HDD Replacement Procedure 
SHARP
Document Solution Centre
29 
 
 
Most data that is stored on the HDD can be backed up and reinstalled following replacement or HDD 
failure. If the HDD is operating normally before replacement, backup the data and then reinstall the data 
onto the replacement HDD. 
 
The HDD contains the following data:- 
 
No. 
Data 
Backup Method 
Data Reinstall Method 
Reinstall  
Operator 
e-Manual 
Cannot be backed up 
Sim49-03 Service 
Address book 
Sim56-02 / Device cloning 
/ Storage backup 
Sim56-02 / Device cloning 
/ Storage backup 
Service 
Image Send registration 
data (Sender’s information, 
meta data, etc.) 
Sim56-02 / Device cloning 
/ Storage backup 
Sim56-02 / Device cloning 
/ Storage backup 
Service 
User authentication 
Account management 
Sim56-02 Sim56-02 
Service 
Japanese FEP dictionary 
Not available 
 
— 
Chinese FEP dictionary 
Not available 
 
— 
JOB LOG 
Perform via WEB PAGE 
 — 
JOB completion list 
Not available 
 
— 
New N/A (FSS) information 
Not available 
 
— 
10 
User font (Added) 
Not available 
Perform via WEB PAGE. 
Service or 
User 
11 
User macro 
Not available 
Perform via WEB PAGE 
12 
Document filing 
Perform via WEB PAGE or 
Sim56-03 
Perform via WEB PAGE 
13 
System setting data 
Sim56-02 / Device cloning 
/ Storage backup 
Sim56-02 / Device cloning 
/ Storage backup 
Service 
14 
Watermark 
Cannot be backed up 
Sim49-5 Service 
15 
User colour profile 
Not available 
Perform via WEB PAGE 
Service 
16 
Mirroring information 
(When the mirroring kit is 
installed, the mirroring 
information is written.) 
Not available 
Forcible rebuilding is 
performed. 
Service 
17 
Individual setting 
information for direct WEB 
browsing 
  
Service 
18 
Cookie file for  
OSA application 
  
Service 
19 
eOSA application file 
 
Reinstallation of 
application 
Service 
20 
User file saved in the SMB 
server (NAS) 
  
Service 
HDD Replacement Procedure 
 
30 
SHARP
Document Solution Centre
 
 
HDD Replacement Procedure 
 
1. Back up the HDD storage data before replacement:- 
 
x Use SIM56-02 or device cloning/storage backup function to backup the Address book, Image 
Send registration data and User authentication data to USB memory. 
 
x When using the MFP Web Page, back up the Document Filing data, Font, Macro and JOB LOG 
data to PC 
 
Note: Document Filing data can also be backed up using SIM56-03 
 
2. When there is FAX/Internet Fax received data present, use SIM66-62 to backup the image data to 
USB memory (PDF file), and then provide the PDF data to the user. (This data cannot be restored 
to the machine). 
 
3. Replace the HDD. 
 
4. Power on / Boot the MFP Device:- 
 
x For new HDD (from service parts) only, Formatting is automatically performed. 
 
x When using an HDD from another MFP Device, U2-05 trouble will be displayed. Use SIM16 to 
cancel U2-05 trouble and then format the HDD using SIM62-01. 
 
5. Clear the FAX/SCANNER image memory by executing SIM66-10:- 
 
This memory must be cleared for all models equipped with FAX/I-FAX and Network Scanner in order to 
keep compliance between the HDD data and the image related memory.  
 
6. Install the E-Manual Data onto the HDD using SIM49-03. 
 
7. Install Watermark data onto the HDD using SIM49-05:- 
 
U2-60 trouble will be displayed when no Watermark data is present . After installing the 
Watermark data, reboot the MFP and cancel U2-60 trouble by executing SIM16. 
 
8. Import the storage data backed up in Step 1. 
 
x Use SIM56-02 or device cloning/storage backup function to import the Address book, Image 
Send registration data and User authentication data etc. 
 
x Import the Document Filing data, User font and macro data - (The JOB LOG data can be backed 
up but cannot be imported). 
 
MX-EB12N Mirroring Kit 
SHARP
Document Solution Centre
31 
 
 
When the mirroring kit is installed, the two HDD units are named HDD1 (RAID/Mirroring Kit HDD) and HDD2  
(Standard Machine HDD). The status of the Mirroring Kit is displayed by one of the following UI Icons within the 
operation panel:- 
 
Mirroring Kit is installed. 
 
Mirroring Kit / HDD Trouble. 
 
Mirroring Kit / Rebuilding - Copying the whole contents of one HDD to the other HDD. 
 
 
Troubleshooting: 
 
Use SIM62-20 to check the HDD status, and refer to the following tables to confirm the relation between 
the HDD status and possible remedy :- 
 
 
Status & Trouble when             is displayed:-
 
 
SIM 62-20 
HDD2 
OK 
NONE 
REBUILDING 
ERROR 
TROUBLE 
HDD1 
OK 
– 
– 
NONE 
– 
– 
– 
– 
REBUILDING 
– 
– 
– 
– 
– 
ERROR 
– 
– 
– 
– 
TROUBLE 
– 
– 
– 
– 
 
 
Status & Trouble when E7-03 error message is displayed:- 
 
SIM 62-20 
HDD2 
OK 
NONE 
REBUILDING 
ERROR 
TROUBLE 
HDD1 
OK 
B or C 
NONE 
B or C 
REBUILDING 
ERROR 
TROUBLE 
D or E 
 
 
 
Cont’d 
 
MX-EB12N Mirroring Kit
 
 
32 
SHARP
Document Solution Centre
 
 
Troubleshooting: 
 
Case 
Trouble 
Cause 
Advice 
One HDD status 
is OK. 
 
One HDD status is 
NG 
Connection failure of the 
connectors and harness of the 
mirroring kit 
x Replace the HDD & perform the replacement 
procedure of the mirroring kit HDD. 
x Replace the mirroring kit and perform the 
replacement procedure of the mirroring kit 
HDD. 
When at least one 
HDD is OK. 
x Communication trouble 
through the SATA harness of 
HDD. 
x Trouble of HDD which 
indicates the status other than 
OK. 
x Broken data in HDD. 
x RAID PWB trouble. 
x Replace the cable. Remove and connect. 
x Replace the HDD which indicates other than 
OK and perform the replacement procedure 
of the mirroring kit HDD or standard machine 
HDD. 
x Replace both of the HDD of the mirroring kit 
and that of the machine. Perform the 
replacement procedure of the mirroring kit 
HDD and standard machine HDD. 
When at least one 
HDD is NONE. 
x Communication trouble 
through the SATA harness of 
HDD. 
x Connection failure between 
the mirroring kit and the HDD. 
x HDD trouble. 
x HDD SATA harness & 
connector trouble. 
x RAID PWB trouble. 
x Replace the cable. Remove and connect. 
x Check connection between the mirroring kit 
and the HDD. 
x Replace the HDD which indicates NONE. 
Perform the replacement procedure of the 
mirroring kit HDD or standard machine HDD. 
x Replace the mirroring kit. Perform the 
replacement procedure of the mirroring kit 
HDD or standard machine HDD. 
x Replace both of the HDD of the mirroring kit 
and that of the machine. 
When in TROUBLE- 
TROUBLE. 
x RAID PWB trouble 
x (Both or one) HDD trouble 
x Replace the mirroring kit. Perform the 
replacement procedure of the mirroring kit 
HDD or standard machine HDD. 
x Replace both of the HDD of the mirroring kit 
and that of the machine. Perform the 
replacement procedure of the mirroring kit 
HDD and standard machine HDD. 
When in TROUBLE- 
TROUBLE. 
(Occurring when 
replacing the HDD) 
x The mirroring kit is composed 
of HDD's that have different 
mirroring information. (eg. A 
HDD which has been used in 
the mirroring kit of another 
machine is installed.) 
x Replace both of the HDD of the mirroring kit 
and that of the machine. Perform the 
replacement procedure of the mirroring kit 
HDD and standard machine HDD. 
Other than cases B, 
C, D, and E 
x RAID PWB trouble. 
x Both HDD’s trouble. 
x Replace the mirroring kit. Perform the 
replacement procedure of the mirroring kit 
HDD or standard machine HDD. 
x Replace both of the HDD of the mirroring kit 
and that of the machine. Perform the 
replacement procedure of the mirroring kit 
HDD and standard machine HDD. 