DOWNLOAD Sharp MX-3050N / MX-3060N / MX-3070N / MX-3550N / MX-3560N / MX-3570N / MX-4050N / MX-4060N / MX-4070N (serv.man6) Service Manual ↓ Size: 104.48 MB | Pages: 127 in PDF or view online for FREE

Model
MX-3050N MX-3060N MX-3070N MX-3550N MX-3560N MX-3570N MX-4050N MX-4060N MX-4070N (serv.man6)
Pages
127
Size
104.48 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / NOTE Service Manual for models with the V suffix only.
File
mx-3050n-mx-3060n-mx-3070n-mx-3550n-mx-3560n-mx-35.pdf
Date

Sharp MX-3050N / MX-3060N / MX-3070N / MX-3550N / MX-3560N / MX-3570N / MX-4050N / MX-4060N / MX-4070N (serv.man6) Service Manual ▷ View online

MX-4070V  SIMULATION  6 – 2
4. List of simulation codes
A. List of easy mode
(1)
List of menu (Installation)
(2)
List of menu (Maintenance)
The first menu
The second 
menu
SIM 
num
ber
SIM Title
1
Adjustment
1 Process
46-74
Copy/printer gradation auto 
adjustment
50-22
Auto adjustment of 
registration & drum position
2 Positioning
50-10
Manual image position 
adjustment
3 Copy
46-21
Color copy gradation manual 
adjustment
4 Printer
67-25
Printer gradation manual 
adjustment
64-5
Printer self print (PCL)
5 Image 
Quality 
Adjustment
63-2
Shading execution
63-3
Scanner color balance auto 
adjustment
44-6
High density / engine halftone 
process control compulsory 
execution
44-26
Half tone density correct 
execution
46-74
Copy/printer gradation auto 
adjustment
2
Registration 
Settings
1 Function/ 
Option 
settings
26-1
Paper output system setup
26-2
Size setup
26-3
Auditor setup
26-50
Function setting
26-65
Finisher alarm mode setup 
(staple limit)
26-78
ROPE password setting
2 Counter 
mode
26-5
A3(11x17) countup
26-8
Banner size countup
26-52
A blank paper count mode 
setup
3 FAX/Image 
send 
settings
66-1
Image send software SW. 
setting
4 Toner 
setting
26-18
Toner save mode setup
26-69
Toner near end setting
5 FSS setting
27-2
FSS function setup (input)
27-4
FSS function setup
27-7
FSS function setup (function)
27-9
FSS function adjustment
27-14
FSS test mode setup
27-15
FSS connect status
27-16
FSS alert setting
27-17
FSS paper order alert setting
3
Data 
display
1 Counter 
display
22-1
Counter display
22-9
Paper feed counter display
22-13
Process cartridge display
2 System/ 
Version
22-5
ROM version data display
22-10
Machine system display
3 List printing
22-6
Data print mode
23-2
JAM/trouble data print mode
4 USB 
storage
56-99
Export all log data
4
Version 
upgrade
49-1
Firmware update
49-3
E-manual update
49-5
Water mark update
49-6
OCR data update
49-10
ACU update
5
Error 
release
13
U1 trouble cancellation
14
Trouble cancellation (other)
15
Paper feed trouble 
cancellation
16
U2 trouble cancellation
6
Ready for 
transport
6-90
Load move for shipment
10-3
Toner cartridge eject sensor 
check
10
History
1 Date list
Use 
SIM
The first menu
The second 
menu
SIM 
num
ber
SIM Title
1
Data 
display
1 Counter 
display
22-1
Counter display
22-8
Org./staple counter display
22-9
Paper feed counter display
22-13
Process cartridge display
2 JAM 
history data 
display
22-3
JAM history data display
22-12
SPF JAM history data display
3 System/ 
Version
22-5
ROM version data display
22-10
Machine system display
4 List printing
22-6
Data print mode
23-2
JAM/trouble data print mode
5 USB 
storage
56-99
Export all log data
2
Adjustment
1 Positioning
50-10
Manual image position 
adjustment
50-22
Auto adjustment of 
registration & drum position
2 Process
25-2
Automatic developer 
adjustment
44-2
Process control gain 
adjustment
46-74
Copy/printer gradation auto 
adjustment
3 Image 
Quality 
Adjustment
44-2
Process control gain 
adjustment
44-6
High density / engine halftone 
process control compulsory 
execution
44-26
Half tone density correct 
execution
61-13
Laser power correction data 
clear
61-11
Laser power auto correction
63-3
Scanner color balance auto 
adjustment
63-5
Standard scanner gamma 
setup
46-74
Copy/printer gradation auto 
adjustment
4 Cleaning
6-4
Charger cleaner check
5 Replacing 
developer
10-3
Toner cartridge eject sensor 
check
25-2
Automatic developer 
adjustment
3
Counter 
clear
24-1
JAM/trouble counter data 
clear
24-2
Paper feed counter clear
24-3
Org./output counter data clear
24-4
Maintenance counter clear
4
Registration 
Settings
21-1
Maintenance cycle setup
5
Version 
upgrade
49-1
Firmware update
49-3
E-manual update
49-5
Water mark update
49-6
OCR data update
49-10
ACU update
6
Error 
release
13
U1 trouble cancellation
14
Trouble cancellation (other)
15
Paper feed trouble 
cancellation
16
U2 trouble cancellation
The first menu
The second 
menu
SIM 
num
ber
SIM Title
MX-4070V  SIMULATION  6 – 3
(3)
List of menu (Adjustment and Settings)
B. List of classic mode
10
History
1 Date list
Use 
SIM
The first menu
The second 
menu
SIM 
num
ber
SIM Title
1
Adjustment
1 Positioning
50-1
Copy edge adjustment
50-5
Print edge adjustment
50-6
SPF edge adjustment
50-10
Manual image position 
adjustment
50-12
Original center offset setup
48-1
Ratio adjustment
48-5
Motor speed adjustment
50-22
Auto adjustment of 
registration & drum position
2 Image 
Quality 
Automatic 
Adjustment
50-22
Auto adjustment of 
registration & drum position
50-20
Registration adjustment
61-11
Laser power auto correction
46-74
Copy/printer gradation auto 
adjustment
3 Image 
Quality 
Adjustment
61-14
Laser power setting collective 
input
61-11
Laser power auto correction
61-13
Laser power correction data 
clear
46-74
Copy/printer gradation auto 
adjustment
46-54
Copy gradation auto 
adjustment (at dither)
46-52
Copy gradation data clear (at 
dither)
67-54
Printer gradation auto 
adjustment (at dither)
67-52
Printer gradation data clear 
(at dither)
2
Process
10-3
Toner cartridge eject sensor 
check
25-2
Automatic developer 
adjustment
44-2
Process control gain 
adjustment
46-74
Copy/printer gradation auto 
adjustment
3
Scanner/ 
SPF
41-1
PD sensor check
41-2
Document size photo-sensor 
setup
46-9
Exposure adjustment (SFP)
63-2
Shading execution
53-6
SPF tray adjustment
53-8
SPF scanning position 
adjustment
63-3
Scanner color balance auto 
adjustment
63-5
Standard scanner gamma 
setup
4
Paper 
feeding, 
Transport 
and paper 
ejection
1
40-2
Bypass tray adjustment
2
3-10
Finisher adjustment
The first menu
The second 
menu
SIM 
num
ber
SIM Title
5
Copy
46-21
Color copy gradation manual 
adjustment
44-21
Half tone process control 
standard value register setup
46-24
Copy gradation auto 
adjustment
46-54
Copy gradation auto 
adjustment (at dither)
63-7
Copy gradation auto 
adjustment target setup: 
service
63-8
Copy gradation auto 
adjustment target clear: 
service
63-11
Copy gradation auto 
adjustment target select
6
Printer
67-24
Printer gradation auto 
adjustment
67-25
Printer gradation manual 
adjustment
67-26
Printer gradation auto 
adjustment target select
67-27
Printer gradation auto 
adjustment target setup: 
service
67-28
Printer gradation auto 
adjustment target clear: 
service
7
Touch 
panel
65-1
Touch panel adjustment
8
Function/ 
Option 
settings
64-2
Self print (B/W) : service
9
Data 
display
1 Counter 
display
22-1
Counter display
22-9
Paper feed counter display
22-13
Process cartridge display
2 System/ 
Version
22-5
ROM version data display
22-10
Machine system display
3 List printing
22-6
Data print mode
23-2
JAM/trouble data print mode
4 USB 
storage
56-99
Export all log data
10
History
1 Date list
Use 
SIM
Sim 
No.
Easy Mode
Inst
al
lat
ion
Ma
inte
n
a
n
c
e
Ad
ju
stm
e
nt and
S
e
tti
ngs
1-1
Used to check the operation of the scanner 
(reading) unit and the control circuit
1-2
Used to check the sensors in the scanner 
(reading) section and the related circuit
1-5
Used to check the operation of the scanner 
(reading) unit and the control circuit
2-1
Used to check the operations of the automatic 
document feeder and the control circuit
2-2
Used to check the operations of the sensors 
and the detectors in the automatic document 
feeder section and the control circuit
2-3
Used to check the operations of the loads in 
the automatic document feeder and the 
control circuit
3-2
Used to check the operations of the sensors 
and the detectors in the finisher and the 
control circuit
3-3
Used to check the operation of the load in the 
finisher and the control circuit
The first menu
The second 
menu
SIM 
num
ber
SIM Title
MX-4070V  SIMULATION  6 – 4
3-10
Used to adjust the finisher
4
4-2
Used to check the operations of the sensors 
and detectors in the desk/large capacity tray 
(LCC) and the control circuit of those
4-3
Used to check the operations of the loads in 
the desk/large capacity tray (LCC) and the 
control circuit of those
4-5
Used to check the operations of the paper 
feed desk paper transport clutch (DTRC) and 
the LCC paper transport clutch (LTRC)
5-1
Used to check the operation of the display, 
LCD in the operation paper and the control 
circuit
5-2
Used to check the operation of the heater 
lamp and the control circuit
5-3
Used to check the operation of the scanner 
lamp and the control circuit
5-4
Used to check the operation of the discharge 
lamp and the control circuit
6-1
Used to check the operations of the load in 
the paper transport system (clutches and 
solenoids) and the control circuit
6-2
Used to check the operations of each fan 
motor and its control circuit
6-3
Used to check the operations of the transport 
unit and the control circuit
6-6
Used to perform fusing pressure release and 
applying and to check the operations of the 
control circuit
6-90
Used to reset the machine to the factory 
setting (The scanner is set to the lock enable 
position)
6
7-1
Used to set the operating conditions of aging
7-6
Used to set the operating intermittent aging 
cycle
7-8
Used to display the warm up time
7-9
Color setting in the color copy test mode 
(used to check the copy operation and the 
image quality for each color)
7-12
The document reading number of sheets (for 
aging operation)
8-1
Used to check and adjust the operations of 
the developping voltage in each print mode 
and the control circuit. *When the middle 
speed is adjusted the low speed are also 
adjusted simultaneously
8-2
Used to check and adjust the operation of the 
main charger grid voltage in each printer 
mode and the control circuit. *When the 
middle speed is adjusted the low speed are 
also adjusted simultaneously
8-6
Used to check and adjust the operation of the 
transport voltage and the control circuit
8-10
Main charger current output setting
9-2
Used to check the operations of the sensors 
and detectors in the paper reverse section 
(duplex section) and its control circuit
9-3
Used to check the operations of the load in 
the paper reverse section (duplex section) 
and its control circuit
10-1
Used to check the operations of the toner 
supply mechanism (toner motor) and the 
related circuit
10-3
Used to check the ejector position sensor
6
2-5
2
13
Used to cancel the self-diag U1 trouble
5
6
14
Used to cancel the self-diag H3, H4, H5 
troubles
5
6
15
Used to cancel the self-diag U6 trouble
5
6
16
Used to cancel the self-diag U2 trouble
5
6
Sim 
No.
Easy Mode
In
st
a
lla
ti
o
n
Main
te
nance
Adjus
tm
e
nt and
Set
ti
ngs
21-1
Used to set the maintenance cycle
4
22-1
Used to check the print count value in each 
section and each operation mode
3-1
1-1
9-1
22-2
Used to check the total number of misfeed 
and troubles
22-3
Used to check misfeed positions and the 
misfeed count of each position
1-2
22-4
Used to check the trouble (self diag) history
22-5
Used to check the ROM version of each unit
3-2
1-3
9-2
22-6
Used to output the setting/adjustment data, 
the firmware version and the counter list
3-3
1-4
9-3
22-8
Used to check the number of operations 
(counter value) of the finisher, the SPF and 
the scan (reading) unit
1-1
22-9
Used to check the number of use (print 
quantity) of each paper feed section
3-1
1-1
9-1
22-10
Used to check the system configuration 
(option, internal hardware)
3-2
1-3
9-2
22-11
Used to check the use frequency (send/
receive) of FAX
22-12
Used to check the SPF misfeed positions and 
the number os misfeed at each position
1-2
22-13
Used to check the operating time of the 
process section (OPC drum, DV unit, toner 
cartridge) and the fusing unit)
3-1
1-1
9-1
22-14
Used to display the use status of the toner 
cartridge
22-18
Used to display the user data delete history
22-19
Used to check the values of the counters 
related to the scan - image send
22-40
Used to display the error code list and the 
contents
22-41
Used to check JAM code information
22-42
Used to check the JAM/trouble data
22-43
JAM data details display
22-90
Used to output the various set data lists
23-2
Used to output the trouble history list of paper 
jam and misfeed
3-3
1-4
9-3
23-80
Used to check the operation of paper feed and 
paper transport in the paper feed section and 
the paper transport section. Used to output 
the list of the operation status of the sensor 
and detectors in the paper feed section and 
the paper transport section
23-81
Used to export paper feed time list
24-1
Used to clear the jam counter and the trouble 
counter
3
24-2
Used to clear the number of use (the number 
of prints) of each paper feed section
3
24-3
Used to clear the finisher, SPF and the scan 
(reading) unit counter
3
24-4
Used to clear the maintenance counter the 
printer counter of the transport unit and the 
fusing unit
3
24-5
Used to clear the developer counter
24-35
Used to clear the toner cartridge use status 
data
25-1
Used to check the operations of the 
developing section
25-2
Used to make the initial setting of toner 
density when replacing developer
2-2
-5
2
25-4
Used to display the operation data of the toner 
supply quantity
25-5
Used to display the toner density correction 
data
25-10
Developer/drum serial no setting
26-1
Used to set Yes/No of installation of the right 
paper exit tray
2-1
Sim 
No.
Easy Mode
In
st
a
lla
ti
o
n
Main
te
nance
Adjus
tm
e
nt and
Set
ti
ngs
MX-4070V  SIMULATION  6 – 5
26-2
Used to set the paper size of the large 
capacity tray (LCC)
2-1
26-3
Used to set the specifications of the auditor
2-1
26-5
Used to set the count mode of the total 
counter and the maintenance counter
2-2
26-6
Used to set the specifications of the 
destination
26-7
Used to set the machine ID
26-8
Used to set the counter mode (long scale)
2-2
26-10
Used to set the trial mode of the network 
scanner
26-18
Used to set Disable/Enable of the toner save 
mode operation
2-4
26-30
Used to set the operation mode 
corresponding to the CE mark
26-32
Used to set the specifications of the fusing 
cleaning operation
26-35
Used to set the display/mode of Sim 22-4 
trouble history when a same trouble occurred 
repeatedly. There are two display modes. 
Display as one trouble and display as several 
series of troubles
26-38
Used to set continue/stop of print when the 
maintenance life is reached
26-41
Used to set Enable/Disable of the 
magnification ratio automatic select function in 
the center binding mode
26-49
Used to set the print speed of postcard mode
26-50
Used to set functions
2-1
26-52
Used to set whether non-printed paper is 
counted up or not
2-2
26-65
Used to set the finisher alarm mode
2-1
26-66
Simulation password setting
26-69
Used to set the operating conditions for toner 
near end
2-4
26-73
Enlargement continuous shoot, A3 wide copy 
mode image loss adjustment
26-74
Used to set the OSA trial mode
26-78
Used to set the password of the remote 
operation panel
2-1
26-79
Used to set Yes/No of the pop-up display of 
security
26-85
Simulation function setting
27-2
Used to set the sender's registration number 
and the HOST server telephone number
2-5
27-4
Used to set the initial call and toner order auto 
send
2-5
27-5
Used to set the machine tag No.
27-6
Used to set of the manual service call
27-7
Used to set of the enable, alert callout
2-5
27-9
Used to set the paper transport time recording 
Yes/No threshold value and shading gain 
adjustment retry number
2-5
27-10
Used to clear the trouble prediction history 
information
27-11
Used to check the serial communication retry 
number and the scanner gain adjustment retry 
number history
27-12
Used to check the high density, halftone 
process control and the automatic registration 
adjustment error history
27-13
Used to check the history of paper transport 
time between sensors
27-14
Used to set the FSS function connection test 
mode
2-5
27-15
Used to display the FSS connection status
2-5
27-16
Used to set the FSS alert send
2-5
27-17
Used to set the FSS paper order alert
2-5
Sim 
No.
Easy Mode
In
st
a
lla
ti
o
n
Main
te
nance
Adjus
tm
e
nt and
Set
ti
ngs
30-1
Used to check the operations of the sensors 
and the detectors in other than the paper feed 
section and the control circuit
30-2
Used to check the operations of the sensors 
and the detectors in the paper feed section 
and the control circuit
30-30
Used to check the operation of the motion 
sensor
40-2
Manual paper feed tray paper width sensor 
adjustment
4
40-7
Used to set the adjustment value of the 
manual paper feed tray paper width sensor
41-1
Used to check the operations of the document 
size sensor and the control circuit
3
41-2
Used to adjust the document size sensor 
detection level
3
41-3
Used to check the operations of the document 
size sensor and the control circuit
43-1
Used to set the fusing temperature in each 
mode
43-2
Used to set the fusing operation and 
preheating
43-20
Used to set the environment correction under 
low temperature and low humidity (L/L) for the 
fusing temperature setting (Sim43-2) in each 
paper mode
43-21
Used to set the environment correction under 
high temperature and high humidity (H/H) for 
the fusing temperature setting (Sim43-2) in 
each paper mode
43-24
Fuser motion setup
43-35
Fusing nip operation check
44-1
Used to set each correction operation function 
in the image forming section
44-2
Used to adjust the sensitivity of the image 
density sensor
2-2
-3
2
44-4
Used to set the conditions of the high density 
process control operation
44-6
Used to execute the high density process 
control forcibly
1-5
2-3
44-9
Used to display the result data of the high 
density process control operation
44-12
Used to display the operation data of the high 
density process control and the image density 
sensor
44-14
Used to display the output level of the 
temperature and humidity sensor
44-15
Used to set the OPC drum idle rotation
44-17
Process refresh execution
44-21
Used to set the halftone process control target
5
44-22
Used to display the toner patch density level 
in the halftone process control operation
44-24
Used to display the correction target and the 
correction level in the halftone process control 
operation
44-25
Used to set the calculating conditions of the 
correction value for the halftone process 
control
44-26
Used to execute the halftone process control 
compulsory
1-5
2-3
44-27
Used to clear the correction data of the 
halftone process control
44-28
Used to set the process control execution 
conditions
44-29
Used to set the operating conditions of the 
process control during a job
44-31
Used to adjust the OPC drum phase (Manual 
adjustment)
Sim 
No.
Easy Mode
In
st
a
lla
ti
o
n
Main
te
nance
Adjus
tm
e
nt and
Set
ti
ngs
Page of 127
Display

Click on the first or last page to see other MX-3050N / MX-3060N / MX-3070N / MX-3550N / MX-3560N / MX-3570N / MX-4050N / MX-4060N / MX-4070N (serv.man6) service manuals if exist.