  MX-FR41U (DATA SECURITY KIT)  20 – 1
Service Manual
 
[20] MX-FR41U (DATA SECURITY KIT)
1.  Unpacking
A. Packed items check
2.  Installation
Before installing the data security kit, be sure to perform backup of
data stored in the memory (including HDD) of the main unit.
When the data security kit is installed, all the job data stored in the
memory (including HDD) of the main unit will be lost.
If the LINE indicator or the DATA indicator for the printer and image
transmission on the operation panel is lit or blinking, data that has
not been processed remains in the memory of the main unit (includ-
ing HDD). Output or transmit all the data to clear the data remaining
in the main unit and then start installation. 
Before installation, be sure to turn both the operation and main
power switches off and disconnect the power plug from the power
outlet. Make double sure that the data lamp on the operation panel
does not light up or blink when performing installation. 
A. Left cabinet and shield plate removal
1)
Remove the left cabinet.
2)
Remove the shield plate.
B.Program ROM attachment
1)
Attach the program ROM to the OPT ROM slot of the MFP
control PWB.
2)
Set the BOOT SW on the left upper side of the MFP control
PWB to OFF.
C. Shield plate and left cabinet attachment
1)
Attach the shield plate.
2)
Attach the left cabinet.
No.
Name
Quantity
1
Program  ROM
1
2
Product key sheet
1
3
User manual (CD-ROM)
1
4
Firmware program (USB memory)
1
2
1
1
2
2
1
1
1
2
2
1
2
1
: '13/Oct
1
1
1
  MX-FR41U (DATA SECURITY KIT)  20 – 2
D. Turn ON the power of the main unit
1)
Connect the power plug of the machine to the power outlet,
and turn ON the main power switch and the operation panel
power switch.
E. Firmware update procedures
(1) Entering the boot mode
1)
After power on, light the backlight and no message on the
screen.
2)
Few seconds later, the screen displays the following message.
3)
The machine enters the boot mode which indicates that there
is an error in the main program.
(2) Operations in the boot mode
When the machine is booted in the boot mode, the firmware ver-
sion check, the firmware install, and the version-up operation can
be performed.
NOTE: In the boot mode, the following keys are used for operation.
Note that the functions of the keys in the boot mode differ
from those in the normal mode.
a. Key functions and operations in the boot mode
b. Functions in the boot mode
The following two functions are available in the boot mode.
c. Selection of functions in the boot mode
There are two functions available in the boot mode. These modes
can be selected by pressing [MENU] key and [BACK] key.
(3) Firmware install and version-up procedures in the 
boot mode
1)
Boot the machine in the boot mode. When the Version Check
display is indicated, press [MENU] key, and the machine
enters the Firm Update mode.
2)
Insert the USB memory which includes the update firmware file
(SFU file) into the USB port of the machine, and press [OK]
key.
SFU file display
3)
Select the firmware file (SFU file) of the target.
Use [UP] key and [DOWN] key to select the target file.
When [OK] key is pressed with the directory name displayed,
the control can enter the lower level directory. (However, one-
step lower level)
When [BACK] key is pressed in the lower level directory, the
control can return to the upper level directory.
4)
Press [OK] key.
The selected firmware file (SFU) is read. (It takes about 1 min-
ute.)
Display of reading file data
Key name
Functions in the CN update mode
[OK] key
Executes the selected function or item.
[MENU] key
Selects a menu.
[BACK] key
Selects a menu.
(Serves as a cancel key in the execution check 
screen.)
[UP] key
Selects an item.
[DOWN] key
Selects an item.
Function
Content
Firmware 
version check 
function
Displays the firmware version of the ICU PWB, the 
SCU PWB, the PCU PWB, and the FAX PWB.
Firmware install 
(update) function
Installs (revises) the firmware by transmitting data 
from the PC which is connected to the ICU PWB, the 
SCU PWB, the PCU PWB, the FAX PWB, and other 
options with the USB memory or the USB cable.
 
-AIN
 
 
5PDATE
 
 
6ERSION
 
;$/7.=
;50=
;"!#+=
Version Check
IcM:UNUSUAL
Firm Update
    From USB Memory
 
[MENU] key
[BACK] key
[MENU] key
[BACK] key
 
&IRM
 
 
;$/7.=
;50=
;"!#+=
 
&IRM
 
 
&IRM
 
1
1
1
: '13/Oct
  MX-FR41U (DATA SECURITY KIT)  20 – 3
5) After completion of reading, the firmware is installed (updated).
(It takes about 5 - 6 minutes.)
Display of firmware install (Update) process
- The abbreviated name of the firmware which is currently
installed (updated) is displayed sequentially.
- The screen may flash instantaneously during the install
(update) process. This is a normal operation.
6)
Check the result of install (update) of the firmware.
Use [UP] key and [DOWN] key to check the results of install
(update) of all the firmware programs.
Display of firmware update results
OK: Update success
NG: Update failed
Not Update: The update process is not executed.
Cause of Update process not executed:
The option unit for the target firmware is not connected.
7)
Turn OFF the power to terminate the boot mode.
F. Enable setting of functions
1)
Enter the product key to enable the functions.
a)
Enter the system setting mode.
b)
The machine enters the product key input mode.
c)
Enter the product key.
d)
Press the registration key.
2)
After completion of the product key input, turn OFF the power
switch on the operation panel of the machine, and turn OFF
the main power switch.
3)
Turn ON the main power switch and the power switch on the
operation panel.
G. Confirmation of function enable
Execute SIM22-10 (Machine configuration display) to check to con-
firm that the set functions are enable.
 
&IRM
 
 
&IRM
5PDATE
 
&IRM
5PDATE
 
&IRM
5PDATE
1
: '13/Oct
1
MX-3640N  MX-EB11 (ENHANCED COMPRESSION KIT)  21 – 1
MX-3640N
Service Manual
 
[21] MX-EB11 (ENHANCED COMPRESSION KIT)
1.  Unpacking
A. Packed items check
*: Used only in Brazil and South Africa.
2.  Installation
Before  installation,  be  sure  to  turn  both the oper ation  and main 
power switches off and disconnect the power plug from the power 
outlet. Make double sure that the data lamp on the operation panel 
does not light up or blink when performing installation. 
A. Left cabinet and shield plate removal
1) Remove the left cabinet.
2) Remove the shield plate.
B. Scanner function expansion PWB installation
1) Connect the scanner function expansion PWB to the MFP con-
trol PWB, and fit it with the screw included in the package.
C. Shield plate and left cabinet installation
1) Install the shield plate.
2) Install the left cabinet.
D. Turn ON the power of the main unit
1) Connect  the powe r  plug of the machine to the powe r  outlet, 
and turn ON the  main power switch and the operation panel 
power switch.
No.
Name
Quantity
1
Scanner function expansion PWB
1
2
Screw
2
3*
Earth plate spring (Parts Code: MSPRP3009FCZZ)
1
1
2
3
2
1
1
2
2
1
1
2
1
1
2
2
1
2
Page of 126