MX-M503N  MX-M283N/M363N/M363U/M453N/M453U/M503N/M503U/M282N/M362N/M452N/M502N  1 – 8
2)
Adjust the guide plates A and B by squeezing their lock levers
and sliding them to match the vertical and horizontal dimen-
sions of the paper to be loaded.
The guide plates A and B are slidable. Slide each guide plate
while squeezing its lock lever.
H. Specifications setup
Used to set the specifications with SIM26 according to the cus-
tomer's request.
To customize the following items after completion of the destination
setup, change the set values.
I. Image quality check
(1) Copy density and gradation check
(Note)
Before checking the copy density and gradation, be sure to execute
the following jobs.
* Execute the high density image correction (Process correction)
forcibly. (SIM 44-6)
* Execute the half-tone image correction forcibly. (SIM 44-26)
(Method)
Make a copy of the gray test chart (UKOG-0162FCZZ), and check
that it is proper.
Note for checking the copy mode density
To check the density, use the gray test chart (UKOG-0162FCZZ).
Set the copy density level to "Manual 3" in the Text/Printed Photo
mode (Manual).
In addition, all the picture quality adjustment settings in the user
adjustment mode must be set to the default (center).
[Check with the gray test chart (UKOG-0162FCZZ)]
In the copy density check with the gray test chart, check to insure
the following conditions.
[Check with the servicing color test chart (UKOG-0317FCZZ/
UKOG-0317FC11 or UKOG-0326FCZZ/UKOG-0326FC11)]
Check to confirm that it is in the conditions shown below.
(2) Printer density and gradation check
If no printer option is installed to the U model, the following proce-
dures are not required. (SIM64-5 does not operate.)
(Note)
Before checking the printer density and gradation, be sure to exe-
cute the following jobs.
* Execute the high density image correction (Process correction)
forcibly. (SIM 44-6)
* Execute the half-tone image correction forcibly. (SIM 44-26)
(Method 1)
Execute SIM 64-5 to print the print test pattern.
Set each set value to the default and press [EXECUTE] key. The
print test pattern is printed.
The print density must be changed gradually from the lighter level
to the darker level. The density changing direction must not be
reversed.
(Method 2)
Execute SIM 67-25 to print the adjustment check pattern.
The print density must be changed gradually from the lighter level
to the darker level. The density changing direction must not be
reversed.
Patch A or B is slightly copied.
SIM No
Content
26
6
Used to set the destination.
SIM No
Content
26
2
LCC paper size setting
3
Used to set the auditor specification mode.
5
Used to set the count mode of the total counter and the 
maintenance counter.
18
Used to set YES/NO of the toner save mode 
(Only in UK and Japan versions)
* For other destination versions, this setup is made by 
the user program.
52
Used to set YES/NO of counting when non-print paper 
is passed through each counter.
53
Used to set YES/NO of user calibration permission.
65
Used to set the limit number of sheets for stapling.
B
A
1
2
3
4
5
6
7
8
9
10
W
SHARP GRAY CHART
SHARP gray chart
Patch 1 is not copied.
Patch 2 is
slightly copied.
Patch 3 is copied.
Serviceman chart (Color patch section)
Patch 7 is slightly
copied or not copied.
Q (Max)
A B C D E F G H I J K L M N O P
Patch A or B is slightly copied.
PRINTER CALIBRATION
High density
Low density
The patch density is identical between patches or not reversed.
The patch density is changed gradually.
MX-M503N  MX-M283N/M363N/M363U/M453N/M453U/M503N/M503U/M282N/M362N/M452N/M502N  1 – 9
J. Function and operation check
Check that the following operations are normal.
K. Setup and adjustment data recording
Print the various setup data and the adjustment data (list) with
SIM22-6 and keep the data.
• In case of a memory trouble, if the data are not kept, all the
adjustments must be made again.
• If the data are kept, the setup values and the adjustment values
can be entered without adjustments, shortening the servicing
time.
L. Necessary works before moving the machine
1)
If the following options are installed, remove all of them from
the machine.
• Finisher
• Large capacity tray
2)
Remove the following consumable parts from the machine.
• Paper
• Toner cartridges
• Development cartridge
3)
Lock the following sections.
• Scanner (Optical section)
• Paper cassette lift plate
NOTE: Since the hard disk drive is built in the machine, use care
not to exert vibrations or shocks to the machine when in
transit.
M. Remote operation panel function Enable 
setting
(1) General
To use the remote operation panel function, the password for the
remote operation panel function must be entered on the password
input menu displayed on the VNC boot screen. Note that, therefore,
the password must be set in advance to use the remote operation
panel function.
Let the user make the password, and use SIM26-78 to set it.
(2) Remote operation panel function password setting 
procedures
1)
Enter the SIM26-78 mode.
2)
Enter the password with 10-key. (Within 5 - 8 digits)
The entered password is displayed on the column of "NEW."
To modify the entered password, use clear key to delete the
password digit by digit.
3)
Press [SET] key, and the password is set.
N. USB PORT selection
There are two USB ports; one on the front frame side and the other
on the rear frame side. Only one of them can be used at a time. Do
not connect the two USB ports simultaneously.
When shipping, the port on the front frame side is valid and the port
on the rear frame side is invalid. When using the USB port, be care-
ful of the total current consumption not to exceed 500mA.
The valid port can be switched by changing the setting of the MFP
PWB DIP SW.
Select the valid USB port according to the user’s request.
* The default setting for SW1/SW2 is OFF.
NOTE: For the machine which is provided with a keyboard, either
one of two USB ports can be used at a time. However, both
DIP SW1’s must be set to OFF.
Note that, if DIP SW1 is set to ON, the machine is set to the
CN update mode.
NOTE: After completion of option installation, revise all the firm-
ware to the latest version.
Check item list
Equipped condition
Key-in (operation panel)
Display (operation panel)
Paper feed 
operation
Hand feed
Main unit paper 
tray
Desk unit paper 
feed tray
With the desk unit installed
Paper size detection
Originals size 
detection
Original table 
mode
DSPF mode
RSPF mode
DSPF/RSPF 
operation / two 
sided copy
S-S mode
D-S mode
S-D mode
D-D mode
Bookbinding operation
When the finisher is installed
Stapling operation
When the finisher is installed
Grouping operation
When the finisher is installed
Sorting operation
When the finisher is installed
Paper exit operation
When the exit tray unit (MX-TRX2) 
is installed
MFP PWB DIP SW
USB I/F
SW 1
SW 2
Port on the front 
frame side
Port on the rear 
frame side
OFF
OFF
Valid
Invalid
OFF
ON
Invalid
Valid
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
523(3$66:25'6(77,1*
35(6(17˖
ǂǂ1(:˖
6(7
Upper side: DIP-SW1
Lower side: DIP-SW2
When tilted toward you: OFF
When tilted to the PWB side: ON
MX-M503N  MX-DEX8/DEX9  2 – 1
MX-M503N
Service Manual
 
[2] MX-DEX8/DEX9
1.  Unpacking
A. Removal of the desk unit
B. Removal of the fixing material and packing 
parts
* If the connector is removed first, it may be pinched in the install-
ing procedures. Therefore, keep it packed when unpacking the
package, and unpack it when connecting the connector to the
machine.
1)
Remove the fixing material and packing parts.
C. Check the packed items
1)
Check that all the items are included in the package.
2.  Installation
<Note before installation>
* Before starting installation, check to insure that the data lamp on
the operation panel does not light up or blink.
A. Turn off the power of the main unit
1)
Turn OFF the power switch on the operation panel.
2)
Open the front cabinet. 
Turn OFF the power switch in the front cabinet of the main unit.
3)
Disconnect the power plug of the main unit from the power out-
let.
No.
Names of bundles
Quantity
1
Right adjuster
1
2
Fixing screws (M4 x 8)
4
1
2
OFF
MX-M503N  MX-DEX8/DEX9  2 – 2
B. Installation of the adjuster
1)
Install the right adjuster (package part No. 1) to the desk unit.
2)
Turn each adjuster to fix the desk unit.
C. Connection of the main unit and the desk unit
1)
Remove the connection plate covers of the both sides of the
main unit.
2)
Put the main unit on the desk unit.
* Use man power of four persons or more to lift the main unit.
* Place the main unit on the desk unit slowly by fitting the
external lines. Check to insure that the positioning pin on the
top of the desk unit is securely engaged in the positioning
groove of the main unit.
3)
Remove the No. 2 paper feed tray.
4)
Pull out the No. 3 paper feed tray until it stops.
1
2
2
1
1
2
Page of 117
Display

Click on the first or last page to see other MX-M363N / MX-M363U / MX-M503N / MX-M503U (serv.man18) service manuals if exist.