Sharp MX-4140N / MX-4141N / MX-5140N / MX-5141N (serv.man4) Handy Guide ▷ View online
HDD Replacement Procedure
SHARP
Document Solution Centre
29
Most data that is stored on the HDD can be backed up and reinstalled following replacement or HDD
failure. If the HDD is operating normally before replacement, backup the data and then reinstall the data
onto the replacement HDD.
failure. If the HDD is operating normally before replacement, backup the data and then reinstall the data
onto the replacement HDD.
The HDD contains the following data:-
No.
Data
Backup Method
Data Reinstall Method
Reinstall
Operator
1
e-Manual
Cannot be backed up
Sim49-03 Service
2
Address book
Sim56-02 / Device cloning
/ Storage backup
Sim56-02 / Device cloning
/ Storage backup
Service
3
Image Send registration
data (Sender’s information,
meta data, etc.)
Sim56-02 / Device cloning
/ Storage backup
Sim56-02 / Device cloning
/ Storage backup
Service
4
User authentication
Account management
Sim56-02 Sim56-02
Service
5
Japanese FEP dictionary
Not available
—
6
Chinese FEP dictionary
Not available
—
7
JOB LOG
Perform via WEB PAGE
—
8
JOB completion list
Not available
—
9
New N/A (FSS) information
Not available
—
10
User font (Added)
Not available
Perform via WEB PAGE.
Service or
User
11
User macro
Not available
Perform via WEB PAGE
12
Document filing
Perform via WEB PAGE or
Sim56-03
Perform via WEB PAGE
13
System setting data
Sim56-02 / Device cloning
/ Storage backup
Sim56-02 / Device cloning
/ Storage backup
Service
14
Watermark
Cannot be backed up
Sim49-5 Service
15
User colour profile
Not available
Perform via WEB PAGE
Service
16
Mirroring information
(When the mirroring kit is
installed, the mirroring
information is written.)
Not available
Forcible rebuilding is
performed.
Service
17
Individual setting
information for direct WEB
browsing
Service
18
Cookie file for
OSA application
Service
19
eOSA application file
Reinstallation of
application
Service
20
User file saved in the SMB
server (NAS)
Service
HDD Replacement Procedure
30
SHARP
Document Solution Centre
HDD Replacement Procedure
1. Back up the HDD storage data before replacement:-
x Use SIM56-02 or device cloning/storage backup function to backup the Address book, Image
Send registration data and User authentication data to USB memory.
x When using the MFP Web Page, back up the Document Filing data, Font, Macro and JOB LOG
data to PC
Note: Document Filing data can also be backed up using SIM56-03
2. When there is FAX/Internet Fax received data present, use SIM66-62 to backup the image data to
USB memory (PDF file), and then provide the PDF data to the user. (This data cannot be restored
to the machine).
to the machine).
3. Replace the HDD.
4. Power on / Boot the MFP Device:-
x For new HDD (from service parts) only, Formatting is automatically performed.
x When using an HDD from another MFP Device, U2-05 trouble will be displayed. Use SIM16 to
cancel U2-05 trouble and then format the HDD using SIM62-01.
5. Clear the FAX/SCANNER image memory by executing SIM66-10:-
This memory must be cleared for all models equipped with FAX/I-FAX and Network Scanner in order to
keep compliance between the HDD data and the image related memory.
keep compliance between the HDD data and the image related memory.
6. Install the E-Manual Data onto the HDD using SIM49-03.
7. Install Watermark data onto the HDD using SIM49-05:-
U2-60 trouble will be displayed when no Watermark data is present . After installing the
Watermark data, reboot the MFP and cancel U2-60 trouble by executing SIM16.
Watermark data, reboot the MFP and cancel U2-60 trouble by executing SIM16.
8. Import the storage data backed up in Step 1.
x Use SIM56-02 or device cloning/storage backup function to import the Address book, Image
Send registration data and User authentication data etc.
x Import the Document Filing data, User font and macro data - (The JOB LOG data can be backed
up but cannot be imported).
MX-EB12N Mirroring Kit
SHARP
Document Solution Centre
31
When the mirroring kit is installed, the two HDD units are named HDD1 (RAID/Mirroring Kit HDD) and HDD2
(Standard Machine HDD). The status of the Mirroring Kit is displayed by one of the following UI Icons within the
operation panel:-
(Standard Machine HDD). The status of the Mirroring Kit is displayed by one of the following UI Icons within the
operation panel:-
Mirroring Kit is installed.
Mirroring Kit / HDD Trouble.
Mirroring Kit / Rebuilding - Copying the whole contents of one HDD to the other HDD.
Troubleshooting:
Use SIM62-20 to check the HDD status, and refer to the following tables to confirm the relation between
the HDD status and possible remedy :-
Status & Trouble when is displayed:-
the HDD status and possible remedy :-
Status & Trouble when is displayed:-
SIM 62-20
HDD2
OK
NONE
REBUILDING
ERROR
TROUBLE
HDD1
OK
–
A
–
A
A
NONE
A
–
–
–
–
REBUILDING
–
–
–
–
–
ERROR
A
–
–
–
–
TROUBLE
A
–
–
–
–
Status & Trouble when E7-03 error message is displayed:-
SIM 62-20
HDD2
OK
NONE
REBUILDING
ERROR
TROUBLE
HDD1
OK
B
B or C
B
B
B
NONE
B or C
C
C
C
C
REBUILDING
B
C
F
F
F
ERROR
B
C
F
F
F
TROUBLE
B
C
F
F
D or E
Cont’d
MX-EB12N Mirroring Kit
32
SHARP
Document Solution Centre
Troubleshooting:
Case
Trouble
Cause
Advice
A
One HDD status
is OK.
One HDD status is
NG
Connection failure of the
connectors and harness of the
mirroring kit
x Replace the HDD & perform the replacement
procedure of the mirroring kit HDD.
x Replace the mirroring kit and perform the
replacement procedure of the mirroring kit
HDD.
HDD.
B
When at least one
HDD is OK.
x Communication trouble
through the SATA harness of
HDD.
HDD.
x Trouble of HDD which
indicates the status other than
OK.
OK.
x Broken data in HDD.
x RAID PWB trouble.
x RAID PWB trouble.
x Replace the cable. Remove and connect.
x Replace the HDD which indicates other than
x Replace the HDD which indicates other than
OK and perform the replacement procedure
of the mirroring kit HDD or standard machine
HDD.
of the mirroring kit HDD or standard machine
HDD.
x Replace both of the HDD of the mirroring kit
and that of the machine. Perform the
replacement procedure of the mirroring kit
HDD and standard machine HDD.
replacement procedure of the mirroring kit
HDD and standard machine HDD.
C
When at least one
HDD is NONE.
x Communication trouble
through the SATA harness of
HDD.
HDD.
x Connection failure between
the mirroring kit and the HDD.
x HDD trouble.
x HDD SATA harness &
x HDD SATA harness &
connector trouble.
x RAID PWB trouble.
x Replace the cable. Remove and connect.
x Check connection between the mirroring kit
x Check connection between the mirroring kit
and the HDD.
x Replace the HDD which indicates NONE.
Perform the replacement procedure of the
mirroring kit HDD or standard machine HDD.
mirroring kit HDD or standard machine HDD.
x Replace the mirroring kit. Perform the
replacement procedure of the mirroring kit
HDD or standard machine HDD.
HDD or standard machine HDD.
x Replace both of the HDD of the mirroring kit
and that of the machine.
D
When in TROUBLE-
TROUBLE.
x RAID PWB trouble
x (Both or one) HDD trouble
x (Both or one) HDD trouble
x Replace the mirroring kit. Perform the
replacement procedure of the mirroring kit
HDD or standard machine HDD.
HDD or standard machine HDD.
x Replace both of the HDD of the mirroring kit
and that of the machine. Perform the
replacement procedure of the mirroring kit
HDD and standard machine HDD.
replacement procedure of the mirroring kit
HDD and standard machine HDD.
E
When in TROUBLE-
TROUBLE.
(Occurring when
replacing the HDD)
x The mirroring kit is composed
of HDD's that have different
mirroring information. (eg. A
HDD which has been used in
the mirroring kit of another
machine is installed.)
mirroring information. (eg. A
HDD which has been used in
the mirroring kit of another
machine is installed.)
x Replace both of the HDD of the mirroring kit
and that of the machine. Perform the
replacement procedure of the mirroring kit
HDD and standard machine HDD.
replacement procedure of the mirroring kit
HDD and standard machine HDD.
F
Other than cases B,
C, D, and E
x RAID PWB trouble.
x Both HDD’s trouble.
x Both HDD’s trouble.
x Replace the mirroring kit. Perform the
replacement procedure of the mirroring kit
HDD or standard machine HDD.
HDD or standard machine HDD.
x Replace both of the HDD of the mirroring kit
and that of the machine. Perform the
replacement procedure of the mirroring kit
HDD and standard machine HDD.
replacement procedure of the mirroring kit
HDD and standard machine HDD.