MX-M753N  SIMULATION  6 – 25
*1: 1-5sheets (20 sets) / 6-10 sheets (15 sets) / 
11-15 sheets (10 sets)
 
26-69
Purpose
Setting
Function (Purpose) Used to set the operating conditions for
toner near end.
Section
Operation/Procedure
1)
Select an item to be set with [
] [] keys.
2)
Enter the set value with 10-key.
3)
Press [OK] key.
The set value in step 2 is saved.
<List of Default values and set values for each destination>
(Contents of set items)
A: Enable/Disable setting of the toner preparation message display
when the toner remaining quantity reaches 25%.
B: Enable/Disable setting of the toner preparation message display
when the toner near end status is reached.
C: Enable/Disable setting of the machine operation when the toner
end status is reached.
For except Japan, performs operation of set value "3" regardless of
the setting value.
D: Setting of the toner supply enable time (sec) to the developer
unit after toner near end. (Range of 180 - 380 sec)
When the set time is exceeded, it is judged as toner end.
The number of output print allowed in item D is based on the
assumption that the sheets are of A4 size with print ratio of 6%.
(The number of outputs allowed differs depending on the paper
size and the print ratio.)
Set value of item D and toner supply enable time
1: 180 sec, equivalent to 2.0K sheets
2: 230 sec, equivalent to 2.5K sheets
3: 280 sec, equivalent to 3.0K sheets
4: 330 sec, equivalent to 3.5K sheets
5: 380 sec, equivalent to 4.0K sheets
* Reference value based on 6% documents
 
26-73
Purpose
Setting
Function (Purpose) Used to adjust the image loss (shade
removal amount) in the poster, the continu-
ous enlargement copy, the card scan, and
the A3 wide copy mode.
Section
Operation/Procedure
1)
Select an item to be set with [
] [] keys.
2)
Enter the set value with 10-key.
3)
Press [OK] key.
When the adjustment value is increased, the image loss
(shade delete quantity) is increased.
Item
Content
100 sheets 
binding 
finisher
4K finisher
4K saddle 
finisher
Se
t v
al
u
e
D
e
fau
lt
 val
ue
Se
t v
al
u
e
D
e
fau
lt
 val
ue
Se
t v
al
u
e
D
e
fau
lt
 val
ue
LIMIT 
SHEETS
Staple limit 
sheets
30
100
30
50
30
50
100
50
50
LIMIT 
COPIES
Staple limit 
copies ON
ON
ON
ON
ON
ON
ON
Staple limit 
copies OFF
OFF
OFF
OFF
LIMIT 
SHEETS (L)
Staple limit 
sheets
30
50
25
30
25
30
50
30
30
SADDLE 
COPIES
Saddle staple 
load quantity 
limited
ON
ON
Saddle staple 
load quantity 
not limited
OFF
Item/Display
Content
Setting 
range
Default 
value
A
TONER 
PREPARATION 
(0: YES 1: NO)
0
The toner preparation 
message is displayed.
0 - 1
1
The toner preparation 
message is not 
displayed.
B
TONER NEAR 
END 
(0: YES 1: NO)
0
The toner near end 
message is displayed.
0 - 1
0
1
The toner near end 
message is not 
displayed.
C
TONER END
1
Operation Enable in 
TONER END
1 - 3
2
2
Operation STOP in 
TONER END
3
Operation STOP in 
TONER END
D
TONER END 
COUNT
Setting of Enable/Disable of 
toner supply to the 
developer unit after toner 
near end
1 - 5
3
E
TONER E-MAIL 
ALART
0
Condition for Low 
status send of E-mail 
alert
0 - 1
1
When the toner 
preparation message 
is displayed (in near 
near toner end)
1
Condition for Low 
status send of E-mail 
alert
When near toner end
Destination
Set value
Toner preparation 
message
Toner near end message
U.S.A
0 (Displayed)
0 (Displayed)
CANADA
0 (Displayed)
0 (Displayed)
INCH
0 (Displayed)
0 (Displayed)
JAPAN
1 (Not Displayed)
0 (Displayed)
AB_B
0 (Displayed)
0 (Displayed)
EUROPE
0 (Displayed)
0 (Displayed)
U.K.
0 (Displayed)
0 (Displayed)
AUS.
0 (Displayed)
0 (Displayed)
AB_A
0 (Displayed)
0 (Displayed)
CHINA
0 (Displayed)
0 (Displayed)
Item/Display
Content
Setting 
range
Default value
A
DELETING 
SHADOW ADJ 
(M)
Rear frame side 
image loss quantity 
(shade delete 
quantity) adjustment
0 - 50
0
(Adjustment 
amount: 
0.1mm/step)
B
DELETING 
SHADOW ADJ 
(S)
Lead edge image 
loss quantity (shade 
delete quantity) 
adjustment
0 - 50
0
(Adjustment 
amount: 
0.1mm/step)
MX-M753N  SIMULATION  6 – 26
 
26-74
Purpose
Setting
Function (Purpose) Used to set the OSA trial mode.
Section
Operation/Procedure
1)
Enter the set value with 10-key.
2)
Press [OK] key.
 
26-78
Purpose
Setting
Function (Purpose) Used to set the password of the remote
operation panel mode.
Section
Operation/Procedure
1)
Enter a password with 10-key. (5 - 8 digits)
The entered password is displayed on the column of "NEW”.
In order to correct the entered password, press the [clear] key
to delete the entered value one digit by one digit.
2)
Press [SET] key.
 
27
 
27-1
Purpose
Setting
Function (Purpose) Used to set non-detection of communica-
tion error (U7-00) with RIC. (FSS function)
Section
Operation/Procedure
1)
Enter the set value with 10-key.
2)
Press [OK] key.
The set value in step 1) is saved.
 
27-2
Purpose
Setting
Function (Purpose) Used to set the sender's registration num-
ber and the HOST server telephone num-
ber. (FSS function)
Section
Operation/Procedure
1)
Select an item to be set with touch panel. 
[USER FAX NO] [SERVA TEL NO]
2)
Enter the set value with 10-key.
3)
Press [SET] key.
The set value in step 2) is saved.
 
27-4
Purpose
Setting
Function (Purpose) Used to set the initial call and toner order
auto send. (FSS function)
Section
Operation/Procedure
1)
Select an item to be set with [
] [] keys.
2)
Enter the set value with 10-key.
3)
Press [OK] key.
The set value in step 2) is saved.
Item/Display
Content
Setting 
range
Default 
value
A
OSA TRIAL 
MODE 
(0: YES 1: NO)
0
Used to set the OSA 
trial mode.
0 - 1
1
1
OSA trial mode is 
canceled.
0
Not detection
1
Detection
USER FAX_NO.
Sender registration number (Max. 16 digits)
SERVA TEL_NO.
Host server telephone number (Max. 16 digits)
• If the connection process is not completed 
normally when registering the FSS, calling to the 
HOST may be continuously made every time when 
the power is turned ON (from OFF) or rebooted.
In this case, enter "********" to inhibit calling to the 
HOST.
Item/Display
Content
Setting range
Default value
Remarks
A
FSS MODE
NEB1
Set the FSS MODE
Exclusive for send 
in NE-B mode
0 - 3
0
1
NEB2
Send/Receive in 
NE-B mode
1
NFB1
Exclusive for send 
in NE-F mode
2
NFB2
Send/Receive in 
NE-F mode
3
B
RETRY_BUSY
Resend number setting when busy
0 - 15
2
* 0: No retry
C
TIMER (MINUTE) _BUSY
Resend timer setting (minute) when busy
1 - 15
3
D
RETRY_ERROR
Resend number setting when error
0 - 15
1
* 0: No retry
E
TIMER (MINUTE) _ERROR
Resend timer setting (minute) when error
1 - 15
1
MX-M753N  SIMULATION  6 – 27
 
27-5
Purpose
Setting
Function (Purpose) Used to set the machine tag No. 
(FSS function)
Section
Communication (RIC/MODEM)
Operation/Procedure
1)
Enter the password (max. 8 digits) with 10-key.
The entered password is displayed on the column of "NEW”.
In order to correct the entered password, press the [clear] key
to delete the entered value one digit by one digit.
2)
Press [SET] key.
 
27-6
Purpose
Setting
Function (Purpose) Used to set of the manual service call.
(FSS function)
Section
Operation/Procedure
1)
Enter the set value with 10-key.
2)
Press [OK] key.
The set value in step 1) is saved.
 
27-7
Purpose
Setting
Function (Purpose) Used to set of the enable, alert call out.
(FSS function)
Section
Operation/Procedure
1)
Select an item to be set with [
] [] keys.
2)
Enter the set value with 10-key.
3)
Press [OK] key.
The set value in step 2) is saved.
*1 The FSS function setting can be changed only from Disable to
Enable. (Cannot be changed from Enable to Disable.)
*2 Alert send timing
 
27-9
Purpose
Setting
Function (Purpose) Used to set the paper transport time record-
ing YES/NO threshold value and shading
gain adjustment retry number. 
(FSS function)
Section
Operation/Procedure
1)
Select an item to be set with [
] [] keys.
2)
Enter the set value with 10-key.
3)
Press [OK] key.
The set value in step 2) is saved.
* Items A, B: 0%, standard passing time between sheets of paper;
100%, time for judgment as a jam between sheets of paper.
* Item C: Because of a trouble in shading operation, the number of
retry is actually not registered.
 
27-10
Purpose
Data clear
Function (Purpose) Used to clear the trouble prediction history
information. (FSS function)
Section
Operation/Procedure
1)
Press [EXECUTE] key.
2)
Press [YES] key.
The history information of trouble prediction is cleared.
F
TONER ORDER 
TIMING (K)
100% - 75%
Toner order auto send 
timing setting (K)
100% - 75%
0 - 5
5
3 (49%-25%)
74% - 50%
74% - 50%
4
49% - 25%
49% - 25%
3
LOWER 25
25% or less
2
NEAREND
NEAREND
1
EMPTY
EMPTY
0
Item/Display
Content
Setting range
Default value
Remarks
0
Allow (Default) 
1
Inhibit
A
FSS 
FUNCTION
0
FSS function enable
1
FSS function disable (*1) (Default)
B
ALERT
0
Alert call enable (*2) (Default)
1
Alert call disable
C
CONNECTION
0
FAX connection enable
1
E-MAIL connection enable
No alert cause
Initial state / Trouble / Continuous JAM alert
Maintenance
When the maintenance timing is reached.
Service call
When pressing Service call.
Toner send request
When the toner order automatic send setting is 
reached.
Toner collection request
Revision of the toner installation date (only for 
a new product)
Alert resend
A
FEED TIME 1
0 - 100
Threshold value of the paper 
transport time between sensors 
(Main unit) (50: Default)
B
FEED TIME 2
0 - 100
Threshold value of the paper 
transport time between sensors 
(DSPF) (50: Default)
C
GAIN ADJUSTMENT 
RETRY
0 - 20
Threshold value of the gain 
adjustment retry number 
(11: Default)
D
JAM ALERT
1 - 100
Alert judgment threshold value for 
occurrence of continuous jams
Alert judgment threshold value for 
occurrence of continuous jams 
(Setting of the number of times of 
continuous jams as the alert for 
continuous jams) (Default: 10 
times)
Target history
Serial communication retry number history
High density process control error history
Half tone process control error history
Scanner gain adjustment retry history
DSPF gain adjustment retry history
Paper transport time between sensors
MX-M753N  SIMULATION  6 – 28
 
27-11
Purpose
Other
Function (Purpose) Used to check the serial communication
retry number and the scanner gain adjust-
ment retry number history. (FSS function)
Section
Operation/Procedure
The serial communication retry number history and the scanner
gain adjustment retry number history are displayed.
 
27-12
Purpose
Other
Function (Purpose) Used to check the high-density and the
half-tone process control error history. (FSS
Function)
Section
Operation/Procedure
The high density and the half-tone process control error history are
displayed.
 
27-13
Purpose
Other
Function (Purpose) Used to check the history of paper transport
time between sensors. (FSS function)
Section
Operation/Procedure
Change the display with [
] [] key.
Display Item
Content
Item name
Occurrence date 
(Display)
Retry 
number
LSU1
99/99/99 99:99:99
 8 digits
Serial 
communication retry 
number history 
display
LSU2
99/99/99 99:99:99
8 digits
INSERTER1
99/99/99 99:99:99
8 digits
INSERTER2
99/99/99 99:99:99
8 digits
FINISHER1
99/99/99 99:99:99
8 digits
FINISHER2
99/99/99 99:99:99
8 digits
SCAN GAIN ADJ1
99/99/99 99:99:99
8 digits
Scanner gain 
adjustment retry 
history
SCAN GAIN ADJ2
99/99/99 99:99:99
8 digits
SCAN GAIN ADJ3
99/99/99 99:99:99
8 digits
SCAN GAIN ADJ4
99/99/99 99:99:99
8 digits
SCAN GAIN ADJ5
99/99/99 99:99:99
8 digits
DSPF GAIN ADJ1
99/99/99 99:99:99
8 digits
DSPF gain 
adjustment retry 
history
DSPF GAIN ADJ1
99/99/99 99:99:99
8 digits
DSPF GAIN ADJ2
99/99/99 99:99:99
8 digits
DSPF GAIN ADJ3
99/99/99 99:99:99
8 digits
DSPF GAIN ADJ4
99/99/99 99:99:99
8 digits
DSPF GAIN ADJ5
99/99/99 99:99:99
8 digits
HV_ERR1
High density error history 1
HV_ERR2
High density error history 2
HV_ERR3
High density error history 3
HV_ERR4
High density error history 4
HV_ERR5
High density error history 5
H_TONE ERR1
Half tone error history 1
H_TONE ERR2
Half tone error history 2
H_TONE ERR3
Half tone error history 3
H_TONE ERR4
Half tone error history 4
H_TONE ERR5
Half tone error history 5
Item/Display
Content
Occurrence date
Code 
between 
sensors
Passing time
Reference 
passing 
time
Main 
unit
FEED TIME1
History of paper transport time between sensors 1
99/99/99 99:99:99
5 digits
5 digits (ms)
5 digits (ms)
FEED TIME2
History of paper transport time between sensors 2
99/99/99 99:99:99
5 digits
5 digits (ms)
5 digits (ms)
FEED TIME3
History of paper transport time between sensors 3
99/99/99 99:99:99
5 digits
5 digits (ms)
5 digits (ms)
FEED TIME4
History of paper transport time between sensors 4
99/99/99 99:99:99
5 digits
5 digits (ms)
5 digits (ms)
FEED TIME5
History of paper transport time between sensors 5
99/99/99 99:99:99
5 digits
5 digits (ms)
5 digits (ms)
FEED TIME6
History of paper transport time between sensors 6
99/99/99 99:99:99
5 digits
5 digits (ms)
5 digits (ms)
FEED TIME7
History of paper transport time between sensors 7
99/99/99 99:99:99
5 digits
5 digits (ms)
5 digits (ms)
FEED TIME8
History of paper transport time between sensors 8
99/99/99 99:99:99
5 digits
5 digits (ms)
5 digits (ms)
FEED TIME9
History of paper transport time between sensors 9
99/99/99 99:99:99
5 digits
5 digits (ms)
5 digits (ms)
FEED TIME10
History of paper transport time between sensors 10
99/99/99 99:99:99
5 digits
5 digits (ms)
5 digits (ms)
DSPF
FEED TIME1(SPF)
History of paper transport time between SPF sensors 1
99/99/99 99:99:99
5 digits
5 digits (ms)
5 digits (ms)
FEED TIME2(SPF)
History of paper transport time between SPF sensors 2
99/99/99 99:99:99
5 digits
5 digits (ms)
5 digits (ms)
FEED TIME3(SPF)
History of paper transport time between SPF sensors 3
99/99/99 99:99:99
5 digits
5 digits (ms)
5 digits (ms)
FEED TIME4(SPF)
History of paper transport time between SPF sensors 4
99/99/99 99:99:99
5 digits
5 digits (ms)
5 digits (ms)
FEED TIME5(SPF)
History of paper transport time between SPF sensors 5
99/99/99 99:99:99
5 digits
5 digits (ms)
5 digits (ms)
FEED TIME6(SPF)
History of paper transport time between SPF sensors 6
99/99/99 99:99:99
5 digits
5 digits (ms)
5 digits (ms)
FEED TIME7(SPF)
History of paper transport time between SPF sensors 7
99/99/99 99:99:99
5 digits
5 digits (ms)
5 digits (ms)
FEED TIME8(SPF)
History of paper transport time between SPF sensors 8
99/99/99 99:99:99
5 digits
5 digits (ms)
5 digits (ms)
FEED TIME9(SPF)
History of paper transport time between SPF sensors 9
99/99/99 99:99:99
5 digits
5 digits (ms)
5 digits (ms)
FEED TIME10(SPF)
History of paper transport time between SPF sensors 10
99/99/99 99:99:99
5 digits
5 digits (ms)
5 digits (ms)
Page of 127
Display

Click on the first or last page to see other MX-M623U / MX-M753U (serv.man10) service manuals if exist.