Sharp MX-M200D / MX-M200DK (serv.man2) Service Manual ▷ View online

MX-M200D SIMULATIONS 7-4
02
01
Single Paper Feeder(SPF)/Reversing single pass feeder(RSPF)aging
Used to check the operations of the SPF/RSPF unit and its control circuit.
Enter the magnification ratio and press[OK] key or [START] key to drive the SPF/RSPF unit at the speed 
corresponding to the setting.
* When [INTERRUPT] key is press, the simulation is terminated and the machine returns to the sub code 
input window. 
* When [CA] key is pressed, the simulation is terminated and the machine exits the simulation mode. 
02
SPF/RSPF sensor status display
Used to display the sensor status in the SPF/RSPF section. An active sensor is highlighted.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Returns to the sub code input window.
Only when the SPF/
RSPF is installed.
03
SPF/RSPF motor operation check
Used to check the operation of the SPF/RSPF motor and its control circuit. When this simulation is 
executed, the initial menu shown below is displayed. Select the magnification ratio to drive the motor.
[CA] key: The SPF/RSPF motor is stopped, and the machine exits the simulation mode. 
[INTERRUPT] key: The SPF/RSPF motor is stopped, and the machine returns to the sub code input window.
Only when the SPF/
RSPF is installed.
Main 
code
Sub 
code
Contents
Remark
Sim2-1 SPF AGING
115%
100%
  86%
1SIDE
2SIDE
[OK] key or [START] Key
(Magnification ratio selection window)
ZOOM
100%
EXEC
Sim2-1 SPF AGING
115%
100%
  86%
1SIDE
2SIDE
(Execution
         window)
ZOOM
100%
EXEC
Select the scan magnification ratio (drive speed).
This also accords with the magnification ratio and
the speed in copying similarly to the OC.
The setting range is 50% - 200%.
"EXEC" is highlighted during execution.
Sim2-2 SENSOR CHECK
SPFP
OCCV
POUT
SPFC
L1
L2
W0
W1
W2
W3
Displayed name
: Sensor name
SPFP
:SPF document transportation sensor
OCCV
:SPF unit (OC cover) open/close sensor
POUT
:SPF paper exit sensor
SPFC
:SPF paper feed cover open/close sensor
L1
:SPF paper length sensor 1
L2
:SPF paper length sensor 2
W0
:SPF document set sensor
W1
:SPF paper width sensor (small) 
W2
:SPF paper width sensor (middle)
W3
:SPF paper width sensor (large)
Sim2-3 OUTPUT CHECK
Sim2-3 OUTPUT CHECK
115%
100%
  86%
[OK] key or [START] Key
(Initial window = Magnification ratio selection window)
ZOOM
100%
EXEC
115%
100%
  86%
ZOOM
100%
EXEC
(Execution
         window)
Select the scan magnification ratio (drive speed).
This also accords with the magnification ratio and
the speed in copying.
The setting range is 50% - 200%.
"EXEC" is highlighted during execution.
MX-M200D SIMULATIONS 7-5
02
08
SPF/RSPF paper feed solenoid operation check
Used to drive the SPF/RSPF paper feed solenoid (PSOL) 20 times in the cycle of 500msec of "ON" and 
500msec of "OFF." After completion of the process, the machine returns to the sub code input window.
When [INTERRUPT] key is pressed, the machine returns to the sub code input window.
When [CA] key is pressed, the machine exits the simulation mode. 
(Only when the 
SPF/RSPF is 
installed.}
09
RSPF reverse solenoid operation check
Used to drive the RSPF reverse solenoid (RSOL) 20 times in the cycle of 500msec of "ON" and 500msec of 
"OFF." After completion of the process, the machine returns to the sub code input window.
When [INTERRUPT] key is pressed, the machine returns to the sub code input window.
When [CA] key is pressed, the machine exits the simulation mode.
(Only when the 
RSPF is installed.)
11
SPF/RSPF PS release solenoid operation check
Used to drive the SPF/RSPF PS release solenoid (CLH) 20 times in the cycle of 500msec of "ON" and 
500msec of "OFF." After completion of the process, the machine returns to the sub code input window.
When [INTERRUPT] key is pressed, the machine returns to the sub code input window.
When [CA] key is pressed, the machine exits the simulation mode.
(Only when the 
SPF/RSPF is 
installed.)
03
02
Shifter/job separator sensor status display
Used to monitor the sensors related to the shifter and the job separator and display the sensor status on the 
LCD. An active sensor is highlighted.
* Displayed only when the job separator is installed except for SFTH.
(Sensor of shifter is 
Japan only)
(Only when the job 
separator is 
installed.)
Main 
code
Sub 
code
Contents
Remark
Sim2-8  SPUS CHECK
PRESS OK KEY
EXEC
Sim2-8  SPUS CHECK
EXEC
[OK] key or [START] Key
(Initial window)
(Execution window)
Sim2-9  SPFS CHECK
PRESS OK KEY
EXEC
Sim2-9  SPFS CHECK
EXEC
[OK] key or [START] Key
(Initial window)
(Execution window)
Sim2-11  CLH CHECK
PRESS OK KEY
EXEC
Sim2-11  CLH CHECK
EXEC
[OK] key or [START] Key
(Initial window)
(Execution window)
Sim3-2 SENSOR
SFTHP
TRYF
JSUP
TRYD
JSDL
Displayed name
:Sensor name
SFTHP
:Shifter home position sensor
JSUP
:Job separator upper limit sensor
JSDL
:Job separator lower limit sensor
TRYF
:Tray full sensor
TRYD
: Paper exit sensor
MX-M200D SIMULATIONS 7-6
03
03
Shifter operation check
Used to reciprocate the shifter 4 times.
During execution, the status of the shifter HP sensor is displayed on the right upper section of the screen. 
(When the sensor is detected, the display is highlighted.)
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Returns to the sub code input window.
* When the above [CA] key or [INTERRUPT] key is pressed during operation of the shifter, the shifter is 
returned to the home position before terminating the operations.
Japan only
04
Job separator operation check
Used to operate the job separator up and down for 30sec.
During operation, the status of the upper limit sensor and the lower limit sensor is displayed on the right 
upper section of the display.
[CA] key: Exits the simulation mode.
 
[INTERRUPT] key: Returns to the sub code input window.
When the operation is interrupted, the job separator is shifted to the home position before terminating the 
simulation similarly to the shifter.
(Only when the job 
separator is 
installed.)
11
Shifter home position check
Used to check the operations of the shifter HP sensor and the shifter. When this simulation is executed, the 
initial menu is displayed. By the following key operations, the left operation and the right operation of the 
home position sensor and the shifter can be executed separately.
[ ] key: Shifts to R side by the specified steps.
[ ] key: Shifts to F side by the specified steps.
[ ] key: Shift to the home position.
[SFTHP] is highlighted when the HP sensor is detected.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Returns to the sub code input window. 
Japan only
Main 
code
Sub 
code
Contents
Remark
Sim3-3  SHIFTER CHK
PRESS OK KEY
EXEC
Sim3-3  SHIFTER CHK
EXEC
SFTHP
[OK] key or [START] Key
(Initial window)
(Execution window)
Sim3-4  JOBSEPA CHK
PRESS OK KEY
EXEC
Sim3-4  JOBSEPA CHK
EXEC
JSDL
JSUP
[OK] key or [START] Key
(Initial window)
(Execution window)
Display
name
JSUP
Job separator 
upper limit sensor
JSDL
Job separator 
lower limit sensor
Sensor
name
Sim3-11 SHIFTER CHK
SFTHP
(Initial window)
[    ]:R [    ]:HP [    ]:F
MX-M200D SIMULATIONS 7-7
05
01
Operation panel display check
<LED/LCD check mode>
Used to check the operations (ON, display) of the LED and the LCD on the operation panel.
When this simulation is executed, all LED's on the operation panel (including 7SEG) are lighted and 
checking LCD is started.
For the operation check of LCD, the area is divided into two sections; upper section and lower section, and 
the display cycle of Normal 
 Dark 
 Light 
 Off is repeated in each section. Each display period is 
2sec.
When [INTERRUPT] key is pressed in the LED check mode, the machine returns to the sub code input 
window.
When [CA] key is pressed, the machine exits the simulation mode.
When [START] key is pressed during LCD display, the machine goes to the key input check mode.
<Key input check mode>
Used to check that the keys on the operation panel are properly detected.
When the machine enters the key input check mode, the initial menu is displayed.
When any key is pressed, the value on the right lower side is counted up.
If a key is pressed once, it is not counted again.
When [CA] key is pressed for the first time, it is counted. When it is pressed for the second time, the 
simulation mode is terminated.
When [INTERRUPT] key is pressed for the first time, it is counted. When it is pressed for the second time, 
the window returns to the sub code input standby window.
* Note for the key input check mode
 
[START] key must be pressed at the end. If it is pressed midway, the simulation judges that the last key is 
pressed and terminates the check mode. Multi input of tow or more keys is ignored. 
Main 
code
Sub 
code
Contents
Remark
Sim5-1 LCD/LED CHK.
Normal
Sim5-1 LCD/LED CHK.
Dark
Sim5-1 LCD/LED CHK.
Light
Sim5-1 LCD/LED CHK.
Normal
Dark
Sim5-1 LCD/LED CHK.
Light
Sim5-1 LCD/LED CHK.
Sim5-1 LCD/LED CHK.
Off
Sub code input standby window
Sim5-1 LCD/LED CHK.
0
(Initial window)
Page of 121
Display