Sharp MX-FNX9 (serv.man15) Service Manual / Technical Bulletin ▷ View online
Sharp Electronics (UK) Ltd., Document Systems Support
3/5
- Change of the hole positions of Drawer Bracket (MX-PNX1)
- Identification of current/new Drawer Bracket
- Mylar affixation position (MX-PNX1)
4. Action:
From mid-September 2013 production
5. Parts Action:
Ref.
No.
Model
name
Version P/G No.
Current parts
New parts
Price
rank
Q'ty Parts
name
Effective
time
Inter-
change-
ability
Parts code
Parts code
1
MX-FNX9
MX-FNX1
MX-FNX1
ALL
13-18
0CW4141K085// 0CW4141K08501
BS
1
DUMMY PUNCH
UNIT
UNIT
2013/9
Mid
3
13-21
0CW4141K080B/ 0CW4141K08001
BD
BRACKET
UNIT
13-
0CW1035P301// 0CW4F521810// AF
MYLAR
MX-PNX1
1-9
0CW1035P102// 0CW1035P10201
AL
DRAWER
BRACKET
2-21
0CW1035P301// 0CW4F521810// AF
MYLAR
<Interchange>
1. Interchangeable.
4. Not interchangeable.
2. Current type can be used in place of new type.
New type cannot be used in place of current type.
5. Interchangeable if replaced with same types of
related parts in use.
3. Current type cannot be used in place of new type.
New type can be used in place of current type.
6. Others.
Parts marked with "
" is important for maintaining the safety of the set. Be sure to replace these parts with
specified ones for maintaining the safety and performance of the set.
Move the mounting
hole position of
Drawer to 1.5mm
lower side.
Modified parts: "N" mark is added.
Punch Unit
Protruded amount of Mylar
Before change: 1.8mm
After change: 2.9mm
Move the mounting
screw hole position of
Drawer to 1.5mm lower
side.
Mylar
Sharp Electronics (UK) Ltd., Document Systems Support
4/5
6. Field Action:
1. Remove the ejecting sponges (x6) mounted on the delivery follower roller of the delivery unit.
Pull out the ejecting sponge while
picking up with the nipper etc.
and then remove it.
Sharp Electronics (UK) Ltd., Document Systems Support
5/5
2. Remove the current Mylar on Entrance Upper Guide of Punch UN, and then affix the new Mylar.
Where to affix Mylar:
1mm
0mm
Protruded amount of Mylar
Before change: 1.8mm
After change: 2.9mm
Mylar
Sharp Electronics (UK) Ltd., Document Systems Support
5/5
2. Remove the current Mylar on Entrance Upper Guide of Punch UN, and then affix the new Mylar.
Where to affix Mylar:
1mm
0mm
Protruded amount of Mylar
Before change: 1.8mm
After change: 2.9mm
Mylar
Display