DOWNLOAD Sharp MX-M182 / MX-M182D (serv.man5) Service Manual ↓ Size: 9.62 MB | Pages: 127 in PDF or view online for FREE

Model
MX-M182 MX-M182D (serv.man5)
Pages
127
Size
9.62 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Service Manual December 2011.
File
mx-m182-mx-m182d-sm5.pdf
Date

Sharp MX-M182 / MX-M182D (serv.man5) Service Manual ▷ View online

MX-M182 ADJUSTMENT 6-2
(3) Developing bias voltage check
Note: Use a digital multi-meter with an internal resistance of 10M
 or 
more.
1) Set the digital multi-meter range above 500 Vdc. 
2) Put the test rod of the digital multi-meter on the developing bias 
voltage output check pin. 
3) Turn on the power, execute SIM25-1.
<Specification>
(4) Grid bias voltage check
Note: Use a digital multi-meter with an internal resistance of 10M
 or 
more.
1) Set the digital multi-meter range above 600 Vdc.
2) Put the test rod of the digital multi-meter on the grid bias voltage 
output check pin. 
3) Turn on the power. 
(The voltage is outputted in the grid bias High output mode during 
warming up, and in the grid bias Low output mode when warming up 
is completed.)
<Specification>
B. Mechanism section
(1) Image position adjustment
a. OC image lead edge position adjustment (SIM 50-1)
Note:In advance to this adjustment, the sub scanning magnification ratio 
adjustment must be performed.
1) Set a scale on the OC table as shown below.
2) Make a copy.
3) Check the copy output. If necessary, perform the following 
adjustment procedures.
4) Execute SIM 50-01. 
Select a desired mode with the arrow keys, enter the adjustment 
value with 10-key, and press [OK] key.
When [START] key is pressed, a sheet is printed.
<Adjustment specification>
5) Set the OC lead edge position set value (RRC-A) to [1]
The OC image scanning start position is shifted inside the document 
edge.
6) Set the main cassette lead edge void adjustment value (DEN-A)* to [1]
The lead edge void becomes the minimum.
Mode
 Specification
Developing bias voltage
 DC - 400±10V
Mode
 Specification
Grid bias LOW
 DC - 380±8V
Grid bias HIGH
 DC - 525±10V
Adjustment 
mode
 SIM
 Display 
text array
Set
 value
Spec
 value
 Set
range
OC image lead 
edge position
 SIM
50-1
RRC-A
R/0.1
Lead edge 
void:
1 - 4mm
Image loss: 
3mm or 
less
 1 - 99
Main cassette 
print start 
position
TRAY1
H/0.1
2nd cassette 
print start 
position
 TRAY2
Multi bypass 
tray print start 
position
 MFT
Lead edge void
DEN-A
B/0.05
(Mode selection window 1)
Sim50-1 LEAD EDGE
1:TRAY1
2:TRAY2
3:MFT
1/2     [      1-  99]
50
 
50 
50 
50
(Mode selection window 2)
Sim50-1 LEAD EDGE
4:DEN-A
5:RRC-A
6:DEN-B
2/2     [      1-  99]
50 
1
 
50 
50
Ready to copy.
S
100%
A4
(Copy start window)
Copies in progress.
S
100%
A4
(Copy execution window)
MX-M182 ADJUSTMENT 6-3
7) Set the main cassette print start position value (TRAY1) to [1] and 
make a copy.
The print start position is shifted inside the document edge.
8) Measure the image loss R of the copied image. Enter the set value of 
the image scanning lead edge position (RRC-A) again.
• 1 step of the set value corresponds to about 0.1mm shift.
• Calculate the set value from the formula below.
R/0.1(mm) = Image loss set value
 <R: Image loss measurement value (mm)>
Example:
4/0.1 = 40 = about 40
Note: If the set value is not obtained from the above formula, perform the 
fine adjustment.
9) Measure the distance H between the paper lead edge and the image 
print start position. Set the image print start position set value 
(TRAY1) again.
• 1 step of the set value corresponds to about 0.1mm shift.
• Calculate the set value from the formula below.
H/0.1(mm) = Image print start position set value
 <H: Print start position measurement value (mm)>
Example:
5/0.1 = 50 = about 50
Note: If the set value is not obtained from the above formula, perform the 
fine adjustment.
10) Set the lead edge void adjustment value (DEN-A)* again.
• 1 step of the set value corresponds to about 0.1mm shift.
• Calculate the set value from the formula below.
B/0.05 (mm) = Lead edge void adjustment value
 <B: Lead edge void (mm)>
Example:
When setting the lead edge void to 2.5mm
:2.5 /0.05 = about 50
Note:If the set value is not obtained from the above formula, perform the 
fine adjustment.
b. SPF image lead edge position adjustment (SIM50-6)
1) Set a scale on the OC table as shown below.
Note:Since the printed copy is used as a test chart, put the scale in 
parallel with the edge lines.
2) Make a copy, Then use the copy output as an original to make an 
SPF copy again.
3) Check the copy output. If necessary, perform the following 
adjustment procedures.
4) Execute SIM 50-6.
5) Set the SPF lead edge position set value (SIDE1) so that the same 
image is obtained as that obtained in the previous OC image lead 
edge position adjustment.
5
10
5mm
4mm
*
The dimension varies depending on the model.
10
5mm
0mm
5
*
 The scanning edge is set. 
   (A line may be printed by scanning the document edge.)
 
5
10
0mm
0mm
*
Fit the print edge with the paper edge, and perform the 
  lead edge adjustment. 
5
10
2.5mm
2.5mm
(Mode selection window)
Ready to copy.
S
100%
A4
(Copy start window)
Copies in progress.
S
100%
A4
(Copy execution window)
Sim50-6  SPF EDGE
1:SIDE1
2:SIDE2
3:END EDGE
     [      1-  99]
50
 
50 
50 
50
MX-M182 ADJUSTMENT 6-4
<Adjustment specification>
c. Rear edge void adjustment (SIM50-1, SIM50-19)
1) Set a scale as shown in the figure below.
2) Set the document size to A4 (8.5" x 11"), and make a copy at 100%.
3) If necessary, perform the following adjustment procedure.
4) Execute SIM50-01 and select "DEN-B" with the arrow keys.
The currently set adjustment value is displayed.
5) Enter the set value and press the start key. The correction value is 
stored and a copy is made.
<Adjustment specification>
d. Paper off center adjustment (SIM50-10)
1)  Set a test chart (UKOG-0089CSZZ) on the document table.
2) Select a paper feed port and make a copy. Compare the copy and 
the test chart. If necessary, perform the following adjustment 
procedure.
3) Execute SIM 50-10. After completion of warm-up, shading is 
performed and the currently set off center adjustment value of each 
paper feed port is displayed.
4) Enter the set value and press the start key. The correction value is 
stored and a copy is made.
<Adjustment specification>
e. Side edge void area adjustment (SIM26-43)
Note:Before performing this adjustment, be sure to check that the paper 
off center adjustment (SIM 50-10) is completed.
1) Set a test chart (UKOG-0089CSZZ) on the document table.
2) Select a paper feed port and make a copy. Compare the copy and 
the test chart. If necessary, perform the following adjustment 
procedure.
3) Execute SIM 26-43 and set the density mode to SIDE VOID (L), 
SIDE VOID (R).
The currently set adjustment value is displayed.
4) Enter the set value and press the start key. The correction value is 
stored.
<Adjustment specification>
Adjustment mode
 SIM
Display 
text 
array
 Set value  Spec value
 Set 
range
SPF image lead 
edge position
(1st print surface)
 SIM
50-6
SIDE1 1 step: 
0.1mm 
shift
Lead edge 
void:
1 - 4mm
Image loss: 
3mm or 
less
 1 - 99
Mode
 SIM
 Display 
text array
 Set value
 Specifi- 
cation
 Set 
range
Rear edge void
 SIM 
50-1
DEN-B
1 step: 
0.1mm shift
4mm or 
less
 1 - 99
 
A4(8.5"  x 11")
Paper rear edge
Scale image
Paper rear edge
Void amount (Standard value: 4mm or less) 
Adjustment 
mod
SIM
Display 
text array
 Set value
 Specifi- 
cation
 Set 
range
Tray1
 SIM 
50-10
TRAY1
Add 1: 
0.1mm shift 
to R side. 
Reduce 1: 
0.1mm shift 
to L side.
Single:
Center
±2.0mm
 1 - 99
Tray2
TRAY2
Tray3
TRAY3
Tray4
TRAY4
Manual paper 
feed tray
BYPASS
Duplex 
(Second print 
surface)
DUPLEX
Adjustment 
mode
 SIM
Display 
text array
 Set value
 Specifi-
cation
 Set 
range
Side void (left)
26-43
SIDE 
VOID (L)
1 step: 
0.5mm shift
 0.5 - 4mm  1 - 99
Side void (right)
SIDE 
VOID (R)
Sim50-10 PRT. CENTER
1:TRAY1
2:TRAY2
3:TRAY3
1/2     [      1-  99]
50
 
50 
50 
50
Sim50-10 PRT. CENTER
4:TRAY4
5:BYPASS
6:DUPLEX
2/2     [      1-  99]
50
 
50 
50 
50
Sim26-43 SIDE  VOID
1:SIDE VOID(L)
2:SIDE VOID(R)
     [      0-  10]
3
 
3
3
MX-M182 ADJUSTMENT 6-5
(2) Main scanning direction (FR direction) distortion 
balance adjustment 
1) Remove the OC glass and the right cabinet.
2) Loosen the copy lamp unit wire fixing screw.
3) Manually turn the mirror base drive pulley and bring No. 2/3 mirror 
base unit into contact with the positioning plate. At that time, if the 
front frame side and the rear frame side of No. 2/3 mirror base unit 
are brought into contact with the positioning plate at the same time, 
the mirror base unit parallelism is proper. If one of them is in contact 
with the positioning plate, perform the adjustment of 4).
4) Loosen the set screw of the scanner drive pulley which is not in 
contact with No. 2/3 mirror base unit positioning plate.
5) Without moving the scanner drive pulley shaft, manually turn the 
scanner drive pulley until the positioning plate is brought into contact 
with No. 2/3 mirror base unit, then fix the scanner drive pulley.
6) Put No. 2/3 mirror base unit on the positioning plate again, push the 
projections on the front frame side and the rear frame side of the 
copy lamp unit to the corner frame, and tighten the wire fixing screw.
(1)
(1)
(2)
(4)
(3)
(3)
Wire fixing screw