DOWNLOAD Sharp MX-M363N / MX-M363U / MX-M503N / MX-M503U (serv.man18) Service Manual ↓ Size: 19.34 MB | Pages: 117 in PDF or view online for FREE

Model
MX-M363N MX-M363U MX-M503N MX-M503U (serv.man18)
Pages
117
Size
19.34 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / June 10
File
mx-m363n-mx-m363u-mx-m503n-mx-m503u-sm18.pdf
Date

Sharp MX-M363N / MX-M363U / MX-M503N / MX-M503U (serv.man18) Service Manual ▷ View online

MX-M503N  MX-FNX9  4 – 5
E. Staple position label attachment
1)
Attach the label to the position indicated in the figure.
[For scanner] (package part No. 11)
[For DSPF/RSPF] (package part No. 12)
F. Turn on the power of the main unit
1)
Insert the power plug of the main unit into the power outlet.
2)
Open the front cabinet.
Turn ON the power switch in the front cabinet of the main unit. 
3)
Turn ON the power switch on the operation panel.
Second label
Corner R end fitting
Label attachment
reference
Corner of the "upper
cabinet rear"
Corner R end fitting
1mm
1mm
1mm
1mm
DSPF
RSPF
ON
MX-M503N  MX-PNX1  5 – 1
MX-M503N
Service Manual
 
[5] MX-PNX1
1.  Unpacking
A. Removal of the punch unit
B. Removal of the fixing tape
1)
Remove the fixing tape.
C. Check the packed items
1)
Check that all the items are included in the package.
* Do not use the punch position label which is one of the packed
parts, but use one packed in the package of the finisher (MX-
FNX9).
2.  Installation
When the punch unit is installed together with installation of
the MX-FNX9 (inner finisher), first install the inner finisher,
and then install the punch unit.
<Note before installation>
* Before starting installation, check to insure that the data lamp on
the operation panel does not light up or blink.
* Do not install the punch unit first because doing so would cause
interference between the inner finisher slide rail and the punch
unit drawer connector (possibly resulting in failure) when you
attempt to install the inner finisher.
A. Turn off the power of the main unit
1)
Turn OFF the power switch on the operation panel.
2)
Open the front cabinet.
Turn OFF the power switch in the front cabinet of the main unit. 
3)
Disconnect the power plug of the main unit from the power out-
let.
No.
Packed part names
Quantity
1
Punch position label (For scanner)
1
2
Punch position label (For RSPF/DSPF)
1
1
2
OFF
MX-M503N  MX-PNX1  5 – 2
B. Installation of the punch unit
1)
Open the front cabinet.
2)
Open the front cover and slide the inner finisher to the left.
3)
Remove the coin screw, and remove the finisher slide stopper.
4)
Slide the inner finisher further more.
5)
Remove two screws, and remove the front cabinet upper.
6)
Remove the screw, and remove the band and the punch cover.
7)
Remove the screw, and remove the dummy punch unit.
8)
Fix the punch unit with a screw.
* When installing the punch unit, be careful not to bump it
against the drawer connector.
* Fit the positioning pin and insert it.
2
1
1
2
3
MX-M503N  MX-PNX1  5 – 3
9)
Make positioning with the dove (A) and fix the punch unit with
the screw which was fixing the dummy punch unit.
10) Cut the lid of the punch cover with nippers.
11) Remove the dust box.
12) Fix the punch cover and the band together with one screw.
13) Insert the dust box.
14) Install the front cabinet upper part using the two screws
removed in step 5).
15) Insert the finisher slide stopper between the slide rail and the
accuride, and fix it with the coin screw.
16) Slide the inner finisher to the original position, and close the
front cover.
A
A
1
2
2
1
Page of 117
Display