MX-M200D ADJUSTMENT 6-5
2) Loosen the copy lamp unit wire fixing screw.
3) Manually turn the mirror base drive pulley and bring No. 2/3 mirror 
base unit into contact with the positioning plate. At that time, if the 
front frame side and the rear frame side of No. 2/3 mirror base unit 
are brought into contact with the positioning plate at the same time, 
the mirror base unit parallelism is proper. If one of them is in contact 
with the positioning plate, perform the adjustment of 4).
4) Loosen the set screw of the scanner drive pulley which is not in 
contact with No. 2/3 mirror base unit positioning plate.
5) Without moving the scanner drive pulley shaft, manually turn the 
scanner drive pulley until the positioning plate is brought into contact 
with No. 2/3 mirror base unit, then fix the scanner drive pulley.
6) Put No. 2/3 mirror base unit on the positioning plate again, push the 
projections on the front frame side and the rear frame side of the 
copy lamp unit to the corner frame, and tighten the wire fixing screw.
Wire fixing screw
MX-M200D ADJUSTMENT 6-6
(3)Main scanning direction (FR direction) distortion 
adjustment
This adjustment must be performed in the following cases:
•When the mirror base drive wire is replaced.
•When the lamp unit, or No. 2/3 mirror holder is replaced.
•When a copy as shown is made.
1) Set A3 (11" x 17") white paper on the original table as shown below.
2) Open the original cover and make a normal (100%) copy. 
3) Measure the width of the black background at the lead edge and at 
the rear edge. 
If the width (La) of the black background at the lead edge is equal that 
(Lb) at the rear edge, there is no need to execute the following 
procedures of 4) ~ 7).
4) Loosen the mirror base drive pulley fixing screw on the front frame 
side or on the rear frame side. 
5)Tighten the mirror base drive pulley fixing screw. 
<Adjustment specification>
La = Lb
6) Execute the main scanning direction (FR) distartion balance 
adjustment previously described in 2) again.
(4) Sub scanning direction (scanning direction) distortion 
adjustment
When there is no skew copy in the mirror base scanning direction and 
there is no horizontal error (right angle to the scanning direction), the 
adjustment can be made by adjusting the No. 2/3 mirror base unit rail 
height.
Before performing this adjustment, be sure to perform the horizontal 
image distortion adjustment in the laser scanner section. 
This adjustment must be performed in the following cases:
•When the mirror base wire is replaced.
•When the copy lamp unit or No. 2/3 mirror unit is replaced. 
•When the mirror unit rail is replaced or moved.
•When a following copy is made.
Lb
La
Original
Copy
Paper exit 
direction
Fit the paper edge and
 the glass holding plate edge. 
 A3 
(11" 
x 17") white paper
Glass holding plate
Allow a little space. 
Paper exit direction
La: Lead edge black background width
Lb: Rear edge black background width
A
B
Rear side
Front side
When La < Lb
Turn the mirror base drive pulley on the front frame side in the
arrow direction A.
(Do not move the mirror base drive pulley shaft.)
When La > Lb
Turn the mirror base drive pulley on the front frame side in the
arrow direction A.
(Do not move the mirror base drive pulley shaft.)
Original
Copy A
Copy B
MX-M200D ADJUSTMENT 6-7
1) Making of a test sheet 
 
Make test sheet by drawing parallel lines at 10mm from the both 
ends of A3 (11" x 17") white paper as shown below. (These lines 
must be correctly parallel to each other.)
2) Make a normal (100%) copy of the test sheet on A3 (11" x 17") 
paper. (Fit the paper edge with the glass holding plate edge.)
3) Measure the distances (La, Lb, Lc, Ld) at the four corners as shown 
below. 
When La = Lb and Lc = Ld, no need to perform the procedures 4) and 5).
4) Move the mirror base F rail position up and down (in the arrow 
direction) to adjust. 
Note:Do not adjust the rail on the rear side. 
If the rail on the rear side is adjusted, an error may occur. 
Only the rail on the front side can be adjusted.
<Adjustment specification>
La = Lb, Lc = Ld
5) After completion of adjustment, manually turn the mirror base drive 
pulley, scan the mirror base A and mirror base B fully, and check that 
the mirror bases are not in contact with each other. 
*
If the mirror base rail is adjusted to extreme, the mirror base may 
contact the frame or original glass. Be careful to avoid this.
(5) Main scanning direction (FR direction) magnification 
ratio adjustment (SIM 48-1)
Note: Before performing this adjustment, be sure the CCD unit is within 
specification.
1) Put a scale on the original table as shown below.
2) Execute SIM 48-1.
3) After warm-up, shading is performed and the current set value of the 
main scanning direction magnification ratio is displayed on the 
display section in 2 digits. 
4) Select the mode and press the [START] key again. 
5) Manual correction mode (TEXT indicator ON)
 
Enter the set value and press the [START] key. 
 
The set value is stored and a copy is made.
 
10mm
10mm
10mm
10mm
Parallel line
White paper
Parallel line
La
Lb
Ld
Lc
Paper exit 
direction 
When La > Lb
Shift the mirror base B rail upward by the half of the
difference of La - Lb.
When La < Lb
Shift the mirror base B rail downward by the half of the
difference of Lb - La.
Example: When La = 12mm and Lb = 9mm, shift the mirror
base B rail upward by 1.5mm.
When Lc > Ld
Shift the mirror base B rail downward by the half of the
difference of Lc - Ld.
When Lc < Ld
Shift the mirror base B rail downward by the half of the
difference of Ld - Lc.
When moving the mirror base rail, hold the mirror base rail
with your hand.
MX-M200D ADJUSTMENT 6-8
<Adjustment specification>
Note: A judgment must be made with 200mm width, and must not be 
made with 100mm width.
(6) Sub scanning direction (scanning direction) 
magnification ratio adjustment (SIM 48-1, SIM 48-5)
a. OC mode in copying (SIM48-1)
Note:Before performing this adjustment, be sure the CCD unit is within 
specification. 
1) Put a scale on the original table as shown below, and make a normal 
(100%) copy. 
2) Compare the scale image and the actual image. If necessary, 
perform the following adjustment procedures. 
3) Execute SIM 48-1.<<PHOTO>>
4) After warm-up, shading is performed and the current set value of the 
main scanning direction magnification ratio is displayed on the 
display section in 2 digits.
5) When the photo  indicator is lighted by pressing the AUTO/TEXT/
PHOTO key, the current magnification ratio correction value in the 
sub scanning direction is displayed in lower 2 digits of the display 
section. 
6) Enter the set value and press the [START] key.
 
The set value is stored and a copy is made.
<Adjustment specification>
b. RSPF sub scanning direction magnification ratio (SIM48-5)
Note:
•Before performing this adjustment, be sure the CCD unit is within 
specification.
•Before performing this adjustment, the OC mode adjustment in copying 
must be completed.
1) Put a scale on the original table as shown below, and make a normal 
(100%) copy to make a test chart.
Note: Since the printed copy is used as a test chart, put the scale in 
parallel with the edge lines.
2) Set the test chart on the SPF and make a normal (100%) copy. 
3) Compare the scale image and the actual image. If necessary, 
perform the following adjustment procedures. 
4) Execute SIM 48-5. 
5) After warm-up, shading is performed.
 
The AUTO indicator lights up and the current front surface sub 
scanning direction magnification ratio correction value is displayed in 
two digits on the display section.
6) Enter the set value and press the [START] key.
 
The set value is stored and a copy is made. 
7) Change the mode from the duplex original mode to the simplex 
original mode.
 
TEXT indicator lights up and the current back surface sub scanning 
direction magnification ratio is displayed in two digits on the display 
section.
8) Enter the set value and press the  [START] key.
 
The set value is stored and a copy is made. 
<Adjustment specification>
(7) Off center adjustment (SIM 50-12)
a. OC mode (SIM50-12)
1) Make a test chart as shown below and set it so that its center line is 
fit with the original guide center mark.
*
To make a test chart, draw a line on A3 or 11" x 17" paper at the 
center in the paper transport direction.
2) Make a normal copy from the bypass tray, and compare the copy and 
the test chart.
 
If necessary, perform the following adjustment procedures. 
3) Execute SIM 50-12. 
4) After warm-up, shading is performed and the current set value of the 
off center adjustment is displayed on the display section in 2 digits.
5) Enter the set value and press the  [START] key.
 
The set value is stored and a copy is made.
<Adjustment specification>
Mode
Specification
 SIM
 Set value
 Set range
Main scanning 
direction 
magnification 
ratio
At normal: 
±1.0%
SIM 48-1 Add 1:0.1% 
increase
Reduce 1: 
0.1%
 
decrease
 1 ~ 99
Mode
Specification
 SIM
 Set value
 Set range
Sub scanning 
direction 
magnification 
ratio
(OC mode)
Normal
 
±1.0%
SIM 48-1
(PHOTO)
Add 1:0.1% 
increase
Reduce 1: 
0.1% 
decrease
 1 ~ 99
Mode
Specification
SIM
Set value
Set range
Sub scanning 
direction 
magnification 
ratio
 
(SPF mode)
Normal 
 
±1.0%
SIM 48-5  Add 1:0.1% 
increase
Reduce 1: 
0.1% 
decrease
1 ~ 99
Mode
Specification
SIM
Set value
Set range
Original off 
center mode
(OC mode)
Single:
Center ±2.0mm
SIM 50-12
(AUTO 
indicator 
ON)
Add 1:
 
0.1mm shift 
to R side
Reduce 1: 
0.1mm shift 
to L side
1 ~ 99
Center
Original guide
Copy paper 
(A3 or 17" x 11")
Page of 121
Display