DOWNLOAD Sharp AR-M550 (serv.man14) Service Manual ↓ Size: 2.46 MB | Pages: 44 in PDF or view online for FREE

Model
AR-M550 (serv.man14)
Pages
44
Size
2.46 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / (7) Settings and adjustments
File
ar-m550-sm14.pdf
Date

Sharp AR-M550 (serv.man14) Service Manual ▷ View online

AR-M550/M620  SETTING AND ADJUSTMENTS  7 - 16
Repeat the above adjustments until an acceptable result is obtained.
This adjustment is needed in the following situations: 
• The CCD unit has been removed from the machine. 
• The CCD unit has been replaced. 
• Images are not correctly magnified in the main scanning direction. 
• The MFP control PWB has been replaced.
• The EEPROM on the MFP control PWB has been replaced.
• The scan control PWB has been replaced.
• The EEPROM on the scan control PWB has been replaced.
• U2 trouble has occurred. 
3) Place a scale on the original table in parallel with the main scan-
ning direction, as illustrated below.
2) Make a normal copy on A4 paper.
3) Measure the lengths of the copied image of the scale and the
actual scale.
4) Determine the image magnification factor using the following for-
mula:
Image magnification factor (%) = Copy dimension/original dimen-
sion x 100
Example: Compare the copy and original dimensions by aligning
the scale’s 10 mm position with the copied image’s 10 mm posi-
tion.
Image magnification factor (%) = 99 / 100 x 100 = 99
If the image magnification factor is within the spec (100±0.8%), no
adjustment is required; otherwise, do the following steps. 
5) Go through the modes specified in Simulation 48-1.
ADJ 6
Adjusting the image 
magnification
Item
Set 
range
Default
0 TRAY SELECT
Paper feed tray selection
0 - 99
50
1 COPY START
Copy START (Default)
2 MAGNIFICATION Print magnification ratio
3 CCD (MAIN)
SCAN main scanning 
magnification ratio 
adjustment (CCD)
4 CCD (SUB)
SCAN sub scanning 
magnification ratio 
adjustment (CCD)
5 SPF (SUB)
SPF front surface 
magnification ratio 
adjustment (Sub scan)
6 CIS (MAIN)
SPF back surface 
magnification ratio 
adjustment (CIS main scan)
7 SPF (MAIN)
SPF front surface 
magnification ratio 
adjustment (Main scan)
ADJ 6A
Adjust the image magnification in the 
main scanning direction in original table 
mode (CCD)
10
20
30
40
50
60
70
80
90
100
110
120
130
140
10
20
90
100
110
10
20
90
100
110
100mm scale
(Original)
Copy image
(1mm (1%)
shorter than 
the original)
0.8mm
AR-M550/M620  SETTING AND ADJUSTMENTS  7 - 17
6) Select the number that corresponds to the adjustment item CCD
(MAIN) using the numeric keypad. 
This adjustment item is intended to adjust the image magnification
in the main scanning direction in original table mode (CCD). 
7) Press the Start key
8) Adjust the image magnification factor by entering an appropriate
value through the numeric keypad. 
9) Press the P or Start key
Pressing the Start key starts copy operation as well as applying the
adjustment value.
Repeat steps 2 to 9 until the image magnification factor is satisfactory.
This adjustment is needed in the following situations: 
• The CCD unit has been removed from the machine. 
• The CCD unit has been replaced. 
• Images are not correctly magnified in the sub-scanning direction. 
• The MFP control PWB has been replaced.
• The EEPROM on the MFP control PWB has been replaced.
• The scan control PWB has been replaced.
• The EEPROM on the scan control PWB has been replaced.
• U2 trouble has occurred. 
1) Place a scale on the original table as illustrated below.
2) Make a normal copy on A4 paper.
3) Measure the lengths of the copied image of the scale and the
actual scale.
4) Determine the image magnification factor using the following for-
mula:
Image magnification factor (%) = Copy dimension/original dimen-
sion x 100
Example: Compare the copy and original dimensions by aligning
the scale's 10 mm position with the copied image's 10 mm position.
Image magnification factor (%) = 99 / 100 x 100 = 99
If the image magnification factor is within the spec (100±0.8%), no
adjustment is required; otherwise, do the following steps.
Select 2, and 
press [START] key.
Press [START] key, or 
press [CUSTOM SETTINGS] key.
50
1
2
Select other than 0 - 2, 
and press [START] key.
Press [CUSTOM SETTINGS] key.
Press [START] key. 
Press [CUSTOM SETTINGS] key, 
or terminate copying.
Press [START] key, or 
press [CUSTOM SETTINGS] key.
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. SELECT 0-9, AND PRESS START.
0.TRAY SELECT 
1
 1.PRINT START
2.MAGNIFICATION 
100
3.CCD(MAIN) 
50
 4.CCD(SUB) 
50
 5.SPF(SUB) 
50
6.CIS(MAIN) 
50
 7.SPF(MAIN) 
50
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. INPUT VALUE 0-99, AND PRESS
START.
4.CCD(SUB)
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. NOW COPYING.
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. SELECT 1-15, AND PRESS START.
(FEED TRAY)
   1.TRAY1 2.TRAY2 3.TRAY3 4.TRAY4
   5.BPT   6.LCC
   (ABOVE+10: DUPLEX MODE)
Select 1, and 
press [START] key. 
Select 0, and press [START] key.
100
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT.
(MAGNIFICATION)
  INPUT 25-400(%)
ADJ 6B
Adjust the image magnification in the 
sub-scanning direction in original table 
mode
10 20 30 40 50 60 70 80 90 100110120130140
10
20
90
100
110
10
20
90
100
110
100mm scale
(Original)
Copy image
(1mm (1%)
shorter than 
the original)
0.8mm
AR-M550/M620  SETTING AND ADJUSTMENTS  7 - 18
5) Go through the modes specified in Simulation 48-1.
 
6) Select the number that corresponds to the adjustment item CCD
(SUB) using the numeric keypad.
This adjustment item is intended to adjust the image magnification
in the sub scanning direction in original table mode (CCD).
7) Press the Start key.
8) Adjust the image magnification factor by entering an appropriate
value through the numeric keypad.
9) Press the P or Start key
Pressing the Start key starts copy operation as well as applying the
adjustment value.
Repeat steps 2 to 9 until the image magnification factor is satisfactory.
This adjustment is needed in the following situations:
• The CCD unit has been removed from the machine.
• The CCD unit has been replaced.
• Images are not correctly magnified in the main scanning direction.
• The MFP control PWB has been replaced.
• The EEPROM on the MFP control PWB has been replaced.
• The scan control PWB has been replaced.
• The EEPROM on the scan control PWB has been replaced.
• U2 trouble has occurred.
1) On the SPF original tray, place such an original as illustrated
below.
2) Make a normal copy on A4 paper.
3) Measure the lengths of the copied image and the original image.
4) Determine the image magnification factor using the following for-
mula:
Image magnification factor (%) = Copy dimension/original dimen-
sion x 100
Image magnification factor (%) = 99 / 100 x 100 = 99
If the image magnification factor is within the spec (100±0.8%), no
adjustment is required; otherwise, do the following steps.
5) Go through the modes specified in Simulation 48-1.
Select 2, and 
press [START] key.
Press [START] key, or 
press [CUSTOM SETTINGS] key.
50
1
2
Select other than 0 - 2, 
and press [START] key.
Press [CUSTOM SETTINGS] key.
Press [START] key. 
Press [CUSTOM SETTINGS] key, 
or terminate copying.
Press [START] key, or 
press [CUSTOM SETTINGS] key.
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. SELECT 0-9, AND PRESS START.
0.TRAY SELECT 
1
 1.PRINT START
2.MAGNIFICATION 
100
3.CCD(MAIN) 
50
 4.CCD(SUB) 
50
 5.SPF(SUB) 
50
6.CIS(MAIN) 
50
 7.SPF(MAIN) 
50
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. INPUT VALUE 0-99, AND PRESS
START.
4.CCD(SUB)
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. NOW COPYING.
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. SELECT 1-15, AND PRESS START.
(FEED TRAY)
   1.TRAY1 2.TRAY2 3.TRAY3 4.TRAY4
   5.BPT   6.LCC
   (ABOVE+10: DUPLEX MODE)
Select 1, and 
press [START] key. 
Select 0, and press [START] key.
100
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT.
(MAGNIFICATION)
  INPUT 25-400(%)
ADJ 6C
Adjust the image magnification in the 
main scanning direction in SPF front-
face mode (CCD)
A4 size
10mm
10mm
original
10
50
100
150
200
250
copy
10
50
100
150
200
250
AR-M550/M620  SETTING AND ADJUSTMENTS  7 - 19
6) Using the numeric keypad, select the number that corresponds to
the mode for which to make adjustments. 
Select the adjustment item that is intended to adjust the image
magnification in the main scanning direction in SPF front-face
mode (CCD). 
7) Press the Start key
8) Adjust the image magnification factor by entering an appropriate
value through the numeric keypad. 
9) Press the P or Start key
Pressing the Start key starts copy operation as well as applying the
adjustment value. 
Repeat the above adjustments until an acceptable result is obtained. 
This adjustment is needed in the following situations: 
• The MFP control PWB has been replaced.
• The EEPROM on the MFP control PWB has been replaced.
• The scan control PWB has been replaced.
• The EEPROM on the scan control PWB has been replaced.
• U2 trouble has occurred. 
• Images are not correctly magnified in the main scanning direction. 
1) On the SPF original tray, place such a duplex original as illustrated
below.
2) Make a normal duplex copy on A4 paper.
3) Measure the lengths of the copied image (on the back side) and
the original image.
4) Determine the image magnification factor using the following for-
mula:
Image magnification factor (%) = Copy dimension/original dimen-
sion x 100
Image magnification factor (%) = 99 / 100 x 100 = 99
If the image magnification factor is within the spec (100±0.8%), no
adjustment is required; otherwise, do the following steps. 
Select 2, and 
press [START] key.
Press [START] key, or 
press [CUSTOM SETTINGS] key.
ADJ 6D
Adjust the image magnification in the 
main scanning direction in SPF back-
face mode (CCD)
50
1
2
Select other than 0 - 2, 
and press [START] key.
Press [CUSTOM SETTINGS] key.
Press [START] key. 
Press [CUSTOM SETTINGS] key, 
or terminate copying.
Press [START] key, or 
press [CUSTOM SETTINGS] key.
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. SELECT 0-9, AND PRESS START.
0.TRAY SELECT 
1
 1.PRINT START
2.MAGNIFICATION 
100
3.CCD(MAIN) 
50
 4.CCD(SUB) 
50
 5.SPF(SUB) 
50
6.CIS(MAIN) 
50
 7.SPF(MAIN) 
50
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. INPUT VALUE 0-99, AND PRESS
START.
4.CCD(SUB)
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. NOW COPYING.
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. SELECT 1-15, AND PRESS START.
(FEED TRAY)
   1.TRAY1 2.TRAY2 3.TRAY3 4.TRAY4
   5.BPT   6.LCC
   (ABOVE+10: DUPLEX MODE)
Select 1, and 
press [START] key. 
Select 0, and press [START] key.
100
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT.
(MAGNIFICATION)
  INPUT 25-400(%)
A4 size
(both sides)
10mm
10mm
original
10
50
100
150
200
250
copy
10
50
100
150
200
250
Page of 44
Display