Sharp MX-M200D / MX-M200DK (serv.man2) Service Manual ▷ View online

MX-M200D ADJUSTMENT 6-9
b. SPF original off-center adjustment (SIM50-12)
Note:Before performing this adjustment, be sure to check that the paper 
off center is properly adjusted. 
1) Make a test chart for the center position adjustment and set it on the 
SPF. 
<Adjustment specification>
Draw a line on a paper in the scanning direction. 
2) Make a normal copy from the bypass tray, and compare the copy and 
the original test chart.
 
If necessary, perform the following adjustment procedures. 
3) Execute SIM 50-12. 
4) After warm-up, shading is performed and the current set value of the 
off center adjustment at each paper feed port is displayed on the 
display section in 2 digits. 
5) Enter the set value and press the [START] key. 
 
The set value is stored and a copy is made. 
<Adjustment specification>
(8) SPF white correction pixel position adjustment(SIM63-7)
 
(required in an SPF model when replacing the lens unit)
1) Fully open the SPF.
2) Execute SIM 63-7.
 
If the value is 93 - 229, it is displayed on the display and written into 
the EEPROM. 
 
If the value is 0 - 92 or 230 - 999, it is displayed on the display but not 
written into the EEPROM.
 
If the value is 1000 or above, “--” is displayed on the display and it is 
not written into the EEPROM.
•When the display is 0:
Check that the SPF is open.
Check that the lamp is ON.(If the lamp is OFF,check the MCU 
connector.)
Check that the CCD harness is properly inserted into the MCU 
connector.
•When the display is 281 or above:
1) Remove the table glass.
2) Remove the dark box.
3) Slide the lens unit toward the front side and attach it,then execute 
SIM.
•When the display is 143 or below:
1) Remove the table glass.
2) Remove the dark box.
3) Slide the lens unit toward the rear side and attach it,then execute 
SIM.
*
When the lens unit is moved,execute the OC main scanning 
magnification ratio auto adjustment,SIM 48-1-1,SIM48-3 and the PF 
original off-center adjustment.
*
This adjustment is basically O.K.with SIM 63-7.
C.Image density adjustment
(1)Copy mode (SIM 46-1)
1)Set a test chart (UKOG-0162FCZZ) on the OC table as shown below.
2) Put several sheets of A3 or 11" x 17" white paper on the test chart. 
3) Execute SIM 46-1.
4) After warm-up, shading is performed and the current set value of the 
density level is displayed on the display section in 2 digits. 
 
For mode selection, use the AUTO/TEXT/PHOTO key. 
5) Change the set value with the numeric keys to adjust the copy image 
density.
6) Make a copy and check that the specification below is satisfied.
 
<Adjustment specification>
Mode
Specification
SIM
Set value
Set
range
Original off 
center 
mode
(SPF mode)
Single:
Center ±3.0mm(TEXT 
indicator)
SIM
50-12
Add 1:
 
0.1mm shift 
to R side
Reduce 1: 
0.1mm shift 
to L side
1 ~ 99
Duplex:
Center ±3.5mm(PHOTO 
indicator)
R
F
Density 
mode
LED
Exposure 
level
Sharp Gray 
Chart output
Set value
Set 
range
Auto
Auto
-
"2" is slightly 
copied.
The greater the 
set value is the 
greater the 
density is The 
smaller the set 
value is the 
smaller the 
density is.
1 ~ 99
Text
Text
3
"3" is slightly 
copied.
Photo
(Error 
diffusion)
Photo
3
"2" is slightly 
copied.
Toner 
save
Auto/
Photo
-
"2" is slightly 
copied
Toner 
save
Text/
Photo
3
"3" is slightly 
copied
Photo
(Dither)
Auto/
Text/
Photo
3
"2" is slightly 
copied
MX-M200D SIMULATIONS 7-1
[7] SIMULATIONS
1. Entering the simulation mode
Perform the following procedure to enter the simulation mode.
[#] key 
  [
] key 
 [C] key 
  [
] key 
 
Main code 
 [START] key 
 Sub code 
 [START] key
2. Canceling the simulation mode
When the clear all key is pressed, the simulation mode is cancelled.
When the interruption key is pressed, the process is interrupted and the 
screen returns to the sub code entering display.
* After canceling the simulation mode, be sure to turn OFF/ON the 
power and check the operation.
Note: If the machine is terminated by a jam error or paper empty during 
copying in the adjustment by the simulation, recopying is required.
Note:The values in the simulation columns are not default values but 
sample values.
3. List of simulations
Main 
code
Sub 
code
Contents
01
01
Mirror scanning operation
02
Mirror home position sensor (MHPS) status display
02
01
Single paper feeder (SPF)/Reversing single pass 
feeder(RSPF) aging *2
02
SPF/RSPF sensor status display *2
03
SPF/RSPF motor operation check *2
08
SPF/RSPF paper feed solenoid operation check  *2
09
RSPF reverse solenoid operation check *2 *3
11
SPF/RSPF PS release solenoid operation check *2
03
02
Shifter/job separator sensor status display
03
Shifter operation check
04
Job separator operation check *4
11
Shifter home position check
05
01
Operation panel display check 
02
Fusing lamp and cooling fan operation check 
03
Copy lamp lighting check 
06
01
Paper feed/transport solenoid operation check
02
Resist roller solenoid (RRS) operation check
10
Main cassette pickup roller cleaning
07
01
Warm-up display and aging with jam detection
06
Intermittent aging
08
Shifting with warm-up display 
08
01
Developing bias output
02
Main charger output (Grid = HIGH)
03
Main charger output (Grid = LOW)
06
Transfer charger output
09
01
Duplex motor forward rotation check *6
02
Duplex motor reverse rotation check  *6
04
Duplex motor RPM adjustment *6
05
Duplex motor switchback time adjustment
10
-
Toner motor operation 
14
-
Trouble cancel (except for U2) 
16
-
U2 trouble cancel
20
01
Maintenance counter clear
21
01
Maintenance cycle setting
22
01
Counters display
03
Jam memory display
04
Jam total counter display
07
Key operator code display
09
Paper feed counter display
13
CRUM destination display *5
14
P-ROM version display
15
Trouble memory display
22
SPF/RSPF jam counter display *2
24
01
Jam total counter clear
02
Trouble memory clear
04
SPF/RSPF counter clear *2
05
Duplex print counter clear *6
06
Paper feed counter clear
07
Drum counter clear
08
Copy counter clear
09
Printer counter clear
13
Scanner counter clear
14
SPF/RSPF jam total counter clear *2
15
Scanner mode counter clear
25
01
Main motor operation check (Cooling fan motor rotation 
check)
MX-M200D SIMULATIONS 7-2
<Execution inhibit conditions>
*1) Execution is inhibited when the duplex setup is OFF and other than 
RSPF is set. 
*2) Execution is inhibited when OC.
*3) Execution is inhibited when SPF. (Not RSPF)
*4) Execution is inhibited when the job separator is not installed.
*5) Execution is inhibited when the model is not provided with the 
CRUM. 
*6) Execution is inhibited when the duplex setup is OFF. 
25
02
Toner density reference control level setting (automatic 
development adjustment)
10
Polygon motor operation check 
26
01
Job separator setting
02
Size setting
03
Auditor setting
04
Copier duplex setting
05
Count mode setting
06
Destination setting
07
Machine condition check
18
Toner save mode setting
20
Job separator paper exit mode setting
22
Language setting clear
30
CE mark conformity control ON/OFF
31
Auditor mode exclusive setup
36
Cancel of stop at maintenance life over
37
Cancel of stop at developer life over
38
Cancel of stop at drum life over
39
Memory capacity check
42
Transfer ON/OFF timing control setting
43
Side void amount setting
51
Copy temporary stop function setting
54
LCD contrast PWM duty setting
56
Life correction ON/OFF setting
60
[FAX] key Enable/Disable setting
73
Toner save setting display/non-display
74
Total counter display change setting
30
01
Paper sensor status display
41
01
Document size detection photo sensor check
02
Document size detection photo sensor detection level 
adjustment
03
Document size detection photo sensor light receiving/
detection level check
04
Detection level adjustment when the document size is 
settled(15degrees - 20degrees)
42
01
Developing counter clear
43
01
Fusing temperature setting (Normal copy)
12
Standby mode fusing fan rotation setting
13
Paper interval control allow/inhibit setting
44
01
Enable/Disable setting of toner density control 
correction
16
Toner density control data check and toner density 
correction quantity display
34
Transfer current setting
46
01
Copy density adjustment (300dpi)
02
Copy density adjustment (600dpi)
09
Copy exposure level adjustment, individual setting 
(Text) 300dpi
10
Copy exposure level adjustment, individual setting 
(Text) 600dpi
11
Copy exposure level adjustment, individual setting 
(Photo) 600dpi
18
Image contrast adjustment (300dpi)
19
Exposure mode setting
(Gamma table setting/AE operation mode setting/
Photo image process setting)
20
SPF/RSPF exposure correction *2
29
Image contrast adjustment (600dpi)
30
AE limit setting
46
31
Image sharpness adjustment
Main 
code
Sub 
code
Contents
48
01
Main/sub scanning magnification ratio adjustment
05
SPF/RSPF mode sub scanning magnification ratio 
adjustment in copying *2
49
01
Flash ROM program writing mode
50
01
Image lead edge adjustment
06
Copy lead edge position adjustment (SPF/RSPF) *2
10
Paper off-center adjustment
12
Document off-center adjustment 
18
Memory reverse position adjustment in duplex copy *1
19
Rear edge void adjustment in duplex copy *6
51
02
Resist amount adjustment
53
08
SPF/RSPF scanning position automatic adjustment *2
10
SPF/RSPF scanning position setting
61
02
Laser power correction ON/OFF
03
HSYNC output check 
63
01
Shading check
07
SPF/RSPF automatic correction *2
64
01
Self print
65
10
Key reception time setting display/non-display setting
11
Info lamp setting
67
50
USB reception speed adjustment
Main 
code
Sub 
code
Contents
MX-M200D SIMULATIONS 7-3
4. Contents of simulations
Main 
code
Sub 
code
Contents
Remark
01
01
Mirror scanning operation
Used to check the operations of the scanner unit and its control circuit. 
Enter the number of times and the magnification ratio, and press [OK] key to operate the scanner unit. The 
speed is variable according to the specified magnification ratio. The number of scanning can be specified by 
entering a value to the right lower section of the LCD.
•Setting range of magnification ratio: 25%-400%
•Setting range of the number of scanning: 0-999 (When 0 is set, it means unlimited. )
Used to display the status (ON/OFF) of the mirror HP sensor on the LCD during scanning. (Highlighted at 
ON)
"EXEC" is displayed to indicate execution is in process. The scan counter is displayed above "EXEC." This 
counter is counted up even in simulation.
 The copy lamp is lighted during scanning.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Returns to the sub code input window.
[C] key: Input value clear
Numeric keys: Input of the number of scanning
02
Mirror home positions sensor (MHPS) status display
Used to monitor the mirror home position sensor and display the ON/OF status of the sensor on the LCD.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Returns to the sub code input window.
Sim1-1 SCAN CHECK
MHPS
[OK] key or [START] Key
MHPS sensor status
Scan counter
(Scan number input window)
(Execution
         window)
Highlighted during execution
ZOOM
100%
5
123
Sim1-1 SCAN CHECK
ZOOM
100%
EXEC
123
MHPS
Set the scan magnification ration.
This magnification ratio accords with the scan speed
in actual copying. The setting range is 25% - 400%. 
Specify the scan number to be performed. 
The setting range is 0 - 999. When 0 is set,
the number is unlimited.
115%
100%
  86%
115%
100%
  86%
Sim1-2 SENSOR CHECK
MHPS
MHPS(MIRROR HOME POSITION SENSOR)
ON
:Highlight display
OFF
:Normal display
Page of 121
Display

Click on the first or last page to see other MX-M200D / MX-M200DK (serv.man2) service manuals if exist.