DOWNLOAD Sharp MX-FX15 Service Manual ↓ Size: 598.64 KB | Pages: 57 in PDF or view online for FREE

Model
MX-FX15
Pages
57
Size
598.64 KB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / MX-FX15 Service Manual
File
mx-fx15.pdf
Date

Sharp MX-FX15 Service Manual ▷ View online

MX-FX15  FAX SOFTWARE SWITCH  2 – 1
MX-FX15
Service Manual
 
[2] FAX SOFTWARE SWITCH
1.  List
Lines
SW 
No.
Bit 
No.
Item
SW selection and function
System settings
1
1-8
Country code
Control is performed according to the set country code.
The destination setting that is set in SIM66-2 as the image send function is 
reflected.
The country code setting cannot be directly made from this SW.
SW 
No.
Bit 
No.
Item
SW selection and function
System settings
2
1-4
Calling
Make time (10PPS) 
setting
Setting of make time when dialling at 10PPS.
Make time can be set from 29 to 44ms in 1ms increments by binary inputting N 
over the range of 0 to 15 (N + 29ms).
Adjustment value
5-8
Calling
Break time setting 
(10PPS) 
Setting of break time when dialling at 10PPS. 
Break time can be set from 56 to 71ms by in 1ms increments binary inputting N 
over the range of 0 to 15 (N + 56ms).
Adjustment value
3
1-4
Calling
Minimum pause time 
(10PPS) setting
Setting of minimum pause time when dialling at 10PPS.
Minimum pause time can be set from 800 to 950ms in 10ms increments by 
binary inputting N over the range of 0 to 15 (N x 10ms + 800ms).
Adjustment value
5-8
Calling
Minimum pause time 
(20PPS) setting
Setting of minimum pause time when dialling at 20PPS.
Minimum pause time can be set from 450 to 600ms in 10ms increments by 
binary inputting N over the range of 0 to 15 (N x 10ms + 450ms).
Functions only in China and Thailand.
Adjustment value
4
1-4
Calling
Make time (20PPS) 
setting
Setting of make time when dialing at 20PPS.
Make time can be set from 9 to 24ms by binary inputting N over the range of 0 
to 15 (N + 9ms).
Functions only in China and Thailand.
Adjustment value
5-8
Calling
Break time setting 
(20PPS)
Setting of break time when dialing at 20PPS.
Break time can be set from 26 to 41ms by binary inputting N over the range of 0 
to 15 (N + 26ms).
Functions only in China and Thailand.
Adjustment value
5
1-4
Calling
Setting of DTMF send 
level (high group)
This sets the send level of high area and low area DTMF signals in units of 1dB.
Setting can be made over the range of 0dB to 15dB in 1dB increments by 
binary inputting.
Adjustment value
5-8
Not used
6
1-4
Calling
Setting of DTMF send 
level (low group)
High group - Low 
group: level difference
This sets the difference between the DTMF signal high area level and low area 
level in units of 0.5dB.
Setting can be made over the range of -2.0dB to 5.5dB in 0.5dB increments by 
binary inputting. 
High group - Low group
"0 0 0 0": -2.0dB
"1 0 0 0": 2.0dB
"0 0 0 1": -1.5dB
"1 0 0 1": 2.5dB
"0 0 1 0": -1.0dB
"1 0 1 0": 3.0dB
"0 0 1 1": -0.5dB
"1 0 1 1": 3.5dB
"0 1 0 0": 0.0dB
"1 1 0 0": 4.0dB
"0 1 0 1": 0.5dB
"1 1 0 1": 4.5dB
"0 1 1 0": 1.0dB
"1 1 1 0": 5.0dB
"0 1 1 1": 1.5dB
"1 1 1 1": 5.5dB
Adjustment value
5-8
Not used
7
1-8
Calling
Setting of DTMF 
minimum pause time
This sets the minimum pause time between DTMF signals when sending DTMF 
signals.
Minimum pause time can be set by binary inputting N over the range of 0 to 255 
(1ms x N).
Setting can be made over the range of 50ms to 255ms in 1ms increments by 
binary inputting.
When SW15-3,4 are set to other than "MODEM fixed," the set value less than 
54ms is considered as 54ms.
The initial value is reverted to if a value outside of the setting range is set.
Adjustment value
MX-FX15  FAX SOFTWARE SWITCH  2 – 2
8
1-5
Calling
DTMF signal send time
This sets the time that DTMF signals are sent when sending DTMF signals.
Send time can be set over the rage of 70 to 310ms in 10ms increments by 
binary inputting N from 0 to 31 (110ms x N).
The initial value is reverted to if a value outside of the setting range is set.
Adjustment value
6, 7
Calling
Dial call waiting time
This sets the waiting time from the end of line connection to the start of dial call 
at times of automatic dial calling.
"00": 3.5 seconds
"01": 4 seconds
"10": 5 seconds
"11": 6 seconds
This only functions when dial tone detection is OFF.
Adjustment value
8
Calling
Line current detection 
at times of dial calling
Setting to determine whether or not to call dial following detection of line current 
during line connection at times of automatic dial calling.
"1": No
"0": Yes
In cases where the setting is "Yes" but no line current can be detected, dial is 
not called but the busy re-call procedure is followed.
Setting
9
1
Calling
Manual calibration 
setting when sending
Setting to execute the manual calibration or not when sending.
In case of an abnormal current waveform, the auto calibration fails and the 
DTFM signal is deformed. This setting provides the countermeasure against 
that problem.
"0": Execute
"1": Not execute
Setting
2
Call arrival
Manual calibration 
setting when a signal
arrives
Setting to execute the manual calibration or not when a signal arrives.
In case of an abnormal current waveform, the auto calibration fails and the 
transmission is affected. This setting provides the countermeasure against that 
problem.
"0": Execute
"1": Not execute
Setting
3-5
Not used
6
Calling
No. 2 dial tone 
detection
Setting of ON/OFF of No.2 dial tone detection function.
"0": OFF (No. 2 dial tone detection is not performed.)
"1": ON (No. 2 dial tone detection is performed.)
Setting
7
Calling
Dial tone detection
When the setting is "Yes," the dial is sent following confirmation of detection of 
the dial tone when the line is captured; and when the setting is "No," dial is sent 
without a dial tone because no confirmation of dial tone detection is carried out 
after line capture.
"0": No
"1": Yes
Setting
8
Calling
Dial tone ON detection 
time (during 
continuous detection)
This sets the waiting time from the end of line connection to the start of dial call 
at times of automatic dial calling.
"0": 1.5 seconds
"1": 1 seconds
Adjustment value
10
1-4
Calling
Lower limit of dial tone 
ON/OFF detection time 
(during intermittent 
detection)
This sets the lower limit time for detection of dial tone ON/OFF time.
Setting can be made over the range of 40ms to 490ms in 30ms increments by 
binary inputting.
(N x 30ms) + 40ms
This is only valid during intermittent DT detection.
Adjustment value
5-8
Calling
Upper limit of dial tone 
ON/OFF detection time 
(during intermittent 
detection)
This sets the upper limit time for detection of dial tone ON/OFF time.
Setting can be made over the range of 400ms to 1900ms in 100ms increments 
by binary inputting.
(N x 100ms) + 400ms
This is only valid during intermittent DT detection.
Adjustment value
11
1-4
Calling
External line 
connection number 
setting 1 <First digit>
When No. 2 dial tone is detected, this area is compared with the external in 
connection number. If they match, the units waits for No. 2 dial tone.
Up to two external line connection numbers (max. 4 digits) can be registered as 
options.
The first digit of the external line connection number 1 is set.
The numbers and codes which can be registered are as follows.
0 - 9 / * (a) / # (b) / – (pause) (c) / Not used for this digit and after (d) / 
Any is OK (f)
When set to [e], it is considered as setting to [0].
Setting
5-8
Calling
External line 
connection number 
setting 1 <Second 
digit>
The second digit of the external line connection number 1 is set.
The numbers and codes which can be registered are as follows.
0 - 9 / * (a) / # (b) / – (pause) (c) / Not used for this digit and after (d) / 
Any is OK (f)
When set to [e], it is considered as setting to [0].
Setting
SW 
No.
Bit 
No.
Item
SW selection and function
System settings
MX-FX15  FAX SOFTWARE SWITCH  2 – 3
12
1-4
Calling
External line 
connection number 
setting 1 <Third digit>
The third digit of the external line connection number 1 is set.
The numbers and codes which can be registered are as follows.
0 - 9 / * (a) / # (b) / – (pause) (c) / Not used for this digit and after (d) / 
Any is OK (f)
When set to [e], it is considered as setting to [0].
Setting
5-8
Calling
External line 
connection number 
setting 1 <Fourth digit>
The fourth digit of the external line connection number 1 is set.
The numbers and codes which can be registered are as follows.
0 - 9 / * (a) / # (b) / – (pause) (c) / Not used for this digit and after (d) / 
Any is OK (f)
When set to [e], it is considered as setting to [0].
Setting
13
1-4
Calling
External line 
connection number 
setting 2 <First digit>
The first digit of the external line connection number 2 is set.
The numbers and codes which can be registered are as follows.
0 - 9 / * (a) / # (b) / – (pause) (c) / Not used for this digit and after (d) / 
Any is OK (f)
When set to [e], it is considered as setting to [0].
Setting
5-8
Calling
External line 
connection number 
setting 2 <Second 
digit>
The second digit of the external line connection number 2 is set.
The numbers and codes which can be registered are as follows.
0 - 9 / * (a) / # (b) / – (pause) (c) / Not used for this digit and after (d) / 
Any is OK (f)
When set to [e], it is considered as setting to [0].
Setting
14
1-4
Calling
External line 
connection number 
setting 2 <Third digit>
The third digit of the external line connection number 2 is set.
The numbers and codes which can be registered are as follows.
0 - 9 / * (a) / # (b) / – (pause) (c) / Not used for this digit and after (d) / 
Any is OK (f)
When set to [e], it is considered as setting to [0].
Setting
5-8
Calling
External line 
connection number 
setting 2 <Fourth digit>
The fourth digit of the external line connection number 2 is set.
The numbers and codes which can be registered are as follows.
0 - 9 / * (a) / # (b) / – (pause) (c) / Not used for this digit and after (d) / 
Any is OK (f)
When set to [e], it is considered as setting to [0].
Setting
15
1, 2
Calling
DT/BT detection level
This sets the minimum detection level for determining that dial tone and busy 
tone have been detected. Signal levels not larger than this setting are ignored.
"00": -43dB
"01": -35dB
"10": -33dB
"11": -30dB
DT, BT common
Adjustment value
3, 4
Calling
DT/BT detection 
frequency range 
setting
This sets the detection frequency range when detecting dial tone and busy 
tone.
Change the setting if dial tone and busy tone are erroneously detected.
"00": MODEM fixed (about 308Hz - 517Hz)
"01": 420Hz - 680Hz
"10": 360Hz - 440Hz
"11": 245Hz - 650Hz
For CTR21: 245Hz - 650Hz
Adjustment value
5
Calling
Busy tone detection
Setting to determine whether or not to detect the busy tone signal during 
automatic dial calling and when the external telephone simulated call sound is 
ringing.
"0": Detect
"1": Do not detect
Setting
6
Calling
Busy tone OFF non-
detection time
This sets the non-detection time on the busy tone OFF section.
Change the setting in cases where noise, etc. on the busy tone ON section 
adversely affects the ON section.
"0": 100ms
"1": 300ms
* Make shorter than the "busy tone OFF detection time."
Adjustment value
7, 8
Calling
Lower limit of busy 
tone ON detection time
This sets the lower limit time of the ON section when detecting frequency of the 
busy tone signal.
If busy tone signals are not detected in excess of this time, do not count as 1 
pulse.
"00": 250ms
"01": 140ms
"10": 450ms
"11": 350ms
Adjustment value
SW 
No.
Bit 
No.
Item
SW selection and function
System settings
MX-FX15  FAX SOFTWARE SWITCH  2 – 4
16
1, 2
Calling
Upper limit of busy 
tone ON detection time
This sets the upper limit time of the ON section when detecting frequency of the 
busy tone signal.
If busy tone signal is detected in excess of this time, do not count as 1 pulse.
"00": 750ms
"01": 650ms
"10": 1000ms
"11": 2850ms
Adjustment value
3, 4
Calling
Lower limit of busy 
tone OFF detection 
time
This sets the lower limit time of the OFF section when detecting frequency of 
the busy tone signal.
If busy tone OFF signals are not detected in excess of this time, do not count as 
1 pulse.
"00": 250ms
"01": 140ms
"10": 450ms
"11": 350ms
Adjustment value
5, 6
Calling
Upper limit of busy 
tone OFF detection 
time
This sets the upper limit time of the OFF section when detecting frequency of 
the busy tone signal.
If busy tone signal is detected in excess of this time, do not count as 1 pulse.
"00": 750ms
"01": 650ms
"10": 1000ms
"11": 2850ms
Adjustment value
7, 8
Not used
17
1-4
Call arrival
Call signal OFF non-
detection time
This sets the time for ignoring OFF signals and regarding ON time to be 
continuous following ON detection of the call signal (CI).
This is intended to treat the PBX call signal "ring-ring" as a single call signal.
Setting can be made over the range of 0ms to 1500ms in 100ms increments by 
binary inputting.
Adjustment value
5-8
Call arrival
Lower limit of call 
signal ON time
This sets the minimum ON time for detecting call signal (CI) pulses (number of 
pulses). 1 pulse is counted if the CI signal remains ON for the set ON time or 
longer.
Setting can be made over the range of 150ms to 300ms in 10ms increments by 
binary inputting.
Adjustment value
18
1-4
Call arrival
Upper limit of call 
signal ON time
This sets the maximum ON time for detecting call signal (CI) pulses (number of 
pulses). Disregard and do not count as 1 pulse if the CI signal remains ON for 
the set ON time or longer.
Setting can be made over the range of 3000ms to 4500ms in 100ms 
increments by binary inputting.
Adjustment value
5-8
Call arrival
Lower limit of call 
signal OFF time
This sets the minimum OFF time for detecting call signal (CI) pulses (number of 
pulses). 1 pulse is counted if the CI signal remains OFF for the set OFF time or 
longer.
Setting can be made over the range of 100ms to 1500ms in 100ms increments 
by binary inputting.
Setting range
When 0 is set, initial value 700ms operation takes place.
Adjustment value
19
1, 2
Call arrival
Upper limit of call 
signal OFF time
This sets the maximum waiting time from detection of the call signal (CI) pulse 
(number of pulses) to detection of the next CI signal pulse.
Accordingly, if the next CI signal pulse is not detected within this time, the 
number of calls up to now is cleared.
"00": 6.5 seconds
"01": 10 seconds
"10": 15 seconds
"11": 20 seconds
Adjustment value
3
Call arrival
CI clear judgment
Setting of the judgment of CI signal 1 cycle.
"1": Cleared only when the max. cycle is exceeded. (The min. cycle is 0.)
"0": Cleared when outside the range of 1 cycle. (The min. and the max. cycles 
are set with other soft switches.)
4, 5
Call arrival
Filter time when the CI 
signal is detected. 
The detection sampling time of the CI signal is set in the CI signal detection 
setting.
"00": 10ms
"01": 5ms
"10": 15ms
"11": 20ms
6-8
Not used
20
-
23
1-8
Not used
SW 
No.
Bit 
No.
Item
SW selection and function
System settings
Page of 57
Display