DOWNLOAD Sharp MX-FX10 Service Manual ↓ Size: 2.42 MB | Pages: 73 in PDF or view online for FREE

Model
MX-FX10
Pages
73
Size
2.42 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Service Manual.
File
mx-fx10.pdf
Date

Sharp MX-FX10 Service Manual ▷ View online

MX-FX10 SIMULATIONS, FAX SOFTWARE SWITCH 4-7
66
4
Signal send mode
Used to send signals to the line and the machine speaker by setting the signal number. (Signal send is 
continued until interruption is instructed by pressing RETURN key.) The signal send level is selected from 
0db and the soft SW values. Since the level setting is not required for 01 and 31 - 35, the selection menu 
does not appear. The signal send level is returned to the soft SW set value before execution of the mode 
when completing the mode.
6
Print pass code print
Used to print the confidential ID table (confidential box number, confidential box name, confidential pass 
code). Sharp mode confidential information is printed separately.
7
Image memory content print
Used to print all the image data (confidential receive contents, remote send images, and images which are 
not sent yet) in the image memory of the FAX section. The printed images are remained in the memory after 
printing.
Main 
code
Sub 
code
Contents
Remark
Sim66-4 SIGNAL OUT
Sim66-4 SIGNAL OUT
Sim66-4 SIGNAL OUT
Sim66-4 SIGNAL OUT
Sim66-4 SIGNAL OUT
SIGNAL SELECT
(1 - 35)
1:NO SIGNAL
2:33600bps(V34)
3:31200bps(V34)
(1 - 35)
XX
After selection with numeric keys
[OK] key
[OK] key
[OK] key
[BACK] key
33600bps(V34)
1:MAX
2:SOFT SW.
(1 - 2)
X
33600bps(V34)
0dB
EXEC
33600bps(V34)
PRESS BACK TO STOP
EXEC
Sim66-4 SIGNAL OUT
34:DP MAKE
35:DP BREAK
(1 - 35)
XX
After pressing 
[OK] key
SIM66-4 initial window
[CA] key
: Simulation cancel
[INTERRUPT] key: Sub code input window
[C] key
: Input clear
          key
: Page select
Numeric keys
: Number input and item selection
[OK] key
: Input value settlement and execution
[START] key
: Input value settlement
[BACK] key
: Signal send stop
The window is switched with the up and down keys.
Input and switching the window are irrelevant.
Not highlighted with an input of a value.
The window is not switched, either.
When "1: NO SIGNAL" or "31: PSEUDO RNG" - "33: R.B. TONE NONE"
is selected, "0dB" and "SOFT SW" are not selected.
When one of these is selected, the second line is the signal name,
the third and fourth lines are empty, and the fifth line is EXEC display. 
1sec later
Sim66-6
PASS CODE
Sim66-6
PASS CODE
Sim66-6
PASS CODE
PRINT STORED
[OK] key
[OK] key
[OK] key
PRINT CONF.
               EXEC
NO DATA
Sim66-6
PASS CODE
CAN NOT PRINT
1sec later
1sec later
1sec later
[CA] key
: Simulation cancel
[INTERRUPT] key : Sub code input
window
[OK] key
: Settlement
[START] key
: Settlement
[C] key
: Disable
[BACK] key
: Disable
Sim66-7 PRINT MEMORY
Sim66-7 PRINT MEMORY
Sim66-7 PRINT MEMORY
PRINT STORED
PRINT IMAGE MEMORY
               EXEC
NO DATA
Sim66-7 PRINT MEMORY
CAN NOT PRINT
(When there is no image memory)
[OK] key
[OK] key
[OK] key
1sec later
1sec later
1sec later
[CA] key
: Simulation cancel
[INTERRUPT] key : Sub code input
window
[OK] key
: Settlement
[START] key
: Settlement
[C] key
: Disable
[BACK] key
: Disable
MX-FX10 SIMULATIONS, FAX SOFTWARE SWITCH 4-8
66
10
Image memory contents clear
Used to clear all the image data (including confidential receive contents) in the image memory of the FAX 
section. The management table is also cleared (initialized) at the same time.
11
300bps signal send
Used to send the specified signal at the speed of 300bps by setting the signal number. (Signal send is 
continued until interruption is instructed by pressing RETURN key.) The signal send level is selected from 
0db and soft switch set values. The signal send level is returned to the sot SW set value before execution of 
the mode after completion of the mode.
13
Dial test
Used to send the dial pulse and the DTMF signal, and perform the dial pulse make time adjustment and the 
DTMF signal send level adjustment according to necessity.
Main 
code
Sub 
code
Contents
Remark
Sim66-10 IMAGE CLR
[OK] key
Sim66-10 IMAGE CLR
Sim66-10 IMAGE CLR
CLEAR IMAGE MEMORY
ARE YOU SURE? EXEC
CLEAR IMAGE MEMORY
EXEC
CLEARED IMAGE MEM.
DO POWER OFF
Sim66-10 IMAGE CLR
CLEARED
Power source OFF/ON
Simulation code input window
Completion 
of execution
(Highlighted 
 during execution)
Completion of execution
(Highlighted during execution)
After pressing 
[OK] key,
during execution
With prints
Without prints
[CA] key
: Simulation cancel
[INTERRUPT] key : Sub code input
window
[OK] key
: Settlement
[BACK] key
: Simulation code input window
[START] key
: Settlement
[C] key
: Disable
[BACK] key
Sim66-11 300bps SIG.
Sim66-11 300bps SIG.
[OK] key
Sim66-11 300bps SIG.
Sim66-11 300bps SIG.
SIGNAL LEVEL
1:MAX
2:SOFT SW.
( 1 - 2 ) 
X
1:NO SIG.
4:00000
2:11111
5:010101
3:11110
6:00001
( 1 - 6 ) 
X
NO SIGNAL
EXEC
SIM66-11 initial window
OUTPUTING SIGNAL
PRESS BACK TO STOP
EXEC
After selection with numeric keys
[OK] key
[OK] key
After selection
with numeric keys
After pressing [OK] key,
during execution
[BACK] key
[CA] key
: Simulation cancel
[INTERRUPT] key : Sub code input window
[C] key
: Input clear
          keys
: Page switch
Numeric keys
: Item selection
[OK] key
: Input value settlement and execution
[START] key
: Input value settlement
[BACK] key
: Signal send stop
Sim66-13 DIAL TEST
1:PULSE 10pps
2:PULSE 20pps
3:DTMF
( 1-3 )
X
SIM66-13 initial window
SIM66-13 initial window
Select with numeric key 
and press [OK] key.
Select with numeric keys
and press [OK] key.
SENDING 10 pps Yyms
INPUT DIAL #
   XXXXXXXXXXXX
EXEC
[OK] key
[OK] key
Sim66-13 DIAL TEST
PULSE 10pps
INPUT MAKE TIME
YY
( 26-41 )
YY
Sim66-13 DIAL TEST
PULSE 10pps
 Yyms
INPUT DIAL #
   XXXXXXXXXXXXX
EXEC
Sim66-13 DIAL TEST
SEND 10 pps
Yyms
INPUT DIAL #
   XXXXXXXXXXXXX
EXEC
Sim66-13 DIAL TEST
Sim66-13 DIAL TEST
INPUT HIGH LEVEL
DTMF    SOFT SW.
Y
( 0-21 )
XX
Sim66-13 DIAL TEST
SELECT HIGH LEVEL
1:DEFAULT
2:SOFT SW.
Y
( 1-2 )
X
Sim66-13 DIAL TEST
INPUT LOW LEVEL
DTMF    SOFT SW.
Y
( 0-15 )
XX
Sim66-13 DIAL TEST
DTMF HIGH:XX LOW:YY
INPUT DIAL #
   XXXXXXXXXXXXX
EXEC
Sim66-13 DIAL TEST
DTMF HIGH:XX LOW:YY
INPUT DIAL #
   XXXXXXXXXXXXX
EXEC
Sim66-13 DIAL TEST
SELECT LOW LEVEL
1:DEFAULT
2:SOFT SW.
Y
( 1-2 )
X
After selection
with numeric key
[OK] key
[OK] key
After selection with numeric key
[OK] key
[OK] key
[OK] key
[OK] key
[OK] key
After selection 
with numeric 
key
After selection 
with numeric 
key
[OK] key
The input of 
numeric key 
enters the 
fourth digit.
(If there are too 
many, scroll to the left.)
After pressing [OK] key, during execution
After pressing 
[OK] key, 
during 
execution
Completion of execution
(Highlighted during execution)
Completion of execution
(Highlighted during execution)
[CA] key
: Simulation cancel
[INTERRUPT] key: Sub code input window
[C] key
: Input clear
Numeric key
: Input of time and dial number
and selection of an item
[OK] key
: Settlement and execution of an input
[START] key
: Settlement of an input
[BACK] key
: Returns to the selection window
XXXXXXXX
: Input dial 
When "1" is selected
When "2" is selected
MX-FX10 SIMULATIONS, FAX SOFTWARE SWITCH 4-9
66
17
DTMF signal send
Used to select the signal send level from 0dB and the soft SW set values and specify a dial number to be 
sent. The DTMF signal of the specified dial number is sent continuously until the interrupt command is made 
by pressing RETURN key. When another dial number is specified during sending of the signal, the signal 
send level is returned to the soft SW set value before execution of the mode after completion of the mode.
19
SRAM backup
Used to back up and restore the SRAM contents.
21
FAX information print
Used to print the following FAX information.
Main 
code
Sub 
code
Contents
Remark
Sim66-17 DTMF SIG.
Sim66-17 DTMF SIG.
Sim66-17 DTMF SIG.
1:MAX
2:SOFT SW.
( 1-2 )
X
[OK] key
[OK] key
[BACK] key
INPUT DIAL #
X
EXEC
[CA] key
: Simulation cancel
[INTERRUPT] key : Sub code input window
[C] key
: Input clear and stop
Numeric keys
: Item selection, dial number input
[OK] key
: Input value settlement and execution
[START] key
: Input value settlement and execution
[BACK] key
: Signal send stop
SENDING SIGNAL
X
PRESS BACK TO STOP
EXEC
After selection 
with numeric key
The numeric key 
input enters 
the third digit. 
Completion of execution 
(Highlighted during execution)
SIM66-17 initial window
Sim66-19
BACK UP
Sim66-19
BACK UP
NO DATA
             
SRAM BACK UP
ARE YOU SURE?EXEC
Sim66-19
BACK UP
WRONG FAX VER.
Sim66-19
BACK UP
1:SRAM BACK UP
2:SRAM RESTORE
( 1-2 )
X
Sim66-19
BACK UP
SRAM BACK UP
FINISHED
Sim66-19
BACK UP
SRAM BACK UP
PRESS BACK TO STOP
SENDING
EXEC
[OK] key
[OK] key
[OK] key
[OK] key
[BACK] key
After inputting
1 or 2
After pressing 
[OK] key,
during execution
Completion of execution
(Highlighted during execution)
After pressing [OK] key, during execution
After pressing [OK] key, during execution
SIM66-19 initial window
[BACK] key
SIM66-19 initial window
[BACK] key
SIM66-19 initial window
[CA] key
: Simulation cancel
[INTERRUPT] key : Sub code input window
Numeric key
: Item selection
[OK] key
: Execution\
[START] key : Settlement of the input value
[BACK] key
: Returns to the selection window. 
[C] key
: Disable
Sim66-21 LIST
Sim66-21 LIST
Sim66-21 LIST
1:USER SW. LIST
2:SOFT SW. LIST
3:SYSTEM ERROR
(1 - 5)
X
SOFT SW. LIST
EXEC
PRINT  STORED
Sim66-21 LIST
4:PROTOCOL MONITOR
5:FAX SIMULATION
(1 - 5)
X
[OK] key
[OK] key
[OK] key
Sim66-21 LIST
CAN NOT PRINT
Printer Error
After selection with numeric keys
After selection 
with numeric
keys
After pressing 
[OK] key,
during 
execution
1sec later
SIM66-21 window
1sec later
SIM66-21 window
[CA] key
: Simulation cancel
[INTERRUPT] key : Sub code input window
Numeric key
: Item selection
[OK] key
: Settlement and execution
[START] key
: Input value settlement and executio
[BACK] key
: Returns to the selection window.
         keys
: Page switch
[C] key
: Disable 
MX-FX10 SIMULATIONS, FAX SOFTWARE SWITCH 4-10
66
24
FAST SRAN clear
Used to clear the FAST SRAM data.
30
TEL/LIU status change check
Used to display the change contents regardless of the soft SW setting when the status of the polarity 
inversion relay, the handset hook switch, or the external telephone hook switch is changed. The display of 
the changed status is remained until the interruption command is made by pressing RETURN key.
31
TEL/LIU setting
The following bit 0/1 is alternatively switched. At the same time, the target signal name is highlighted.
Main 
code
Sub 
code
Contents
Remark
Sim66-24 FAST CLR
Sim66-24 FAST CLR
[OK] key
Sim66-24 FAST CLR
INITIAL
EXEC
INITIALIZED
Sim66-24 FAST CLR
Not Supported
FAST Correspond
FAST NO Correspond
INITIAL
EXEC
[CA] key
: Simulation cancel
[INTERRUPT] key : Sub code input window
[OK] key
: Settlement
[START] key
: Settlement
[C] key
: Disable
[BACK] key
: Disable
After pressing 
[OK] key,
during 
execution
Completion of 
execution
(Highlighted during 
 execution)
1sec later
Simulation code input window
Sim66-30 TEL STAT.
Sim66-30 TEL STAT.
[OK] key
[BACK] key
SIM66-30 
initial window
EXEC
HS2 :XXX  HS1  :XXX
RHS :XXX  EXHS :XXX
PRESS BACK TO STOP
EXEC
XXX: ON or OFF
[CA] key
: Simulation cancel
[INTERRUPT] key : Sub code input window
[OK] key
: Settlement
[BACK] key
: Returns to the selection 
window
[START] key
: Settlement
[C] key
: Disable
After pressing 
[OK] key,
during 
execution
Sim66-31 TEL OUTPUT
Sim66-31 TEL OUTPUT
After selection
with numeric keys
[OK] key
[OK] key
[BACK] key
[BACK] key
[OK] key
Sim66-31 TEL OUTPUT
SIM72-3 initial window
SIM72-3 initial window
1:CION 2:150VON
3:EC
 4:S
(1 - 5)
X
1:CION
5:MSR
EXEC
1:CION
5:MSR
PRESS BACK TO STOP
EXEC
Sim66-31 TEL OUTPUT
5:MSR
(1 - 5)
X
Selection of two or more items can be made.
(The selected numbers are highlighted.)
Though numeric keys is pressed in the sequence
of "1 and 5" or "5 and 1," the display is made
in the sequence of the normal order
(1 and 5) when OK key is pressed.
Sim66-31 TEL OUTPUT
5:MSR
PRESS BACK TO STOP
EXEC
Sim66-31 TEL OUTPUT
5:MSR
EXEC
After pressing [OK] key,
during execution
After pressing [OK] key,
during execution
Switchable for 5 or more items
Switchable for 5 or more items
[CA] key
: Simulation cancel
[INTERRUPT] key : Sub code input window
Numeric keys
: Item selection
[OK] key
: Input value settlement and execution
[START] key
: Input value settlement and execution
[BACK] key
: Returns to the selection window
         keys
: Page switch
[C] key
: Input value clear. ON when highlighted.
Page of 73
Display