used
0
0
0
71
1, 2
Reception/
forwarding
setting
forwarding
setting
Reception mode setting
Automatic reception
0 0
1
Automatic
reception
reception
Setting can be
made even without
the external
telephone.
made even without
the external
telephone.
Manual reception
0 1
1
Answerphone
connection
connection
1 0
3, 4
Image capacity when
receiving
(Reflect in DIS, Do not
reflect in DTC)
receiving
(Reflect in DIS, Do not
reflect in DTC)
Very fine
0 0
0
Very fine
Fine
0 1
0
When small
1 0
Ordinary lettering
1 1
5, 6
Designation of reception
size (indicating the width of
reception capacity)
size (indicating the width of
reception capacity)
By loaded cassette
0 0
1
By loaded
cassette
cassette
Fax printing with
max. size according
to existing cassette
A3 or A4
max. size according
to existing cassette
A3 or A4
→ A3
B4 or B5
→ B4
A4
0 1
1
B4 (B4, A4)
1 0
A3 (A3, B4, A4)
1 1
7, 8
Not used
0
0
0
SW
No.
No.
Bit
No.
System
settings
Item
SW selection and function
Initial value
Remarks
MX-M1100 SIMULATION 7 – 91
72
1
Report output (when
cancelled)
cancelled)
1: Output
0: Do not output
0
Do not output
2
Report output (when
refusing reception)
<FAX only>
refusing reception)
<FAX only>
1: Output
0: Do not output
0
Do not output
Internet Fax is set
by means of
SW155-8.
Irrespective of
"Always print" and
"Error," the results
sheet is not printed.
by means of
SW155-8.
Irrespective of
"Always print" and
"Error," the results
sheet is not printed.
3
Printing of transmitted
document contents at times
of F code communication
<FAX only>
document contents at times
of F code communication
<FAX only>
1: Print
0: Do not print
0
Do not print
The "Document
contents printing
(results sheet) at
times of
transmission"
setting takes
priority.
contents printing
(results sheet) at
times of
transmission"
setting takes
priority.
4
Not used
0
5
Designation of rotation
direction when printing on
both sides and the rear side
direction when printing on
both sides and the rear side
1: Vertical binding
0: Horizontal binding
0
Horizontal binding
6
Selection of error page
output when error occurs
during FAX reception
output when error occurs
during FAX reception
1: Do not output the
error page
error page
0: Output the error page
0
Output the error
page
page
7
Selection of re-send page at
times of error
times of error
1: All pages
0: Error page and
onwards
onwards
0
Error page and
onwards
onwards
The F code is
compulsorily resent
to all pages.
compulsorily resent
to all pages.
8
Relay data output
1: No
0: Yes
0
Yes
73
1
Not used
0
2
F code communication error
handling
handling
1: Do not re-send
0: Re-send
0
Re-send
Only when the
remote machine
function is enable.
remote machine
function is enable.
3
F code password
transmission setting when
the other party's machine
has no password capacity
transmission setting when
the other party's machine
has no password capacity
1: Send with password
0: Disconnect with DCN
0
Disconnect with
DCN
DCN
4
Remaining receivable
memory
memory
1: 64KB
0: 128KB
0
128KB
5
Setting of received
document output when
receiving
document output when
receiving
1: Output 1 page at a
time
time
0: Save and output en
masse following
completion of reception
masse following
completion of reception
0
Save and output
en masse
following
completion of
reception
en masse
following
completion of
reception
6, 7
Not used
0
0
0
8
Rotated printing
1: Prohibited
0: Permitted
0
Permitted
74
1 - 4
Magnification setting in
automatic reduction
automatic reduction
Setting range
Binary input
Binary input
85% to 100%
N x 1% + 85%
N x 1% + 85%
0
90%
1
0
1
0
1
5
Determination of sub-scan
length (determination
setting when selecting the
page)
length (determination
setting when selecting the
page)
1: Priority to data width
0: Priority to data length
0
Priority to data
length
length
6
Setting of protocol monitor
print when setting offset
staple
print when setting offset
staple
1: Offset or staple
0: No offset or No staple
0
No offset or No
staple
staple
7, 8
Not used
0
0
0
75
1 - 8
Not used
0
76
1 - 8
Not used
0
0
0
0
1
0
1
0
0
0
0
1
0
1
0
SW
No.
No.
Bit
No.
System
settings
Item
SW selection and function
Initial value
Remarks
MX-M1100 SIMULATION 7 – 92
77
1
Setting of the reception
width of 11 x 17 sheet
width of 11 x 17 sheet
1: B4 width (B4, A4)
0: A3 width (A3, B4, A4)
0
A3 width
2
Not used
0
3
Operation
settings
settings
Saving the setting contents
for a certain period after
completion of scanning
for a certain period after
completion of scanning
1: The set values are
saved
saved
0: The set values are not
saved
saved
0
The set values are
not saved
not saved
4
Setting of communication
error sound when there is
no response from the other
party in FAX reception
error sound when there is
no response from the other
party in FAX reception
1: Error sound
0: No error sound
0
No error sound
Valid in cases
except when the
communication
error completion
sound setting is
OFF.
except when the
communication
error completion
sound setting is
OFF.
5
Re-transmission at times of
no response from the other
party
no response from the other
party
1: Do not re-call
0: Re-call
0
Re-call
6 - 8
Not used
0
0
0
0
0
78
1
Setting to refuse reception
at times of manual
reception (FAX)
at times of manual
reception (FAX)
1: Specified number
reception rejection
reception rejection
0: Specified number
reception ignoring (OFF)
reception ignoring (OFF)
0
Specified number
reception ignoring
reception ignoring
Only valid in cases
where the
designated number
reception refusal
setting (FAX) is
refused.
where the
designated number
reception refusal
setting (FAX) is
refused.
2
TSI judgment setting (no
signal or all space) when
refusing reception from
designated numbers
signal or all space) when
refusing reception from
designated numbers
1: Reception will be
refused
refused
0: Reception will be
permitted
permitted
0
Reception will be
permitted
permitted
Only valid in cases
where the
designated number
reception refusal
setting (FAX) is
refused.
where the
designated number
reception refusal
setting (FAX) is
refused.
3
TSI judgment setting (No
numbers and no space can
be used)
numbers and no space can
be used)
1: Reception will be
refused
refused
0: Reception will be
permitted
permitted
0
Reception will be
permitted
permitted
Only valid in cases
where the
designated number
reception refusal
setting (FAX) is
refused.
where the
designated number
reception refusal
setting (FAX) is
refused.
4
Not used
0
5, 6
Number of dial call pages at
times of quick online
transmission
times of quick online
transmission
1 page
0 0
0
1 page
1 page
0 1
0
2 pages
1 0
3 pages
1 1
7
Paper select when receive
printing (LTR/A4)
printing (LTR/A4)
1: LTR priority
0: LTR/A4 reduction rate
priority
priority
0
LTR/A4 reduction
rate priority
rate priority
8
Not used
0
79
|
80
1 - 8
Not used
0
81
1 - 8
Not used
0
0
0
0
0
0
1
1
0
0
0
0
0
1
1
82
1 - 8
Not used
"00000100": North America/China/Thailand/
Malaysia/Philippine/Taiwan/Rusia
"00001000": Singapore/Indonesia/India/
Hong Kong/Middle East
"00100100": Other3
"00101000": New Zealand/South Africa
"01100100": Australia
"00101100": Other country
Malaysia/Philippine/Taiwan/Rusia
"00001000": Singapore/Indonesia/India/
Hong Kong/Middle East
"00100100": Other3
"00101000": New Zealand/South Africa
"01100100": Australia
"00101100": Other country
83
1 - 8
Not used
"00000000": North America/Australia/
New Zealand/China/Singapore/Indonesia/
Thailand/Malaysia/India/Philippine/Hong
Kong/Taiwan/Middle East/Rusia/South Africa
"00010000": Other country
New Zealand/China/Singapore/Indonesia/
Thailand/Malaysia/India/Philippine/Hong
Kong/Taiwan/Middle East/Rusia/South Africa
"00010000": Other country
SW
No.
No.
Bit
No.
System
settings
Item
SW selection and function
Initial value
Remarks
Click on the first or last page to see other MX-M850 (serv.man37) service manuals if exist.