DOWNLOAD Sharp MX-M623U / MX-M753U (serv.man10) Service Manual ↓ Size: 49.81 MB | Pages: 127 in PDF or view online for FREE

Model
MX-M623U MX-M753U (serv.man10)
Pages
127
Size
49.81 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / COMPLETE SERVICE MANUAL
File
mx-m623u-mx-m753u-sm10.pdf
Date

Sharp MX-M623U / MX-M753U (serv.man10) Service Manual ▷ View online

MX-M753N  SIMULATION  6 – 31
NOTE: The set value may be changed for a design change or an individual arrangement. Except for the above cases, however, the set value
must not be changed. If it is changed, a trouble may be occur.
<Code descriptions>
<List of destination groups>
 
43-4
Purpose
Setting
Function (Purpose) Used to set the fusing temperature 2 in
each operation mode.
Section
Operation/Procedure
1)
Select an item to be set with [
] [] keys.
2)
Enter the set value with 10-key.
3)
Press [OK] key.
The set value in step 2) is saved.
NOTE: The set value may be changed for a design change or an
individual arrangement. Except for the above cases, how-
ever, the set value must not be changed. If it is changed, a
trouble may be occur.
Item
Display
Content
Setting 
range
Default value
Group A
Group B
Group C
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
A
HL_UM READY
TH_UM set value when ready standby
70 - 240
200
205
200
205
200
205
B
HL_US READY
TH_US set value when ready standby
70 - 240
200
205
200
205
200
205
C
HL_UM PLAIN PAPER BW
Black and white plain paper TH_UM set value
70 - 240
200
205
210
210
D
HL_US PLAIN PAPER BW
Black and white plain paper TH_US set value
70 - 240
200
205
210
210
E
WARMUP FUMON HL_UM T
Fusing motor previous rotation start TH_UM set value
30 - 240
190
50
50
F
WARMUP FUMOFF HL_UM T
Fusing motor previous rotation complete time
0 - 200
5
G
WARM UP END TIME
Warm-up complete time
0 - 200
28
50
28
50
28
50
H
HL_UM HEAVY PAPER
Heavy paper TH_UM set value
70 - 240
220
I
HL_US HEAVY PAPER
Heavy paper TH_US set value
70 - 240
220
J
HL_UM OHP PAPER
OHP-TH_UM set value
70 - 240
210
K
HL_US OHP PAPER
OHP-TH_US set value
70 - 240
210
L
HL_UM E-STAR
Preheating TH_UM set value
30 - 200
165
M
HL_US E-STAR 
Preheating TH_US set value
30 - 200
165
N
PRE-JOB
Resetting from preheating TH_UM set value
30 - 240
180
190
190
O
HL_UM WARMUP_120L
TH_UM set value when warming up of 120
C or less
70 - 240
200
210
215
215
P
HL_US WARMUP_120L
TH_US set value when warming up of 120
C or less
70 - 240
200
210
215
215
Q
LO_WARMUP_TIME 
O - P applying time (Timer from completion of Ready)
0 - 255
5
R
HL_UM WARMUP_120H
TH_UM set value when warming up of 120
C or above
70 - 240
200
210
215
215
S
HL_US WARMUP_120H
TH_US set value when warming up of 120
C or above
70 - 240
200
210
215
215
T
HI_WARMUP_TIME
R - S applying time (Timer from completion of Ready)
0 - 255
5
U
HI_WU_FM_ON_TMP
FM previous rotation start TH_US set value when 
warming up of alpha 
C or above
30 - 240
130
V
HI _WU_END_TIME
Warm-Up complete time when warming up of alpha 
C 
or above
0 - 200
28
50
28
50
28
50
W
HI_WU_JOB_SET_TMP1
Job enable TH UM temperature 1 when warming up of 
alpha 
C or above
70 - 240
190
200
210
210
X
HI_WARMUP_BORDER
U - W applying set value
1 - 119
70
Y
LO_WU_JOB_SET_TMP1
Job enable TH UM temperature 1 when warming up of 
alpha 
C or less
70 - 240
190
200
210
210
Z
JOBEND_FUMON_TIME
After rotation time when Job end
0 - 200
10
AA
HI_WU_JOB_SET_TMP2
Job enable TH UM temperature 2 when warming up of 
alpha 
C or above
70 - 240
195
205
210
210
AB
LO_WU_JOB_SET_TMP2
Job enable TH UM temperature 2 when warming up of 
alpha 
C or less
70 - 240
195
205
210
210
TH_UM
Fusing upper thermistor main
HL_UM
Heater lamp upper main
TH_US
Fusing upper thermistor sub
HL_US
Heater lamp upper sub
SW-A
Setting value when 60 - 89g/m
2
SW-B
Set value when 90 - 105g/m
2
The set value displayed in this simulation differs depending on 
60 - 89g/m
2
 or 90 - 105g/m
2
(Example) When 60 - 89g/m
2
Group
Destination 
Group A
Japan
China
AB_B
Group B
U.S.A.
Canada
Inch
Group C
Europe
U.K.
AUS
AB_A
MX-M753N  SIMULATION  6 – 32
<Code descriptions>
<List of destination groups>
 
43-20
Purpose
Adjustment/Setting
Function (Purpose) Used to set the environmental correction
under low temperature and low humidity (L/
L) for the fusing temperature setting (SIM
43-1) in each paper mode.
Section
Operation/Procedure
1)
Select an item to be set with [
] [] keys.
2)
Enter the set value with 10-key.
3)
Press [OK] key.
The set value in step 2) is saved.
NOTE: The set value may be changed for a design change or an
individual arrangement. Except for the above cases, how-
ever, the set value must not be changed. If it is changed, a
trouble may be occur.
Correction value: -49 - +49, 1 Count = 1
C change/1sec change
Item
Display
Content
Setting 
range
Default value
Group A
Group B
Group C
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
A
HL_UM PLAIN PAPER BW DUP
Black and white plain paper duplex TH_UM set 
value
70 - 240
200
205
210
210
B
HL_US PLAIN PAPER BW DUP
Black and white plain paper duplex TH_US set 
value
70 - 240
200
205
210
210
C
PLAIN PAPER BW DUP APP CNT
Black and white plain paper duplex applying 
number of sheets
0 - 60
0
D
HL_UM HEAVY PAPER BW DUP
Black and white heavy paper duplex TH_UM set 
value
70 - 240
220
E
HL_US HEAVY PAPER BW DUP
Black and white heavy paper duplex TH_US set 
value
70 - 240
220
F
HEAVY PAPER BW DUP APP CNT
Black and white heavy paper duplex applying 
number of sheets
0 - 60
0
TH_UM
Fusing upper thermistor main
HL_UM
Heater lamp upper main
TH_US
Fusing upper thermistor sub
HL_US
Heater lamp upper sub
SW-A
Setting value when 60 - 89g/m
2
 is selected in the system setting/device setting/fusing control setting.
SW-B
Set value when 90 - 105g/m
2
 is selected in the system setting/device setting/fusing control setting.
The set value displayed in this simulation differs depending on 
60 - 89g/m
2
 or 90 - 105g/m
2
 which is selected in the system setting/device setting/fusing control setting.
(Example) When 60 - 89g/m
2
 is selected in the system setting/device setting/fusing control setting, the value of SW-A is displayed. 
Group
Destination 
Group A
Japan
China
AB_B
Group B
U.S.A.
Canada
Inch
Group C
Europe
U.K.
AUS
AB_A
Correction value
-49
-25
-5
0
+5
+25
+49
Input value
1
25
45
50
55
75
99
Item
Display
Content
Setting 
range
Default value
Group A
Group B
Group C
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
A
HL_UM READY LL
Correction value for TH_UM set value in ready 
standby under LL environment
1 - 99
55
60
60
B
HL_US READY LL
Correction value for TH_US set value in ready 
standby under LL environment
1 - 99
55
60
60
C
HL_UM PLAIN BW LL
Correction value for black and white plain paper 
TH_UM set value under LL environment
1 - 99
55
D
HL_US PLAIN BW LL
Correction value for black and white plain paper 
TH_US set value under LL environment
1 - 99
55
E
WARMUP FUMON HL_US T LL
Correction value for fusing motor previous rotation 
start TH_UM set value under LL environment
1 - 99
5
50
50
F
WARMUP FUMOFF T LL
Correction value for fusing motor previous rotation 
completion time under LL environment
1 - 99
50
G
WARMUP END TIME LL
Correction value for warm-up complete time under 
LL environment
1 - 99
80
H
HL_UM HEAVY LL
Correction value for heavy paper TH_UM set value 
under LL environment
1 - 99
55
I
HL_US HEAVY LL
Correction value for heavy paper TH_US set value 
under LL environment
1 - 99
55
MX-M753N  SIMULATION  6 – 33
<Code descriptions>
<List of destination groups>
J
HL_UM OHP LL
Correction value for OHP TH_UM set value under 
LL environment
1 - 99
55
K
HL_US OHP LL
Correction value for OHP TH_UM set value under 
LL environment
1 - 99
55
L
HL_UM E-STAR LL
Correction value for TH_UM set value when 
preheating under LL environment
1 - 99
55
M
HL_US E-STAR LL
Correction value for TH_US set value when 
preheating under LL environment
1 - 99
55
N
PRE-JOB LL
Correction value for TH_UM set value when 
restoring from preheating under LL environment
1 - 99
55
O
HL_UM WARMUP_120L LL
Correction value for TH_UM set value when 
warming up of 120
C or less under LL environment
1 - 99
55
60
60
P
HL_US WARMUP_120L LL
Correction value for TH_US set value when warming 
up of 120
C or less under LL environment
1 - 99
55
60
60
Q
LO_WARMUP_TIME_LL
Correction value for O - P applying time (Timer from 
Ready Complete) under LL environment
1 - 99
50
R
HL_UM WARMUP 120H LL
Correction value for TH_UM set value when 
warming up of 120
C or above under LL 
environment
1 - 99
55
60
60
S
HL_US WARMUP_120H LL
Correction value for TH_US set value when warming 
up of 120
C or above under LL environment
1 - 99
55
60
60
T
HI_WU_TIME_LL 
Correction value for R - S applying time (Timer from 
Ready Complete) under LL environment
1 - 99
50
U
HI_WU_FM_ON_TMP_LL
Correction value for FM previous rotation start 
TH_UM when warming up of alpha 
C or above 
under LL environment
1 - 99
45
V
HI_WU_END_TIME_LL
Correction value for Warm-Up complete time when 
warming up of alpha 
C or above under LL 
environment
1 - 99
50
W
HI_WU_JOB_SET_TMP_1LL
Correction value for Job enable time when warming 
up of alpha 
C or above under LL environment
1 - 99
60
X
HI_WARMUP_BORDER_LL
Correction value for the value applying U - W under 
LL environment
1 - 99
50
Y
LO_WU_JOB_SET_TMP_1LL
Correction value for Job enable TH_UM temperature 
when warming up of alpha 
C or less under LL 
environment
1 - 99
55
60
60
Z
JOBEND_FUMON_TIME_LL
Correction value for after rotation time at Job end 
under LL environment
1 - 99
50
AA
HI_WU_JOB_SET_TMP_2LL
Correction value for Job enable TH_UM temperature 
when warming up of alpha 
C or above under LL 
environment
1 - 99
60
AB
LO_WU_JOB_SET_TMP_2LL
Correction value for Job enable TH_UM temperature 
when warming up of alpha 
C or less under LL 
environment
1 - 99
60
Item
Display
Content
Setting 
range
Default value
Group A
Group B
Group C
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
TH_UM
Fusing upper thermistor main
HL_UM
Heater lamp upper main
TH_US
Fusing upper thermistor sub
HL_US
Heater lamp upper sub
SW-A
Setting value when 60 - 89g/m
2
 is selected in the system setting/device setting/fusing control setting.
SW-B
Set value when 90 - 105g/m
2
 is selected in the system setting/device setting/fusing control setting.
The set value displayed in this simulation differs depending on 
60 - 89g/m
2
 or 90 - 105g/m
2
 which is selected in the system setting/device setting/fusing control setting.
(Example) When 60 - 89g/m
2
 is selected in the system setting/device setting/fusing control setting, the value of SW-A is displayed.
Group
Destination 
Group A
Japan
China
AB_B
Group B
U.S.A.
Canada
Inch
Group C
Europe
U.K.
AUS
AB_A
MX-M753N  SIMULATION  6 – 34
 
43-21
Purpose
Adjustment/Setting
Function (Purpose) Used to set the environment correction
under high temperature and high humidity
(H/H) for the fusing temperature setting
(SIM 43-1) in each paper mode.
Section
Operation/Procedure
1)
Select an item to be set with [
] [] keys.
2)
Enter the set value with 10-key.
3)
Press [OK] key.
The set value in step 2 is saved.
NOTE: The set value may be changed for a design change or an
individual arrangement. Except for the above cases, how-
ever, the set value must not be changed. If it is changed, a
trouble may be occur.
Correction value: -49 - +49, 1 Count = 1
C change/1sec change
Correction value
-49
-25
-5
0
+5
+25
+49
Input value
1
25
45
50
55
75
99
Item
Display
Content
Setting 
range
Default value
Group A
Group B
Group C
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
A
HL_UM READY HH
Correction value for TH_UM set value in ready 
standby under HH environment
1 - 99
50
B
HL_US READY HH
Correction value for TH_US set value in ready 
standby under HH environment
1 - 99
50
C
HL_UM PLAIN BW HH
Correction value for black and white plain paper 
TH_UM set value under HH environment
1 - 99
50
D
HL_US PLAIN BW HH
Correction value for black and white plain paper 
TH_US set value under HH environment
1 - 99
50
E
WARMUP FUMON HL_UM T HH
Correction value for fusing motor previous rotation 
start TH_UM set value under HH environment
1 - 99
50
F
WARMUP FUMOFF T HH
Correction value for fusing motor previous rotation 
completion time under HH environment
1 - 99
50
G
WARMUP END TIME HH
Correction value for warm-up complete time under 
HH environment
1 - 99
50
H
HL_UM HEAVY HH
Correction value for heavy paper TH_UM set value 
under HH environment
1 - 99
50
I
HL_US HEAVY HH
Correction value for heavy paper TH_UM set value 
under HH environment
1 - 99
50
J
HL_UM OHP HH
Correction value for OHP TH_UM set value under 
HH environment
1 - 99
50
K
HL_US OHP HH
Correction value for OHP TH_US set value under 
HH environment
1 - 99
50
L
HL_UM E-STAR HH
Correction value for TH_UM set value when 
preheating under HH environment
1 - 99
50
M
HL_US E-STAR HH
Correction value for TH_US set value when 
preheating under HH environment
1 - 99
50
N
PRE-JOB HH
Correction value for TH_UM set value when 
restoring from preheating under HH environment
1 - 99
50
O
HL UM WARMUP 120L HH
Correction value for TH_UM set value when 
warming up of 120
C or less under HH 
environment
1 - 99
50
P
HL US WARMUP 120L HH
Correction value for TH_US set value when 
warming up of 120
C or less under HH 
environment
1 - 99
50
Q
LO_WARMUP_TIME_HH
Correction value for O - P applying time (Timer 
from Ready Complete) under HH environment
1 - 99
50
R
HL UM WARMUP 120H HH
Correction value for TH_UM set value when 
warming up of 120
C or above under HH 
environment
1 - 99
50
S
HL US WARMUP 120H HH 
Correction value for TH_US set value when 
warming up of 120
C or above under HH 
environment
1 - 99
50
T
HI_WU_TIME_HH
Correction value for R - S applying time (Timer from 
Ready Complete) under HH environment
1 - 99
50
U
HI_WU_FM_ON_TMP_HH
Correction value for FM previous rotation start 
TH_UM when warming up of alpha 
C or above 
under HH environment
1 - 99
50
V
HI_WU_END_TIME_HH
Correction value for Warm-Up complete time when 
warming up of alpha 
C or above under HH 
environment
1 - 99
50
Page of 127
Display

Sharp MX-M623U / MX-M753U (serv.man10) Service Manual ▷ Download