DOWNLOAD Sharp MX-M182 / MX-M182D (serv.man5) Service Manual ↓ Size: 9.62 MB | Pages: 127 in PDF or view online for FREE

Model
MX-M182 MX-M182D (serv.man5)
Pages
127
Size
9.62 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Service Manual December 2011.
File
mx-m182-mx-m182d-sm5.pdf
Date

Sharp MX-M182 / MX-M182D (serv.man5) Service Manual ▷ View online

MX-M182 SIMULATIONS 7-1
[7] SIMULATIONS
1. Entering the simulation mode
Perform the following procedure to enter the simulation mode.
[#] key 
  [
] key 
 [C] key 
  [
] key 
 
Main code 
 [START] key 
 Sub code 
 [START] key
2. Canceling the simulation mode
When the [CA] key is pressed, the simulation mode is cancelled.
When the interruption key is pressed, the process is interrupted and the 
screen returns to the sub code entering display.
*
After canceling the simulation mode, be sure to turn OFF/ON the 
power and check the operation.
Note: If the machine is terminated by a jam error or paper empty during 
copying in the adjustment by the simulation, recopying is required.
Note: The values in the simulation columns are not default values but 
sample values.
3. List of simulations
Main 
code
Sub 
code
Contents
01
01
Mirror scanning operation
02
Mirror home position sensor (MHPS) status display
02
01
Single paper feeder (SPF)/Reversing single pass 
feeder(RSPF) aging *2
02
SPF/RSPF sensor status display *2
03
SPF/RSPF motor operation check *2
08
SPF/RSPF paper feed solenoid operation check  *2
09
RSPF reverse solenoid operation check *2 *3
11
SPF/RSPF PS release solenoid operation check *2
03
02
Shifter/job separator sensor status display
03
Shifter operation check
04
Job separator operation check *4
11
Shifter home position check
05
01
Operation panel display check 
02
Fusing lamp and cooling fan operation check 
03
Copy lamp lighting check 
06
01
Paper feed/transport solenoid operation check
02
Resist roller solenoid (RRS) operation check
07
01
Warm-up display and aging with jam detection
06
Intermittent aging
08
Shifting with warm-up display 
08
01
Developing bias output
02
Main charger output (Grid = HIGH)
03
Main charger output (Grid = LOW)
06
Transfer charger output
09
01
Duplex motor forward rotation check *6
02
Duplex motor reverse rotation check  *6
04
Duplex motor RPM adjustment *6
05
Duplex motor switchback time adjustment
10
-
Toner motor operation 
14
-
Trouble cancel (except for U2) 
16
-
U2 trouble cancel
20
01
Maintenance counter clear
21
01
Maintenance cycle setting
22
01
Counters display
03
Jam memory display
04
Jam total counter display
07
System setting code display
09
Paper feed counter display
11
FAX-related counter display
13
CRUM destination display *5
14
P-ROM version display
15
Trouble memory display
22
SPF/RSPF jam counter display *2
24
01
Jam total counter clear
02
Trouble memory clear
04
SPF/RSPF counter clear *2
05
Duplex print counter clear *6
06
Paper feed counter clear
07
Drum counter clear
08
Copy counter clear
09
Printer counter clear
10
FAX-related counter clear
13
Scanner counter clear
14
SPF/RSPF jam total counter clear *2
15
Scanner mode counter clear
25
01
Main motor operation check (Cooling fan motor rotation 
check)
02
Auto developer adjustment (Initial setting of toner 
density when replacing developer)
10
Polygon motor operation check 
26
01
Job separator setting
02
Size setting
03
Auditor setting
04
Copier duplex setting
05
Count mode setting
06
Destination setting
07
Machine condition check
08
Manual transfer shaking countermeasures setting
18
Toner save mode setting
20
Job separator paper exit mode setting
22
Language setting clear
30
CE mark conformity control ON/OFF
31
Auditor mode exclusive setup
36
Cancel of stop at maintenance life over
37
Cancel of stop at developer life over
39
Memory capacity check
42
Transfer ON/OFF timing control setting
43
Side void amount setting
51
Copy temporary stop function setting
54
LCD contrast PWM duty setting
56
Life correction ON/OFF setting
60
[FAX] key Enable/Disable setting
69
Toner near end environment setting
73
Toner save setting display/non-display
74
Total counter display change setting
30
01
Paper sensor status display
41
01
Document size detection photo sensor check
02
Document size detection photo sensor detection level 
adjustment
03
Document size detection photo sensor light receiving/
detection level check
04
Detection level adjustment when the document size is 
settled(15degrees - 20degrees)
42
01
Developing counter clear
Main 
code
Sub 
code
Contents
MX-M182 SIMULATIONS 7-2
<Execution inhibit conditions>
*1) Execution is inhibited when the duplex setup is OFF and other than 
RSPF is set. 
*2) Execution is inhibited when OC.
*3) Execution is inhibited when SPF. (Not RSPF)
*4) Execution is inhibited when the job separator is not installed.
*5) Execution is inhibited when the model is not provided with the 
CRUM. 
*6) Execution is inhibited when the duplex setup is OFF. 
43
01
Fusing temperature setting 1
02
Fusing temperature setting 2
03
Fusing temperature setting 3
04
Fusing temperature setting 4
12
Standby mode fusing fan rotation setting
13
Paper interval control allow/inhibit setting
44
01
Enable/Disable setting of toner density control 
correction
16
Toner density control data check and toner density 
correction quantity display
34
Transfer current setting
46
02
Copy density adjustment (600dpi)
10
Copy exposure level adjustment, individual setting 
(Text) 600dpi
11
Copy exposure level adjustment, individual setting 
(Photo) 600dpi
12
Density adjustment in the FAX mode 
(Collective adjustments)
13-16 Density adjustment in the FAX mode 
(Individual adjustments)
19
Exposure mode setting
(Gamma table setting/AE operation mode setting/
Photo image process setting)
20
SPF/RSPF exposure correction *2
29
Image contrast adjustment (600dpi)
30
AE limit setting
31
Image sharpness adjustment
39
FAX IMAGE adjustment
48
01
Main/sub scanning magnification ratio adjustment
05
SPF/RSPF mode sub scanning magnification ratio 
adjustment in copying *2
08
FAX magnification ratio adjustment (scan)
09
FAX magnification ratio adjustment (print)
49
01
Flash ROM program writing mode (MCU)
02
Flash ROM program writing mode (NNB)
50
01
Image lead edge adjustment
06
Copy lead edge position adjustment (SPF/RSPF) *2
8
FAX lead edge adjustment (scan)
10
Print off-center adjustment
12
Document off-center adjustment 
18
Memory reverse position adjustment in duplex copy *1
19
Rear edge void adjustment in duplex copy *5
51
02
Resist amount adjustment
53
08
SPF/RSPF scanning position automatic adjustment *2
61
02
Laser power correction ON/OFF (Invalidity)
03
HSYNC output check 
63
01
Shading check
64
01
Self print
65
10
Key ACK time setting display/non-display setting
11
Info lamp setting
Main 
code
Sub 
code
Contents
66
01
FAX soft SW setting
02
FAX soft SW initializing
03
FAX PWB memory check
04
Signal send mode
06
Confidential pass code print
07
Image memory content output
10
Image memory contents clear
11
300bps signal send
13
Dial number registration
17
DTMF signal send
21
FAX information print
24
FAST SRAM clear
30
TEL/LIU status change check
31
TEL/LIU setting
32
Receive data check 
33
Signal detection check 
34
Communication time measurement
37
Speaker sound volume adjustment
38
Time setting/check
42
PC program writing
43
PIC adjustment value writing
52
Pseudo ringer check 
67
50
USB reception speed adjustment
Main 
code
Sub 
code
Contents
MX-M182 SIMULATIONS 7-3
4. Contents of simulations
Main 
code
Sub 
code
Contents
Remark
01
01
Mirror scanning operation
Used to check the operations of the scanner unit and its control circuit. 
Enter the number of times and the magnification ratio, and press [OK] key to operate the scanner unit. The 
speed is variable according to the specified magnification ratio. The number of scanning can be specified by 
entering a value to the right lower section of the LCD.
•Setting range of magnification ratio: 25%-400%
•Setting range of the number of scanning: 0-999 (When 0 is set, it means unlimited. )
Used to display the status (ON/OFF) of the mirror HP sensor on the LCD during scanning. (Highlighted at 
ON)
"EXEC" is displayed to indicate execution is in process. The scan counter is displayed above "EXEC." This 
counter is counted up even in simulation.
 The copy lamp is lighted during scanning.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Returns to the sub code input window.
[C] key: Input value clear
Numeric keys: Input of the number of scanning
02
Mirror home positions sensor (MHPS) status display
Used to monitor the mirror home position sensor and display the ON/OF status of the sensor on the LCD.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Returns to the sub code input window.
Sim1-1 SCAN CHECK
MHPS
[OK] key or [START] Key
MHPS sensor status
Scan counter
(Scan number input window)
(Execution
         window)
Highlighted during execution
ZOOM
100%
5
123
Sim1-1 SCAN CHECK
ZOOM
100%
EXEC
123
MHPS
Set the scan magnification ration.
This magnification ratio accords with the scan speed
in actual copying. The setting range is 25% - 400%. 
Specify the scan number to be performed. 
The setting range is 0 - 999. When 0 is set,
the number is unlimited.
115%
100%
  86%
115%
100%
  86%
Sim1-2 SENSOR CHECK
MHPS
MHPS(MIRROR HOME POSITION SENSOR)
ON :Highlight 
display
OFF :Normal 
display
MX-M182 SIMULATIONS 7-4
02
01
Single Paper Feeder(SPF)/Reversing single pass feeder(RSPF)aging
Used to check the operations of the SPF/RSPF unit and its control circuit.
Enter the magnification ratio and press[OK] key or [START] key to drive the SPF/RSPF unit at the speed 
corresponding to the setting.
*
When [INTERRUPT] key is press, the simulation is terminated and the machine returns to the sub code 
input window. 
*
When [CA] key is pressed, the simulation is terminated and the machine exits the simulation mode. 
02
SPF/RSPF sensor status display
Used to display the sensor status in the SPF/RSPF section. An active sensor is highlighted.
[CA] key: Exits the simulation mode.
[INTERRUPT] key: Returns to the sub code input window.
Only when the SPF/
RSPF is installed.
03
SPF/RSPF motor operation check
Used to check the operation of the SPF/RSPF motor and its control circuit. When this simulation is 
executed, the initial menu shown below is displayed. Select the magnification ratio to drive the motor.
[CA] key: The SPF/RSPF motor is stopped, and the machine exits the simulation mode. 
[INTERRUPT] key: The SPF/RSPF motor is stopped, and the machine returns to the sub code input window.
Only when the SPF/
RSPF is installed.
Main 
code
Sub 
code
Contents
Remark
Sim2-1 SPF AGING
115%
100%
  86%
1SIDE
2SIDE
[OK] key or [START] Key
(Magnification ratio selection window)
ZOOM
100%
EXEC
Sim2-1 SPF AGING
115%
100%
  86%
1SIDE
2SIDE
(Execution
         window)
ZOOM
100%
EXEC
Select the scan magnification ratio (drive speed).
This also accords with the magnification ratio and
the speed in copying similarly to the OC.
The setting range is 50% - 200%.
"EXEC" is highlighted during execution.
Sim2-2 SENSOR CHECK
SPFP
OCCV
POUT
SPFC
L1
L2
W0
W1
W2
W3
Displayed name 
: Sensor name
SPFP 
:SPF document transportation sensor
OCCV 
:SPF unit (OC cover) open/close sensor
POUT 
:SPF paper exit sensor
SPFC 
:SPF paper feed cover open/close sensor
L1 
:SPF paper length sensor 1
L2 
:SPF paper length sensor 2
W0 
:SPF document set sensor
W1 
:SPF paper width sensor (small) 
W2 
:SPF paper width sensor (middle)
W3 
:SPF paper width sensor (large)
Sim2-3 OUTPUT CHECK
Sim2-3 OUTPUT CHECK
115%
100%
  86%
[OK] key or [START] Key
(Initial window = Magnification ratio selection window)
ZOOM
100%
EXEC
115%
100%
  86%
ZOOM
100%
EXEC
(Execution
         window)
Select the scan magnification ratio (drive speed).
This also accords with the magnification ratio and
the speed in copying.
The setting range is 50% - 200%.
"EXEC" is highlighted during execution.
Page of 127
Display

Click on the first or last page to see other MX-M182 / MX-M182D (serv.man5) service manuals if exist.