MX-B381/B401  SIMULATION  5 – 40
<Code descriptions>
Destination link item (When the destination setting is changed with
SIM26-6, the set value is changed linking with the destination.)
SW-A Setting value when plain paper is selected in the system set-
ting/device setting/fusing control setting.
SW-B Set value when heavy paper is selected in the system set-
ting/device setting/fusing control setting.
The set value displayed in this simulation differs depending on
plain paper or heavy paper which is selected in the system setting/
device setting/fusing control setting.
(Example) When plain paper is selected in the system setting/
device setting/fusing control setting, the value of SW-A is dis-
played. 
NOTE: When the destination is changed with SIM26-6 after chang-
ing this set value, the set values of the destination link
items are reset to the default. 
K
HL_LM HEAVY PAPER
Heavy paper TH_LM set value
30 - 200
140
L
HL_E HEAVY PAPER
Heavy paper TH_E set value
70 - 230
220
M
HL_UM OHP PAPER
OHP-TH_UM set value
70 - 230
180
N
HL_LM OHP PAPER
OHP-TH_LM set value
30 - 200
140
O
HL_E OHP PAPER
OHP-TH_E set value
70 - 230
220
P
HL_UM ENV PAPER
Envelope TH_UM set value
70 - 230
195
Q
HL_LM ENV PAPER
Envelope TH_LM set value
30 - 200
150
R
HL_E ENV PAPER
Envelope TH_E set value
70 - 230
215
S
HL_UM GLOSS PAPER
Glossy paper TH_UM set value
70 - 230
185
T
HL_LM GLOSS PAPER
Glossy paper TH_LM set value
30 - 200
140
U
HL_E GLOSS PAPER
Glossy paper TH_E set value
70 - 230
220
V
HL_UM E-STAR
Preheating TH_UM set value
30 - 200
165
W
HL_E E-STAR
Preheating TH_E set value
30 - 200
165
X
HL_UM PRE-JOB
Resetting from preheating TH_UM set value (Job Ready 
temperature)
30 - 200
170
Y
HL_LM E-STAR
Preheating TH_LM set value
30 - 200
115
Z
HL_UM WARMUP_120L
Warm-up TH_UM set value (when the fusing temperature is 
120
C or less)
70 - 230
175
190
185
190
185
190
AA
HL_LM WARMUP_120L
Warm-up TH_LM set value (when the fusing temperature is 
120
C or less)
30 - 200
120
135
130
135
130
135
AB
HL_E WARMUP_120L
Warm-up TH_E set value (when the fusing temperature is 
120
C or less)
70 - 230
225
AC
LO_WARMUP_TIME
Z - AB applying time 
(Time for shifting from the ready state to the normal control 
temperature (sec))
0 - 255
5
AD
HL_UM WARMUP_120H
Warm-up TH_UM set value (when the fusing temperature is 
120
C or above)
70 - 230
175
190
185
190
185
190
AE
HL_LM WARMUP_120H
Warm-up TH_LM set value (when the fusing temperature is 
120
C or above)
30 - 200
120
135
130
135
130
135
AF
HL_E WARMUP_120H
Warm-up TH_E set value (when the fusing temperature is 
120
C or above)
70 - 230
220
225
225
225
225
225
AG
HI_WARMUP_TIME
AD - AF applying time (Timer from completion of Ready)
0 - 255
5
AH
HI_WU_FM_ON_TMP
TH_E temperature for FM to start rotation in warming up 
(when the fusing temperature in warm-up is alpha 
C or 
above)
30 - 200
130
AI
HI_WU_END_TIME
Warm-up complete time (sec) (when the fusing temperature 
in warm-up is alpha 
C or above)
0 - 255
40
AJ
HI_WU_JOB_SET_TMP
TH_UM temperature to enable a job during warming up 
(when the fusing temperature in warm-up is alpha 
C or 
above)
70 - 230
170
185
180
185
170
185
AK
HI_WARMUP_BORDER
Threshold value applied to Sim43-1-AH - AJ
1 - 119
70
AL
LO_WU_JOB_SET_TMP
TH_UM temperature to enable a job during warming up 
(When the fusing temperature in warming up is alpha 
C or 
below.)
70 - 230
175
195
185
195
180
195
AM
JOBEND_FUMON_TIME
Fusing roller rotation time (sec) after completion of a job
0 - 255
5
Item/Display
Content
Setting 
range
Group A
Group B
Group C
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
TH_UM
Fusing upper thermistor (center)
TH_LM
Fusing lower thermistor
TH_E
Fusing thermistor (external heat roller)
HL_UM
Heater lamp upper
HL_LM
Heater lamp lower
HL_E
Heater lamp (external heat roller)
Group
Destination
Group A
Japan
China
AB_B
Group B
U.S.A.
Canada
Inch
Group C
Europe
U.K.
AUS
AB_A
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
)86(57(036(783)253$3(5
˷̚˹
˖+/B80ǂ5($'<
˖+/B/05($'<
˖+/B(5($'<
˖+/B803/$,13$3(5%:
˖+/B(3/$,13$3(5%:
˖+/B/03/$,13$3(5%:
˖:$5083)8021+/B(7
˖:$5083)802))
˖:$5083(1'7,0(
˖+/B80+($9<3$3(5
˖+/B/0+($9<3$3(5
˖+/B(+($9<3$3(5
2.
MX-B381/B401  SIMULATION  5 – 41
 
43-4
Purpose
Setting
Function (Purpose) Used to set the fusing temperature 2 in
each mode. (Continued from SIM 43-1.)
Section
Operation/Procedure
1)
Select an item to be set with [
] [] keys.
2)
Enter the set value with 10-key.
3)
Press [OK] key.
The set value in step 2) is saved.
NOTE: The set value is the reference value, and it may differ from
the actual fusing temperature depending on the operating
conditions.
<Code descriptions>
 
43-20
Purpose
Adjustment/Setup
Function (Purpose) Used to set the environmental correction
under low temperature and low humidity (L/
L) for the fusing temperature setting (SIM
43-1) in each paper mode.
Section
Operation/Procedure
1)
Select an item to be set with [
] [] keys.
2)
Enter the set value with 10-key.
3)
Press [OK] key.
The set value in step 2) is saved.
Correction value: -49 - +49, 1 Count = 1
C Change
Item/Display
Content
Setting 
range
Default value
Group A
Group B
Group C
SW-A
SW-B
SW-A
SW-B
SW-A
SW-B
A
HL_UM PLAIN PAPER BW DUP
Plain paper duplex TH_UM set value
70 - 230
175
190
185
190
185
190
B
HL_LM PLAIN PAPER BW DUP
Plain paper duplex TH_LM set value
30 - 200
110
125
120
125
120
125
C
HL_E PLAIN PAPER BW DUP
Plain paper duplex TH_E set value
70 - 230
220
220
220
220
220
220
D
PLAIN PAPER BW DUP APP CNT
Plain paper duplex fusing temperature application 
start image screen number
0  -  60
0
0
0
0
0
0
E
HL_UM HEAVY PAPER BW DUP
Heavy paper duplex TH_UM set value
70 - 230
185
F
HL_LM HEAVY PAPER BW DUP
Heavy paper duplex TH_LM set value
30 - 200
120
G
HL_E HEAVY PAPER BW DUP
Heavy paper duplex TH_E set value
70 - 230
220
H
HEAVY PAPER BW DUP APP CNT
Heavy paper duplex fusing temperature application 
start image screen number
0 - 60
1
TH_UM
Fusing upper thermistor (center)
TH_LM
Fusing lower thermistor
TH_E
Fusing thermistor (external heat roller)
HL_UM
Heater lamp upper
HL_LM
Heater lamp lower
HL_E
Heater lamp (external heat roller)
Group
Destination
Group A
Japan
China
AB_B
Group B
U.S.A.
Canada
Inch
Group C
Europe
U.K.
AUS
AB_A
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
)86(57(036(783)253$3(5
˷̚˹
˖+/B80ǂ3/$,13$3(5%:'83
˖+/B/0ǂ3/$,13$3(5%:'83
˖+/B(3/$,13$3(5%:'83
˖3/$,13$3(5%:'83$33&17
˖+/B/0+($9<3$3(5%:'83
˖+/B80+($9<3$3(5%:'83
˖+/B(+($9<3$3(5%:'83
˖+($9<3$3(5%:'83$33&17
2.
Correction value
-49
-25
-5
0
5
25
49
Input value
1
25
45
50
55
75
99
Item/Display
Content
Setting 
range
Group 
A
Group 
B
Group 
C
A
HL_UM READY LL
Ready standby TH_UM set value
1 - 99
55
55
55
B
HL_LM READY LL
Ready standby TH_LM set value
1 - 99
55
55
55
C
HL_E READY LL
Ready standby TH_E set value
1 - 99
55
55
55
D
HL_UM PLAIN PAPER BW LL
Plain paper TH_UM set value
1 - 99
55
55
55
E
HL_LM PLAIN PAPER BW LL
Plain paper TH_LM set value
1 - 99
55
55
55
F
HL_E PLAIN PAPER BW LL
Plain paper TH_E set value
1 - 99
55
55
55
G
WARMUP FUMON HL_E T LL
Fusing motor pre-rotation start TH_E set value
1 - 99
45
H
WARMUP FUMOFF LL
Fusing motor pre-rotation end time TH_LM set value
1 - 99
50
MX-B381/B401  SIMULATION  5 – 42
*1: 1 Count = 1sec Change
<Code descriptions>
 
43-21
Purpose
Adjustment/Setup
Function (Purpose) Used to set the environment correction
under high temperature and high humidity
(H/H) for the fusing temperature setting
(SIM 43-1) in each paper mode.
Section
Operation/Procedure
1)
Select an item to be set with [
] [] keys.
2)
Enter the set value with 10-key.
3)
Press [OK] key.
The set value in step 2 is saved.
Correction value: -49 - +49, 1 Count = 1
C Change
(*1)
WARMUP END TIME LL
Warm-up complete time (warm-up time (sec))
1 - 99
80
J
HL_UM HEAVY PAPER LL
Heavy paper TH_UM set value
1 - 99
55
K
HL_LM HEAVY PAPER LL
Heavy paper TH_LM set value
1 - 99
55
L
HL_E HEAVY PAPER LL
Heavy paper TH_E set value
1 - 99
50
M
HL_UM OHP PAPER LL
OHP-TH_UM set value
1 - 99
55
N
HL_LM OHP PAPER LL
OHP-TH_LM set value
1 - 99
55
O
HL_E OHP PAPER LL
OHP-TH_E set value
1 - 99
50
P
HL_UM ENV PAPER LL
Envelope TH_UM set value
1 - 99
55
Q
HL_LM ENV PAPER LL
Envelope TH_LM set value
1 - 99
55
R
HL_E ENV PAPER LL
Envelope TH_E set value
1 - 99
50
S
HL_UM GLOSS PAPER LL
Glossy paper TH_UM set value
1 - 99
55
T
HL_LM GLOSS PAPER LL
Glossy paper TH_LM set value
1 - 99
55
U
HL_E GLOSS PAPER LL
Glossy paper TH_E set value
1 - 99
50
V
HL_UM E-STAR LL
Preheating TH_UM set value
1 - 99
55
W
HL_E E-STAR LL
Preheating TH_E set value
1 - 99
55
X
HL_UM PRE-JOB LL 
Resetting from preheating TH_UM set value (Job Ready temperature)
1 - 99
55
Y
HL_LM E-STAR LL
Preheating TH_LM set value
1 - 99
55
Z
HL_UM WARMUP_120L LL
Warm-up TH_UM set value (when the fusing temperature is 120
C or less)
1 - 99
55
AA
HL_LM WARMUP_120L LL
Warm-up TH_LM set value (when the fusing temperature is 120
C or less)
1 - 99
55
AB
HL_E WARMUP_120L LL
Warm-up TH_E set value (when the fusing temperature is 120
C or less)
1 - 99
50
AC
LO_WARMUP_TIME LL
Z - AB applying time (Time (sec) for shifting from the control temperature in warm-
up to the normal control temperature)
1 - 99
50
AD
HL_UM WARMUP_120H LL
Warm-up TH_UM set value (when the fusing temperature is 120
C or above)
1 - 99
55
AE
HL_LM WARMUP_120H LL
Warm-up TH_LM set value (when the fusing temperature is 120
C or above)
1 - 99
55
AF
HL_E WARMUP_120H LL
Warm-up TH_E set value (when the fusing temperature is 120
C or above)
1 - 99
50
AG
HI_WARMUP_TIME LL
AD - AF applying time (Timer from completion of Ready)
1 - 99
50
AH
HI_WU_FM_ON_TMP LL
Fusing roller rotation start TH_E (when the fusing temperature in warm-up is alpha 
C or above)
1 - 99
45
AI 
(*1)
HI_WU_END_TIME LL
Warm-up complete time (sec) (when the fusing temperature in warm-up is alpha 
C or above)
1 - 99
50
AJ
HI_WU_JOB_SET_TMP LL
Job Ready TH_UM temperature (when the fusing temperature in warm-up is 
alpha 
C or above)
1 - 99
55
AK
HI_WARMUP_BORDER LL
Threshold value applied to Sim43-1-AH - AJ
1 - 99
50
AL
LO_WU_JOB_SET_TMP LL
TH_UM temperature to enable a job during warming up 
(when the fusing temperature in warming up is alpha 
C or below.)
1 - 99
55
AM 
(*1)
JOBEND_FUMON_TIME LL
Fusing roller rotation time (sec) after completion of a job
1 - 99
50
Item/Display
Content
Setting 
range
Group 
A
Group 
B
Group 
C
TH_UM
Fusing upper thermistor (center)
TH_LM
Fusing lower thermistor
TH_E
Fusing thermistor (external heat roller)
HL_UM
Heater lamp upper
HL_LM
Heater lamp lower
HL_E
Heater lamp (external heat roller)
Group
Destination
Group A
Japan
China
AB_B
Group B
U.S.A.
Canada
Inch
Group C
Europe
U.K.
AUS
AB_A
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
)86(57(03$'-8670(17//
˷̚˹
˖+/B805($'<//
˖+/B/05($'<//
˖+/B(5($'<//
˖+/B803/$,1%://
˖+/B(3/$,1%://
˖+/B/03/$,1%://
˖:$5083)8021+/B(7//
˖:$5083)802))//
˖:$5083(1'7,0(//
˖+/B80+($9<3$3(5//
˖+/B/0+($9<3$3(5//
˖+/B(+($9<3$3(5//
2.
Correction value
-49
-25
-5
0
5
25
49
Input value
1
25
45
50
55
75
99
MX-B381/B401  SIMULATION  5 – 43
*1: 1 Count = 1sec Change
<Code descriptions>
Item/Display
Content
Setting 
range
Group 
A
Group 
B
Group 
C
A
HL_UM READY HH
Ready standby TH_UM set value
1 - 99
50
50
50
B
HL_LM READY HH
Ready standby TH_LM set value
1 - 99
50
50
50
C
HL_E READY HH
Ready standby TH_E set value
1 - 99
50
50
50
D
HL_UM PLAIN PAPER BW HH
Plain paper TH_UM set value
1 - 99
50
50
50
E
HL_LM PLAIN PAPER BW HH
Plain paper TH_LM set value
1 - 99
50
50
50
F
HL_E PLAIN PAPER BW HH
Plain paper TH_E set value
1 - 99
50
50
50
G
WARMUP FUMON HL_E T HH
Fusing motor pre-rotation start TH_E set value
1 - 99
50
H
WARMUP FUMOFF HH
Fusing motor pre-rotation end time TH_LM set value
1 - 99
50
(*1)
WARMUP END TIME HH
Warm-up complete time (warm-up time (sec))
1 - 99
50
J
HL_UM HEAVY PAPER HH
Heavy paper TH_UM set value
1 - 99
50
K
HL_LM HEAVY PAPER HH
Heavy paper TH_LM set value
1 - 99
50
L
HL_E HEAVY PAPER HH
Heavy paper TH_E set value
1 - 99
50
M
HL_UM OHP PAPER HH
OHP-TH_UM set value
1 - 99
50
N
HL_LM OHP PAPER HH
OHP-TH_LM set value
1 - 99
50
O
HL_E OHP PAPER HH
OHP-TH_E set value
1 - 99
50
P
HL_UM ENV PAPER HH
Envelope TH_UM set value
1 - 99
50
Q
HL_LM ENV PAPER HH
Envelope TH_LM set value
1 - 99
50
R
HL_E ENV PAPER HH
Envelope TH_E set value
1 - 99
50
S
HL_UM GLOSS PAPER HH
Glossy paper TH_UM set value
1 - 99
50
T
HL_LM GLOSS PAPER HH
Glossy paper TH_LM set value
1 - 99
50
U
HL_E GLOSS PAPER HH
Glossy paper TH_E set value
1 - 99
50
V
HL_UM E-STAR HH
Preheating TH_UM set value
1 - 99
50
W
HL_E E-STAR HH
Preheating TH_E set value
1 - 99
50
X
HL_UM PRE-JOB HH 
Resetting from preheating TH_UM set value (Job Ready temperature)
1 - 99
50
Y
HL_LM E-STAR HH
Preheating TH_LM set value
1 - 99
50
Z
HL_UM WARMUP_120L HH
Warm-up TH_UM set value (when the fusing temperature is 120
C or less)
1 - 99
50
AA
HL_LM WARMUP_120L HH
Warm-up TH_LM set value (when the fusing temperature is 120
C or less)
1 - 99
50
AB
HL_E WARMUP_120L HH
Warm-up TH_E set value (when the fusing temperature is 120
C or less)
1 - 99
50
AC 
(*1)
LO_WARMUP_TIME HH
Z - AB applying time (Time (sec) for shifting from the control temperature in 
warm-up to the normal control temperature)
1 - 99
50
AD
HL_UM WARMUP_120H HH
Warm-up TH_UM set value (when the fusing temperature is 120
C or above)
1 - 99
50
AE
HL_LM WARMUP_120H HH
Warm-up TH_LM set value (when the fusing temperature is 120
C or above)
1 - 99
50
AF
HL_E WARMUP_120H HH
Warm-up TH_E set value (when the fusing temperature is 120
C or above)
1 - 99
50
AG
HI_WARMUP_TIME HH
AD - AF applying time (Timer from completion of Ready)
1 - 99
50
AH
HI_WU_FM_ON_TMP HH
Fusing roller rotation start TH_E (when the fusing temperature in warm-up is 
alpha 
C or above)
1 - 99
50
AI 
(*1)
HI_WU_END_TIME HH
Warm-up complete time (sec) (when the fusing temperature in warm-up is alpha 
C or above)
1 - 99
50
AJ
HI_WU_JOB_SET_TMP HH
Job Ready TH_UM temperature (when the fusing temperature in warm-up is 
alpha 
C or above)
1 - 99
50
AK
HI_WARMUP_BORDER HH
Threshold value applied to Sim43-1-AH - AJ
1 - 99
50
AL
LO_WU_JOB_SET_TMP HH
TH_UM temperature to enable a job during warming up 
(When the fusing temperature in warming up is alpha 
C or below.)
1 - 99
50
AM 
(*1)
JOBEND_FUMON_TIME HH
Fusing roller rotation time (sec) after completion of a job
1 - 99
50
TH_UM
Fusing upper thermistor (center)
TH_LM
Fusing lower thermistor
TH_E
Fusing thermistor (external heat roller)
HL_UM
Heater lamp upper
HL_LM
Heater lamp lower
HL_E
Heater lamp (external heat roller)
Group
Destination
Group A
Japan
China
AB_B
Group B
U.S.A.
Canada
Inch
Group C
Europe
U.K.
AUS
AB_A
ǂǂǂ6,08/$7,21ǂǂ12
&/26(
7(67
)86(57(03$'-8670(17++
˷̚˹
˖+/B805($'<++
˖+/B/05($'<++
˖+/B(5($'<++
˖+/B803/$,13$3(5%:++
˖+/B(3/$,13$3(5%:++
˖+/B/03/$,13$3(5%:++
˖:$5083)8021+/B(7++
˖:$5083)802))++
˖:$5083(1'7,0(++
˖+/B80+($9<3$3(5++
˖+/B/0+($9<3$3(5++
˖+/B(+($9<3$3(5++
2.
Page of 127
Display

Click on the first or last page to see other MX-B381 / MX-B401 (serv.man7) service manuals if exist.