AR-M550/M620  SIMULATION  8 - 85
2) Enter the number corresponding to the bit to be changed with 10-
key.
(Example) When the bit of 5 is to be changed, enter 5.
The set value of 1/0 is alternatively changed every time when the
target key is pressed.
3) After completion of setting of all the bits, press [START] key.
Operation/Procedure
1) Set the destination code with 10-key.
The codes other than the above are recognized as Japan.
2) Press [START] key.
3) The confirmation menu of YES/NO of clear is displayed. Select
one.
4) Press [START] key. 
The soft switch (except for the adjustment values) is cleared according
to the destination selected in procedure 1).
NOTE: When the FAX BOX is not installed, initialization including the
adjustment value is performed. (The adjustment value is stored
in the FAX BOX.)
Operation/Procedure
1) Enter the number corresponding to the memory to be checked with
10-key.
2) Press [START] key.
In the case of All, all memories are checked only once.
The error address or the data line is displayed individually.
When "repeat" is selected, the operation is repeated until the result is
"NG" or [CUSTOMSETTING" is pressed.
Press [START] key.
Press [CUSTOM SETTINGS] key or [START] key.
66-2
Purpose
Data clear
Function
(Purpose)
Used to clear the FAX soft switch function data and to 
set to the default. (Excluding the adjustment values.)
Section
FAX
Item
Data
Japan
0 0 0 0 0 0 0 0
Finland
0 0 1 1 1 1 0 0
U.S.A.
1 0 1 1 0 1 0 1
Norway
1 0 0 0 0 0 1 0
Australia
0 0 0 0 1 0 0 1
Denmark
0 0 1 1 0 0 0 1
U.K.
1 0 1 1 0 1 0 0
Netherlands
0 1 1 1 1 0 1 1
France
0 0 1 1 1 1 0 1
Italy
0 1 0 1 1 0 0 1
Germany
0 0 0 0 0 1 0 0
Switzerland
1 0 1 0 0 1 1 0
Sweden
1 0 1 0 0 1 0 1
Austria
0 0 0 0 1 0 1 0
Newzealand
0 1 1 1 1 1 1 0
Indonesia
0 1 0 1 0 1 0 0
China
0 0 1 0 0 1 1 0
Thailand
1 0 0 1 0 0 1
Singapore
1 0 0 1 1 1 0 0
Malaysia
0 1 1 0 1 1 0 0 
TW
1 1 1 1 1 1 1 0
India
0 1 0 1 0 0 1 1
Other1
1 1 1 1 1 1 0 1
Philippines
1 0 0 0 1 0 0 1
Other2
1 1 1 1 1 1 0 0
Hongkong
0 1 0 1 0 0 0 0
Ohter3
1 1 1 1 1 0 1 1
1
YES
FAX soft SW is cleared.
2
NO
Not cleared.
SIMULATION 66-1
FAX SOFT SW. SETTING. SELECT 2-120, AND PRESS START.
SIMULATION 66-1
FAX SOFT SW. SETTING. INPUT DATA No(1-8), AND PRESS
START.
     OFT SW-2:
1  2  3  4  5  6  7  8
Press [START] key.
66-3
Purpose
Operation test/Check
Function
(Purpose)
Used to  check the  operation of the FAX PWB memory 
(read/write). (This adjustment is required when the 
PWB is replaced with a new one.)
Section
FAX
Item
Data
Check connection wire list
NO CHECK
Not checked yet.
CHECKING
Checking
OK
Check complete OK
NG
Check complete NG
Target memory of check
MFP SRAM
SRAM
MFP FLASH
FLASH ROM
MFP OP.FLASH
MODEM EEPROM
MODEM SRAM (G/A)
MODEM SRAM
MODEM SDRAM
SIMULATION 66-2
FAX SOFT SW. CLEAR(WITHOUT ADJUSTMENT VALUE).
  INPUT COUNTRY CODE, AND PRESS START.
1  2  3  4  5  6  7  8
1
SIMULATION 66-2
FAX SOFT SW. CLEAR.
ARE YOU SURE?
  
JAPAN
1:YES
2:NO
AR-M550/M620  SIMULATION  8 - 86
When Check is "once," the display stops at the result display. When
[CUSTOM SETTINGS] key is pressed, the display returns to the initial
display.
Operation/Procedure
1) Enter the number corresponding to the output mode with 10-key.
2) Press [START] key.
The output is delivered at the max. send level.
When [CUSTOM SETTINGS] key is pressed during execution, execu-
tion is stopped. 
When a number is entered and [START] key is pressed during execu-
tion, the kind of signal can be changed.
Press [START] key.
Press [CUSTOM SETTINGS] key.
66-4
Purpose
Operation test/Check
Function
(Purpose)
Used to check the output operation of data signals in 
each data output mode of FAX. (Used to check the 
operation of MODEM. ) Send level: Max. (Only when 
FAX is installed)
Section
FAX
Item
Operation
1
NOSIGNAL
No signal
17
12.0 V33
12.0 V33
2
33.6 V34
26.4 V34
18
14.4 V17
14.4 V17
3
31.2 V34
31.2 V34
19
12.0 V17
12.0 V17
4
28.8 V34
28.8 V34
20
9.6 V17
9.6 V17
5
26.4 V34
26.4 V34
21
7.2 V17
7.2 V17
6
24.0 V34
24.0 V34
22
9.6 V29
9.6 V29
7
21.6 V34
21.6 V34
23
7.2 V29
7.2 V29
8
19.2 V34
19.2 V34
24
4.8 V27t
4.8 V27t
9
16.8 V34
16.8 V34
25
2.4 V27t
2.4 V27t
10
14.4 V34
14.4 V34
26
0.3 FLG
0.3 FLG
11
12.0 V34
12.0 V34
27
CED 2100
CED 2100
12
9.6 V34
9.6 V34
28
CNG 1100
CNG 1100
13
7.2 V34
7.2 V34
29
0.3 V21
0.3 V21
14
4.8 V34
4.8 V34
30
ANSam
ANSam
15
2.4 V34
2.4 V34
31
RINGER
RINGER
16
14.4 V33
14.4 V33
32
No RBT
No RBT
SIMULATION 66-3
FAX PWB MEMORY CHECK INPUT 1-13, AND PRESS START.
1.  All Memory Device Check (once)
2.  MFP SRAM(once)        3. MFP SRAM(repeat)
4.  MFP FLASH+ OP.FLASH(once)
5.  MFP FLASH+ OP>FLASH(repeat)
6.  MODEM EEPROM(once)    7. MODEM EEPROM(repeat)
8.  MODEM SRAM(G/A)(once) 9. MODEM SRAM(G/A)(repeat)
10. MODEM SRAM(once)     11. MODEM SRAM(repeat)
12. MODEM SDRAM(once)    13. MODEM SDRAM(repeat)
When "repeat" is selected and 
[CUSTOM SETTINGS] key is pressed.
SIMULATION 66-3
FAX PWB MEMORY CHECK
MFP SRAM: CHECKING
MFP FLASH: NO CHECK
MFP OP.FLASH: NO CHECK
MODEM EEPROM: NG:A0010000
MODEM SRAM(G/A):NO CHECK
MODEM SRAM: NG A11
MODEM SDRAM: OK
Press [START] key.
Enter 2 and press [START] key.
SIMULATION 66-4
SIGNAL OUTPUT CHECK.(LEVEL MAX)  SELECT 1-32, AND PRESS
START.
1.NOSIGNAL  2.33.6 V34  3.31.2 V34  4.28.8 V34
2.26.4 V34  6.24.0 V34  7.21.6 V34  8.19.2 V34
9.16.8 V34  10.14.4 V34 11.12.0 V34 12.9.6 V34
13.7.2 V34  14.4.8 V34  15.2.4 V34  16.14.4 V33
17.12.0 V33 18.14.4 V17 19.12.0 V17 20.9.6 V17
21.7.2 V17  22.9.6 V29  23.7.2 V29  24.4.8 V27t
25.2.4 V27t 26.0.3 FLG  27.CED 2100 28.CNG 1100
29.0.3 V21  30.ANSam    31.RINGER   32.No RBT
1
SIMULATION 66-4
SIGNAL OUTPUT CHECK.(LEVEL MAX)  SELECT 1-32, AND PRESS
START. EXECUTING···.
1.NOSIGNAL  2.33.6 V34  3.31.2 V34  4.28.8 V34
2.26.4 V34  6.24.0 V34  7.21.6 V34  8.19.2 V34
9.16.8 V34  10.14.4 V34 11.12.0 V34 12.9.6 V34
13.7.2 V34  14.4.8 V34  15.2.4 V34  16.14.4 V33
17.12.0 V33 18.14.4 V17 19.12.0 V17 20.9.6 V17
21.7.2 V17  22.9.6 V29  23.7.2 V29  24.4.8 V27t
25.2.4 V27t 26.0.3 FLG  27.CED 2100 28.CNG 1100
29.0.3 V21  30.ANSam    31.RINGER   32.No RBT
1
SIMULATION 66-4
SIGNAL OUTPUT CHECK.(LEVEL MAX)  SELECT 1-32, AND PRESS
START. EXECUTING···.
1.NOSIGNAL  2.33.6 V34  3.31.2 V34  4.28.8 V34
2.26.4 V34  6.24.0 V34  7.21.6 V34  8.19.2 V34
9.16.8 V34  10.14.4 V34 11.12.0 V34 12.9.6 V34
13.7.2 V34  14.4.8 V34  15.2.4 V34  16.14.4 V33
17.12.0 V33 18.14.4 V17 19.12.0 V17 20.9.6 V17
21.7.2 V17  22.9.6 V29  23.7.2 V29  24.4.8 V27t
25.2.4 V27t 26.0.3 FLG  27.CED 2100 28.CNG 1100
29.0.3 V21  30.ANSam    31.RINGER   32.No RBT
2
Same 
display
SIMULATION 66-4
SIGNAL OUTPUT CHECK.(LEVEL MAX)  SELECT 1-32, AND PRESS
START.
1.NOSIGNAL  2.33.6 V34  3.31.2 V34  4.28.8 V34
2.26.4 V34  6.24.0 V34  7.21.6 V34  8.19.2 V34
9.16.8 V34  10.14.4 V34 11.12.0 V34 12.9.6 V34
13.7.2 V34  14.4.8 V34  15.2.4 V34  16.14.4 V33
17.12.0 V33 18.14.4 V17 19.12.0 V17 20.9.6 V17
21.7.2 V17  22.9.6 V29  23.7.2 V29  24.4.8 V27t
25.2.4 V27t 26.0.3 FLG  27.CED 2100 28.CNG 1100
29.0.3 V21  30.ANSam    31.RINGER   32.No RBT
2
Press [CUSTOM SETTINGS] key.
Press [CUSTOM SETTINGS] key.
AR-M550/M620  SIMULATION  8 - 87
Operation/Procedure
1) Enter the number corresponding to the output mode with 10-key.
2) Press [START] key.
The output is delivered at the send level set with the soft switch.
When [CUSTOM SETTINGS] key is pressed during execution, execu-
tion is stopped. 
When a number is entered and [START] key is pressed during execu-
tion, the kind of signal can be changed.
66-5
Purpose
Operation test/Check
Function
(Purpose)
Used to check the output operation of data signals in 
each data output mode of FAX. (Used to check the 
operation of MODEM.) An output is sent at the send 
level set by the soft switch. (Only when FAX is 
installed)
Section
FAX
Item
Operation
1
NOSIGNAL
No signal
17
12.0 V33
12.0 V33
2
33.6 V34
26.4 V34
18
14.4 V17
14.4 V17
3
31.2 V34
31.2 V34
19
12.0 V17
12.0 V17
4
28.8 V34
28.8 V34
20
9.6 V17
9.6 V17
5
26.4 V34
26.4 V34
21
7.2 V17
7.2 V17
6
24.0 V34
24.0 V34
22
9.6 V29
9.6 V29
7
21.6 V34
21.6 V34
23
7.2 V29
7.2 V29
8
19.2 V34
19.2 V34
24
4.8 V27t
4.8 V27t
9
16.8 V34
16.8 V34
25
2.4 V27t
2.4 V27t
10
14.4 V34
14.4 V34
26
0.3 FLG
0.3 FLG
11
12.0 V34
12.0 V34
27
CED 2100
CED 2100
12
9.6 V34
9.6 V34
28
CNG 1100
CNG 1100
13
7.2 V34
7.2 V34
29
0.3 V21
0.3 V21
14
4.8 V34
4.8 V34
30
ANSam
ANSam
15
2.4 V34
2.4 V34
31
RINGER
RINGER
16
14.4 V33
14.4 V33
32
No RBT
No RBT
Press [START] key.
Enter 2 and press [START] key.
SIMULATION 66-5
SIGNAL OUTPUT CHECK.(SOFT SW.)  SELECT 1-32, AND PRESS
START.
1.NOSIGNAL  2.33.6 V34  3.31.2 V34  4.28.8 V34
2.26.4 V34  6.24.0 V34  7.21.6 V34  8.19.2 V34
9.16.8 V34  10.14.4 V34 11.12.0 V34 12.9.6 V34
13.7.2 V34  14.4.8 V34  15.2.4 V34  16.14.4 V33
17.12.0 V33 18.14.4 V17 19.12.0 V17 20.9.6 V17
21.7.2 V17  22.9.6 V29  23.7.2 V29  24.4.8 V27t
25.2.4 V27t 26.0.3 FLG  27.CED 2100 28.CNG 1100
29.0.3 V21  30.ANSam    31.RINGER   32.No RBT
1
SIMULATION 66-5
SIGNAL OUTPUT CHECK.(SOFT SW.)  SELECT 1-32, AND PRESS
START. EXECUTING···.
1.NOSIGNAL  2.33.6 V34  3.31.2 V34  4.28.8 V34
2.26.4 V34  6.24.0 V34  7.21.6 V34  8.19.2 V34
9.16.8 V34  10.14.4 V34 11.12.0 V34 12.9.6 V34
13.7.2 V34  14.4.8 V34  15.2.4 V34  16.14.4 V33
17.12.0 V33 18.14.4 V17 19.12.0 V17 20.9.6 V17
21.7.2 V17  22.9.6 V29  23.7.2 V29  24.4.8 V27t
25.2.4 V27t 26.0.3 FLG  27.CED 2100 28.CNG 1100
29.0.3 V21  30.ANSam    31.RINGER   32.No RBT
1
SIMULATION 66-5
SIGNAL OUTPUT CHECK.(SOFT SW.)  SELECT 1-32, AND PRESS
START. EXECUTING···.
1.NOSIGNAL  2.33.6 V34  3.31.2 V34  4.28.8 V34
2.26.4 V34  6.24.0 V34  7.21.6 V34  8.19.2 V34
9.16.8 V34  10.14.4 V34 11.12.0 V34 12.9.6 V34
13.7.2 V34  14.4.8 V34  15.2.4 V34  16.14.4 V33
17.12.0 V33 18.14.4 V17 19.12.0 V17 20.9.6 V17
21.7.2 V17  22.9.6 V29  23.7.2 V29  24.4.8 V27t
25.2.4 V27t 26.0.3 FLG  27.CED 2100 28.CNG 1100
29.0.3 V21  30.ANSam    31.RINGER   32.No RBT
2
Same 
display
SIMULATION 66-5
SIGNAL OUTPUT CHECK.(SOFT SW.)  SELECT 1-32, AND PRESS
START.
1.NOSIGNAL  2.33.6 V34  3.31.2 V34  4.28.8 V34
2.26.4 V34  6.24.0 V34  7.21.6 V34  8.19.2 V34
9.16.8 V34  10.14.4 V34 11.12.0 V34 12.9.6 V34
13.7.2 V34  14.4.8 V34  15.2.4 V34  16.14.4 V33
17.12.0 V33 18.14.4 V17 19.12.0 V17 20.9.6 V17
21.7.2 V17  22.9.6 V29  23.7.2 V29  24.4.8 V27t
25.2.4 V27t 26.0.3 FLG  27.CED 2100 28.CNG 1100
29.0.3 V21  30.ANSam    31.RINGER   32.No RBT
2
Press [CUSTOM SETTINGS] key.
Press [CUSTOM SETTINGS] key.
AR-M550/M620  SIMULATION  8 - 88
Operation/Procedure
1) Enter 1 with 10-key and press [START] key.
The paper is automatically selected with the size saved in the image
memory.
Operation/Procedure
All image data stored in the image memory are printed. 
The confidential receive data are also printed.
The paper is automatically selected with the size saved in the image
memory.
Operation/Procedure
1) Enter the number corresponding to the output mode with 10-key.
2) Press [START] key.
The output is delivered at the max. level.
When the number is entered during execution, the kind of signal can
be changed.
When [START] key is pressed, the voice message is sent. When
[CUSTOM SETTINGS] key is pressed, it is stopped.
66-6
Purpose
User data output/Check (Display/Print)
Function
(Purpose)
Used to print the confidential pass code. (Used when 
the confidential pass code is forgotten.) (Only when 
FAX is installed)
Section
FAX
Item
Data
1
PRINT START
Print start
66-7
Purpose
User data output/Check (Display/Print)
Function
(Purpose)
Used to print the image memory data (memory send/
receive). (Only when FAX is installed)
Section
FAX
Item
Data
1
PRINT START
Print start
 
(When 1)
SIMULATION 66-6
PASS CODE PRINT OUT. EXECUTING···.
1.PRINT START
SIMULATION 66-6
PASS CODE PRINT OUT.
PRESS START.
1.PRINT START 
When there is no print data, 
the display returns to the 
original state without printing.
Enter 1 and 
press [START] key.
After completion of printing
SIMULATION 66-7
IMAGE MEMORY PRINT OUT. PRESS START.
1.PRINT START
(When 1)
SIMULATION 66-7
IMAGE MEMORY PRINT OUT. EXECUTING···.
1.PRINT START
Enter 1 and 
press [START] key.
After completion of printing
66-8
Purpose
Operation test/Check
Function
(Purpose)
Used to check the output operation of various sound 
signals of FAX. (Used to check the operation of the 
sound output IC.) Send level: Max. (Only when FAX is 
installed)
Section
FAX
Item
Operation
1 NONE
Mute
11 MESSAGE 9
Message 9
2 PAUSE
Pause sound
12 MESSAGE 10 Message 10
3 MESSAGE1 Message 1
13 MESSAGE 11 Message 11
4 MESSAGE2 Message 2
14 MESSAGE 12 Message 12
5 MESSAGE3 Message 3
15 MESSAGE 13 Message 13
6 MESSAGE4 Message 4
16 MESSAGE 14 Message 14
7 MESSAGE5 Message 5
17 MESSAGE 15 Message 15
8 MESSAGE6 Message 6
18 ALARM
Alarm
9 MESSAGE7 Message 7
19 RINGER
Call ring
10 MESSAGE8 Message 8
20 EXT.TEL.RIN
GER
External TEL 
ring