DOWNLOAD Sharp MX-2640N / MX-2640NR / MX-2640FN / MX-3140N / MX-3140NR / MX-3140FN / MX-3640N / MX-3640NR / MX-3640FN (serv.man10) Service Manual ↓ Size: 42.66 MB | Pages: 126 in PDF or view online for FREE

Model
MX-2640N MX-2640NR MX-2640FN MX-3140N MX-3140NR MX-3140FN MX-3640N MX-3640NR MX-3640FN (serv.man10)
Pages
126
Size
42.66 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Installation Manual Revised June 2014.
File
mx-2640n-mx-2640nr-mx-2640fn-mx-3140n-mx-3140nr-mx.pdf
Date

Sharp MX-2640N / MX-2640NR / MX-2640FN / MX-3140N / MX-3140NR / MX-3140FN / MX-3640N / MX-3640NR / MX-3640FN (serv.man10) Service Manual ▷ View online

MX-3640N  MX-FX11 (FACSIMILE EXPANSION KIT)  18 – 1
MX-3640N
Service Manual
 
[18] MX-FX11 (FACSIMILE EXPANSION KIT)
1.  Unpacking
A. Packed items check
*: Brazil, South Africa only
2.  Installation
Before installation, be sure to turn both the operation and main
power switches off and disconnect the power plug from the power
outlet. Make double sure that the data lamp on the operation panel
does not light up or blink when performing installation.
A. FAX unit installation
1)
Remove the two screws on the rear cabinet of the main unit.
Attach the step screw (included in the package) to one of the
removed screw positions.
2)
Hang the Fax unit on the step screw. Fix the Fax unit with the
screws which were removed in the step 1).
B. Left cabinet and shield plate removal
1)
Remove the left cabinet.
2)
Remove the shield plate.
No.
Name
Quantity
1
Fax  unit
1
2
Line  cable
1
3
Ferrite core
2
4
Step screw (M3)
1
5
M3 screw
1(2)*
6
Binding band (Not used)
1*
7
Step screw (M4) (Not used)
1
8
Line cable
1
2
1
4
3
5
6
8
U.K
France
Germany
Australia
For other destinations
7
2
1
1
2
1
2
1
1
2
2
1
1
1
: '13/Oct
MX-3640N  MX-FX11 (FACSIMILE EXPANSION KIT)  18 – 2
C. I/F cable connection
1)
Connect the I/F cable to the MFP controller PWB, and fix the
binding band (and FG line (Taiwan, Brazil, South Africa)) with
the M3 screw included in the package.
Check to confirm that it is securely connected.
(Except Taiwan, Brazil, South Africa)
(Taiwan, Brazil, South Africa)
It is necessary to attach the ferrite core included in the main
unit.  
D. Shield plate and left cabinet attachment
1)
Attach the shield plate.
2)
Attach the left cabinet.
E. Turn ON the power of the main unit
1)
Connect the power plug of the machine to the power outlet,
and turn ON the main power switch and the operation panel
power switch.
F. Destination setting
1)
Enter the SIM26-6 mode.
2)
Check to confirm that the destination setting of the machine
matches the specifications of the FAX destination. If not, the
FAX may not function properly.
G. Clear the FAX related software switches
1)
Enter the SIM66-2 mode.
2)
Press DEST CODE button.
3)
Take a note of the corresponding destination code.
4)
Press BACK button to return to the code entry mode.
5)
Enter the destination code taken in procedure 3), and press
SET button.
6)
Press EXECUTE and YES buttons.
H. Line cable connection
1)
Connect the line cable on the line to the modular jack indicated
as “LINE.”
When connecting the line cable (to LINE or TEL), wind the line
cable two turns or one turn around the included ferrite core as
shown in the figure, and connect to the modular jack which is
marked with “LINE.”
After connection, perform the setting of “External telephone con-
nection” of the system setting (administrator).
2
1
Core
1
2
2
1
2
Except Taiwan,  Brazil, 
South Africa
Taiwan, Brazil, 
South Africa
About 
10 cm
2 turns
About 
10 cm
1 turn
1
1
: '13/Oct
MX-3640N  AR-SU1 (STAMP UNIT)  19 – 1
MX-3640N
Service Manual
 
[19] AR-SU1 (STAMP UNIT)
1.  Unpacking
A. Packed items check
*1: When replacing the stamp cartridge, Refer to “Stamp cartridge
replacement” in the “Operation Guide” (PDF document). The user
must be notified of that. (Do not refer  to “Stamp cartridge replace-
ment procedure” (package part).)
2.  Installation
Before  installation,  be  sure  to  turn  both the oper ation  and main
power switches off and disconnect the power plug from the power
outlet. Make double sure that the data lamp on the operation panel
does not light up or blink when performing installation. 
A. RSPF unit removal
1) Remove the harness guide and Disconnect the connector.
When disconnecting the connector, be careful of the  harness
of the scanner home position sensor.
2) Remove the RSPF unit from the main unit.
3) Put the RSPF unit on a stable table with the OC mat upside.
B. Stamp unit attachment
1) Open the OC mat.
2) Remove the sensor cover.
3) Remove the screw from the stamp unit mounting section. Use
the removed screw to attach the stamp unit together with the
earth wire, and connect the connector.
No.
Name
Quantity
1
Stamp unit
1
2
Stamp cartridge replacement procedure
 *1
1
3
Stamp cartridge
3
4
Installing screw
1
1
2
3
4
1
1
2
3
1
1
2
1
2
2
4
5
4
3
MX-3640N  AR-SU1 (STAMP UNIT)  19 – 2
4) Install the sensor cover.
5) Close the OC mat.
C. RSPF unit attachment
1) Attach the RSPF unit to the main unit.
2) Connect the connector and attach the harness guide.  
Place the harness of the scanner home position sensor at the
back  of  the  guide  and the  RSPF  harness.  Check to confirm
that  the co nnector  of  the  scanner  home position sen sor  is
securely connected.
D. Finish stamp cartridge attachment
1) Open the left cover, and open the document tray.
2) Attach the finish stamp cartridge.
E. Turn ON the power of the main unit
1) Connect  the powe r  plug of the machine to the powe r  outlet,
and turn ON the  main power switch and the operation panel
power switch.
F. Installation check
1) Use SIM22-10 to check  to confirm that the finish  stamp (AR-
SU1) is recognized.
1
3
3
2
2
2
1