DOWNLOAD Sharp MX-C380P / MX-C400P / MX-B380P / MX-B382P / MX-B400P (serv.man6) Service Manual ↓ Size: 57.04 MB | Pages: 127 in PDF or view online for FREE

Model
MX-C380P MX-C400P MX-B380P MX-B382P MX-B400P (serv.man6)
Pages
127
Size
57.04 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Service Manual (Revised May 2016).
File
mx-c380p-mx-c400p-mx-b380p-mx-b382p-mx-b400p-sm6.pdf
Date

Sharp MX-C380P / MX-C400P / MX-B380P / MX-B382P / MX-B400P (serv.man6) Service Manual ▷ View online

MX-C400P/C380P, MX-B400P/B380P/B382P  SIMULATION  5 – 3
2) Use the up/down scroll keys to switch the menu pages.
c. Entering the set value and the adjustment value
1) Use [BACK] key to select the "MAIN" mode.
2) Select an adjustment mode and an adjustment item. (Select an
adjustment mode and an adjustment item with the scroll keys
and press [OK] key.)
(Example) Adjust the developing bias voltage
3) Use [BACK] key to select the "10KEY" mode.
4) Select a numeral with the right and left scroll keys and press
[OK] key.
For a number of two or more digits, repeat the above proce-
dures for the number of times equal to the number of digits.
(First enter the top digit, then enter the lower digits sequen-
tially.)
(Example) When setting the adjustment value to 450
Use the right/left scroll keys to select 4 and press [OK] key.
Use the right/left scroll keys to select 5 and press [OK] key.
Use the right/left scroll keys to select 0 and press [OK] key.
5)
After entering the adjustment value or the set value, press
OSA shortcut key to fix the adjustment value or the set value.
Select [EXECUTE] button and press [OK] key, and the adjust-
ment value or the set value is fixed and the simulation is exe-
cuted.
NOTE: Normally the set value is fixed by pressing OSA shortcut
key. In some kinds of simulations, however, the set value is
set by selecting [EXECUTE] button and pressing [OK] key.
(Example)
The following is the case where the adjustment value or the set
value is fixed by selecting [EXECUTE] button and press [OK] key.
d. Item selection by the item number
A target item on the simulation menu is selected by the number
which is assigned to the item.
Example of an load operation check
1)
Use [BACK] key to select the "10KEY" mode.
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
)(('287387&+(&.
7(67
03)6
03*6
(;(&87(
&
.(<
0$,1
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
˷̚˹
'96(77,1*$1'287387
˖0,''/(63((''9%B.
˖0,''/(63((''9%B&
˖0,''/(63((''9%B0
˖0,''/(63((''9%B<
0,''/(
/2:
(;(&87(
7(67
.(<
                        & 
0$,1
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
˷̚˹
'96(77,1*$1'287387
˖0,''/(63((''9%B.
˖0,''/(63((''9%B&
˖0,''/(63((''9%B0
˖0,''/(63((''9%B<
0,''/(
/2:
(;(&87(
7(67
.(<
       
                & 
0$,1
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
˷̚˹
'96(77,1*$1'287387
˖0,''/(63((''9%B.
˖0,''/(63((''9%B&
˖0,''/(63((''9%B0
˖0,''/(63((''9%B<
0,''/(
/2:
(;(&87(
7(67
.(<
         
              & 
0$,1
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
˷̚˹
'96(77,1*$1'287387
˖0,''/(63((''9%B.
˖0,''/(63((''9%B&
˖0,''/(63((''9%B0
˖0,''/(63((''9%B<
0,''/(
/2:
(;(&87(
7(67
.(<
                        & 
0$,1
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
)$;62)76:6(77,1*
7(67
6:12
'$7$
6:1R
(;(&87(
.(<
 
                      & 
0$,1
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
)(('287387&+(&.
7(67
3)0
)80
&3)&
/6866
320)
260
3&66
&38&
550
&3)0
785&
&/80
3205
:710
/6866
&/80
(;(&87(
&
.(<
0$,1
MX-C400P/C380P, MX-B400P/B380P/B382P  SIMULATION  5 – 4
2) Enter the number indicated on the left side of the target item.
Select the number of the target item number with the right/left
scroll keys and press [OK] key.
For a numeral of 2 digits, repeat the above procedure twice.
(First enter the upper digit, then enter the lower digit.)
The entered number of the target item is displayed on the left
under corner of the screen.
3)
Press OSA shortcut key to fix the target item.
4)
The selected target item is highlighted.
5)
With [EXECUTE] button selected, press [OK] key, and the sim-
ulation of the selected item is executed.
In the "10KEY" mode, however, this operation cannot be exe-
cuted.
There are several simulation menu pages. To switch the simulation
menu pages, use the up/down scroll keys.
2. List of simulation codes
NOTE: In this simulation, some functions of "COPY" and "FAX" which are not provided in this model may be displayed.
They are only displayed by the program, but they do not work.
This manual does not describe the contents of SIM66-1/2/3/61 (items related to FAX).
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
)(('287387&+(&.
7(67
3)0
)80
&3)&
/6866
320)
260
3&66
&38&
550
&3)0
785&
&/80
3205
:710
/6866
&/80
(;(&87(
&
.(<
0$,1
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
)(('287387&+(&.
7(67
3)0
)80
&3)&
/6866
320)
260
3&66
&38&
550
&3)0
785&
&/80
3205
:710
/6866
&/80
(;(&87(
&
.(<
0$,1
Main
Sub
Functions
Section
3
2
Used to check the operations of the sensors and the detectors in the finisher and the control circuit.
Finisher
3
Used to check the operation of the load in the finisher and the control circuit.
Finisher
10
Used to adjust the finisher.
Finisher
4
2
Used to check the operations of the sensors and detectors in the paper feed tray, and the control circuit of 
those.
Paper feed tray (Option)
3
Used to check the operations of the loads in the paper feed tray, and the control circuit of those.
Paper feed tray
5
Used to check the operations of the paper feed tray unit paper transport clutch (DTRC).
Paper feed tray unit
5
1
Used to check the operation of the display, LCD in the operation panel, and control circuit.
Operation panel
2
Used to check the operation of the heater lamp and the control circuit.
Fusing
4
Used to check the operation of the discharge lamp and the control circuit.
Process
6
1
Used to check the operations of the load in the paper transport system (clutches and solenoids) and the 
control circuits.
Paper transport/Paper exit section
2
Used to check the operations of each fan motor and its control circuit.
Others
3
Used to check the operations of the primary transfer unit and the control circuit.
Process (Transfer)
6
Used to check the operation of the fusing separation.
Fusing
51
Used to forcibly cut down the initial fuse of the developer unit and the fusing unit.
Developing, fusing unit
7
1
Used to set the operating conditions of aging.
Others
6
Used to set the operating intermittent aging cycle.
8
Used to display the warm-up time.
8
1
Used to check and adjust the operations of the developing voltage in each print mode and the control 
circuit. * When the middle speed is adjusted, the low speed are also adjusted simultaneously.
Process (Developing)
2
Used to check and adjust the operation of the main charger grid voltage in each printer mode and the 
control circuit. * When the middle speed is adjusted, the low speed are also adjusted simultaneously.
Process (Charging)
6
Used to check and adjust the operation of the transfer voltage and the control circuit.
Process (Transport)
9
2
Used to check the operations of the sensors and detectors in the paper reverse section (duplex section) 
and its control circuit.
Duplex
3
Used to check the operations of the load in the switchback section (duplex section) and its control circuit.
Duplex
10
1
Used to check the operations of the toner supply mechanism (toner motor) and the related circuit.
Process (Developing)
13
-
Used to cancel the self-diag "U1" trouble.
14
-
Used to cancel the self-diag H3, H4, H5 troubles.
16
-
Used to cancel the self-diag "U2" trouble.
MFP PWB / PCU PWB
17
-
Used to cancel the self-diag "PF" trouble.
21
1
Used to set the maintenance cycle.
MX-C400P/C380P, MX-B400P/B380P/B382P  SIMULATION  5 – 5
22
1
Used to check the print count value in each section and each operation mode. (Used to check the 
maintenance timing.)
2
Used to check the total numbers of mis-feed and troubles. (When the number of total jam is considerably 
great, it is judged as necessary for repair.)
3
Used to check mis-feed positions and the mis-feed count of each position. * Presumption of the faulty point 
by this data is possible.
4
Used to check the trouble (self diag) history.
5
Used to check the ROM version of each unit (section).
Firmware
6
Used to output various adjustment/setting data (simulations, FAX soft switch counter), the firmware 
version, the counter list, the process control data, and SIM50-24 data.
8
Used to check the number of operations (counter value) of the finisher, the RSPF, and the scan (reading) 
unit.
9
Used to check the number of use (print quantity) of each paper feed section.
Paper feed, ADU
10
Used to check the system configuration (option, internal hardware).
13
Used to check the operating time of the process section (OPC drum, DV unit, toner cartridge).
Process
90
Used to output the various set data lists.
23
2
Used to output the trouble history list of paper jam and mis-feed. (If the number of troubles of mis-feed is 
considerably great, the judgment is made that repair is required.)
80
Used to check the operation of paper feed and paper transport in the paper feed section and the paper 
transport section. Used to output the list of the operation status of the sensor and the detectors in the 
paper feed section and the paper transport section.
Paper feed, Paper transport
24
1
Used to clear the jam counter, and the trouble counter. (After completion of maintenance, clear the 
counters.)
2
Used to clear the number of use (the number of prints) of each paper feed section.
3
Used to clear the finisher counter.
4
Used to clear the maintenance counter, the printer counters of the transport unit and the fusing unit. (After 
completion of maintenance, clear the counters.)
5
Used to clear the developer counter. (After replacement of developer, clear the counter.)
7
Used to clear the OPC drum counter. (After replacement of the OPC drum, clear the counter.)
9
Used clear the printer mode print counter and the self print mode print counter.
30
Used to initialize the administrator password.
31
Used to initialize the service mode password.
34
Used to initialize the set items of SIM26-32.
25
1
Used to check the operations of the developing section.
Process (Developing section)
2
Used to make the initial setting of toner density when replacing developer. (Automatic adjustment)
Image process (Photo-conductor/
Developing/Transfer/Cleaning)
26
2
Used to set the paper weight type.
Paper feed
6
Used to set the specifications (paper, fixed magnification ratio, etc.) of the destination.
18
Used to set Disable/Enable of the toner save mode operation. (For the Japan and the UK versions.)
30
Used to set the operation mode corresponding to the CE mark (Europe safety standards). (For slow start 
to drive the fusing heater lamp)
32
Used to set display or non-display of the system setting menu.
35
Used to set the display mode of SIM 22-4 trouble history when a same trouble occurred repeatedly. There 
are two display modes: display as one trouble and display as several series of troubles.
38
Used to set Continue/Stop of print when the maintenance life is reached.
50
Used to set functions.
52
Used to set whether non-printed paper (insertion paper, cover paper) is counted up or not.
55
Used to set Enable/Disable of the automatic color calibration (automatic color balance adjustment) when 
replacing a consumable part. (In this simulation, the menu is displayed but it does not work.)
65
Used to set the staple process restriction.
69
Used to set the operating conditions for toner near end.
74
Used to set the OSA trial mode.
78
Used to set the password of the remote operation panel.
27
5
Used to set the machine tag No. (This function allows the host computer to check the machine tag No.) 
(FSS function)
Communication (RIC/MODEM)
9
Used to set the paper transport time recording YES/NO threshold value. (FSS function)
10
Used to clear the trouble prediction history information. (FSS function)
11
Used to check the serial communication retry number and the scanner gain adjustment retry number 
history. (FSS function)
12
Used to check the high-density, halftone process control and the automatic registration adjustment error 
history. (FSS Function)
13
Used to check the history of paper transport time between sensors. (FSS function)
30
1
Used to check the operations of the sensors and the detectors in other than the paper feed section and the 
control circuits.
2
Used to check the operations of the sensors and the detectors in the paper feed section and the control 
circuits.
40
2
Manual paper feed tray paper width sensor adjustment.
Paper feed
7
Used to set the adjustment value of the manual paper feed tray paper width sensor.
Paper feed
Main
Sub
Functions
Section
MX-C400P/C380P, MX-B400P/B380P/B382P  SIMULATION  5 – 6
43
1
Used to set the fusing reference temperature of each operation mode.
4
Used to set the fusing temperature 2 in each mode. (Continued from SIM 43-1.)
20
Used to set the environmental correction under low temperature and low humidity (L/L) for the fusing 
temperature setting (SIM 43-1) in each paper mode.
21
Used to set the environment correction under high temperature and high humidity (H/H) for the fusing 
temperature setting (SIM 43-1) in each paper mode.
22
Used to set the environment correction under low temperature and low humidity (L/L) for the fusing 
temperature setting (SIM 43-4) in each paper mode.
23
Used to set the environment correction under high temperature and high humidity (H/H) for the fusing 
temperature setting (SIM 43-4) in each paper mode.
24
Used to set the correction of the temperature adjustment value of SIM 43-1 and 43-4.
44
1
Used to set each correction operation function in the image forming (process) section.
Image process (Photo-conductor/
Developing/Transfer/Cleaning)
2
Used to adjust the sensitivity of the image density sensor (registration sensor).
Process
4
Used to set the conditions of the high density process control operation.
Process
6
Used to execute the high density process control forcibly.
Process
9
Used to display the result data of the high density process control operation.
Image process (Photo-conductor/
Developing/Transfer/Cleaning)
12
Used to display the operation data of the high density process control and the image density sensor 
(registration sensor).
Image process (Photo-conductor/
Developing)
13
Used to perform the color image sensor (image registration sensor F) calibration.
14
Used to display the output level of the temperature and humidity sensor.
Process (OPC drum, 
development)/Fusing/LSU
16
Used to display the toner density control data.
Developing system
21
Used to set the halftone process control target.
Process
22
Used to display the toner patch density level in the halftone process control operation.
Process
24
Used to display the correction target and the correction level in the halftone process control operation.
Process
25
Used to set the calculating conditions of the correction value for the halftone process control.
Process
26
Used to execute the halftone process control compulsorily.
Process
27
Used to clear the correction data of the halftone process control.
Process
28
Used to set the process control execution conditions.
Process
29
Used to set the operating conditions of the process control during a job.
Process
31
Used to adjust the OPC drum phase. (Manual adjustment) (MX-C400P/C380P)
Process
37
Used to set the development bias correction level in the continuous printing operation.
43
Used to display the identification information of the developing unit.
Developing system
61
Used to set the calibration data of the color image sensor (image registration sensor F).
46
21
Copy color balance adjustment (Manual adjustment)
48
6
Used to adjust the rotation speed of each motor.
49
1
Used to perform the firmware update.
3
Used to update the operation manual in the HDD.
50
1
Print image position, image loss adjustment
5
Used to adjust the print lead edge image position. (PRINTER MODE)
10
Used to adjust the black print image magnification ratio and the off-center position. (The adjustment is 
made separately for each paper feed section.)
20
Image registration adjustment (Manual adjustment)
22
Used to adjust the image registration. (Main scan direction, sub scan direction) (Auto adjustment)/OPC 
drum phase adjustment (Auto adjustment)
24
Used to display the detail data of SIM 44-2, 50-20 and 22.
51
1
Used to adjust the ON/OFF timing of the secondary transport voltage.
2
Used to adjust the contact pressure (deflection amount) on paper by the resist roller. (This adjustment is 
performed when there is a considerable variation in the print image position on the paper or when paper 
jams frequently occur.)
55
1
Used to set the specifications of the engine control operations. (SOFT SW)
3
Used to set the specifications of the controller operation. (SOFT SW)
56
1
Used to transport data between HDD - MFP PWB SRAM/EEPROM. (Used to repair the PWB.)
2
Used to backup the data in the EEPROM. SRAM, and HDD to the USB memory. (Corresponding to the 
device cloning and the storage backup.)
3
Used to backup the print hold data (document filling data) to the USB memory.
4
Used to backup the JOB log data to the USB memory.
60
1
Used to check the operations (read/write) of the MFP PWB memory.
2
Used to set the MFP PWB on-board SDRAM.
61
1
Used to check the LSU polygon motor rotation and laser detection.
LSU
3
Used to set the laser power 
4
Used to print the print image skew adjustment pattern. (LSU unit)
Main
Sub
Functions
Section
Page of 127
Display

Click on the first or last page to see other MX-C380P / MX-C400P / MX-B380P / MX-B382P / MX-B400P (serv.man6) service manuals if exist.