AR-FX4 SOFT SWITCH DESCRIPTIONS - 2
2. Soft switch list
When outside the set range, the default value is automatically set.
Never change the soft switch setup which are inhibited to use.
Reception print
Paper selection
Sub scan length 
judgment
NO
When print is not made on selected paper.
Output condition setup
Reception function setup
To make divided print instead of reduction 
print
Automatic reduction print Reception function setup
When reduction print is not made.
Magnification ratio in 
automatic reduction
NO
When reduction print is not made on a fixed 
size paper.
Rotation reception print
NO
When rotation print is not made.
Reception size setup
Reception function setup
Reception capacity is indicated on the 
transmission machine.
Index
Index print setup
Reception function setup
When  an index is added to received data.
Large item
Medium item
Switch content
Key operator
Soft SW No.
Purpose of use
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
S
W
1
1
Size specification
Bit No.
1
2
Conforms to the 
machine information.
0
When set to 
conformity to the 
machine 
information, if 
machine 
information is 
uncertain, set to 
centimeter size.
Centimeter size
0
0
Inch size
1
0
2
Conforms to the machine 
information.
0
1
1
Conforms to the machine 
information.
1
1
3
Inhibited to use
0
4
Auto/Manual default 
setup
1: Manual reception
0: Automatic reception
Automatic reception
0
Manual 
reception can be 
set only when 
external 
telephone is 
connected.
5
Send request protection 1: Not protected
0: Protected
Protected
0
6
Reduction send mode
1: Normal
0: Reduction
Reduction
0
7
Contents of send 
document are printed in 
memory send error
1: Not print
0: Print
Print
0
8
Inhibited to use
0
S
W
2
1
Inhibited to use
0
2
0
3
0
4
0
5
Remote selection 
number setup
Binary input
5
0 When a value 
outside the set 
range is set, the 
initial value is 
set.
6
Bit No.
Set range
5
6
7
8
0 to 9
1
7
0
8
1
S
W
3
1
Density default setup
Bit No.
1
2
3
4
5
Auto
0
Auto
0
0
0
0
0
2
Light
1
0
0
0
0
0
Slightly light
0
1
0
0
0
3
Medium
0
0
1
0
0
0
Slightly dark
0
0
0
1
0
4
Dark
0
0
0
0
1
0
5
0
6
Image quality priority 
selection
Bit No.
6
7
8
Normal
0
Normal
0
0
0
Fine
0
0
1
7
Super fine
0
1
0
0
Ultra fine
0
1
1
Not used
1
0
0
8
Fine + half-tone
1
0
1
0
Super fine + half-tone
1
1
0
Ultra fine + half-tone
1
1
1
AR-FX4 SOFT SWITCH DESCRIPTIONS - 3
S
W
4
1
Recall interval in 
communication error
Binary input
1min
0
2
Bit No.
Set range
1
2
3
4
0 to 15min
0: Immediate recall after 
disconnection of line
0
3
0
4
1
5
Recall interval in busy
Binary input
3min
0 When a value 
outside the set 
range is set, the 
initial value is 
set.
6
Bit No.
Set range
5
6
7
8
1 to 15min
0
7
1
8
1
S
W
5
1
Line equivalent unit [km]
Bit No.
1
2
No Filter
0
When a value 
outside the set 
range is set, the 
initial value is 
set.
No Filter
0
0
1.8km
0
1
2
3.6km
1
0
0
7.2km
1
1
3
Inhibited to use
0
4
1
5
Signal send level
Binary input
–11dBm
0
6
Bit No.
Set range
5
6
7
8
–4 to –19dBm
1
7
1
8
1
S
W
6
1
ECM
1: YES
0: NO
YES
1
2
CED signal send
1: YES
0: NO
YES
1
3
CSI transmission
1: YES
0: NO
YES
1
4
DIS reception 
confirmation in G3 send
1: 2 times
0: Once in NSF reception
2 times in DIS reception
Once in NSF 
reception, 2 times in 
DIS reception
0
5
Non-modulation carrier 
in V.29 send
1: YES
0: NO
NO
0
6
EOL detection timer
1: 25sec
0: 13sec
13sec
0
7
Countermeasure for 
echo in reception
(CED tone send 
interval)
1: 500ms
0: 75ms
75ms
0
8
Countermeasure for 
echo in transmission
(After reception of DIS, 
hold time up to signal 
send is set.)
1: 500ms
0: 200ms
200ms
0
S
W
7
1
MH fixed
1: YES
0: NO (depending on the other 
party’s machine)
NO
0
2
Dial tone detection
1: YES
0: NO
NO
0
3
Busy tone detection
1: YES
0: NO
YES
1
4
Dial tone monitoring 
time
1: 10sec
0: 5sec
5sec
0
5
Inhibited to use
0
6
Max. length of reception 1: No limit
0: 1.5m
1.5m
0
7
Modem speed in 
reception fixed
Bit No.
7
8
No fixing
0
No fixing
0
0
V.29-9600BPS
0
1
8
V.27ter-4800BPS
1
0
0
V.17-14400BPS
1
1
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
AR-FX4 SOFT SWITCH DESCRIPTIONS - 4
S
W
8
1
Memory transmission/
direct transmission 
default setup
1: Direct transmission
0: Memory transmission
Memory transmission
0
2
Proxy reception
1: YES
0: NO
YES
1
3
Printing the content of 
transmitted document in 
normal memory 
transmission
1: Not print
0: Print
Not print
1
4
Judgment of system No. 
in bulletin transmission
1: Allow
0: Inhibit
Inhibit
0
5
Remote reception 
indication
1: YES
0: NO
YES
1
6
Inhibited to use
0
7
1
8
0
S
W
9
1
Print of total 
communication time 
and total pages
1: YES
0: NO
YES
1
2
Inhibited to use
1
3
Quick memory 
transmission
1: Allow
0: Inhibit
Allow
1
4
Yes/No of SUB capacity 
in reception
1: NO
0: YES
YES
0
5
F-code relay broadcast 
function
1: Inhibit
0: Allow
Allow
0
6
F-code confidential 
reception function
1: Inhibit
0: Allow
Allow
0
7
Yes/No of SEP capacity 
in reception
1: NO
0: YES
YES
0
8
Yes/No of reception 
PWD capacity
1: Send without password
0: Disconnection of line with 
DCN
Disconnection of line 
with DCN
0
S
W
10
1
Measurement of 
communication time 
(image)
1: YES
0: NO
YES
1
2
Sender’s telephone 
number registration
1: Inhibit
0: Allow
Allow
0
3
Yes/No of reception SID 
capacity
1: Send without password
0: Disconnection of line with 
DCN
Disconnection of line 
with DCN
0
4
SDT signal detection
1: YES
0: NO
NO
0
5
Inhibited to use
0
6
0
7
ECM MMR mode
1: YES
0: NO
YES
1
8
ECM JBIG mode
1: YES
0: NO
YES
1
S
W
11
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
12
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
CI detection
Bit No.
6
7
4 sine wave
0
When a value 
outside the set 
range is set, the 
initial value is 
set.
4 sine wave
0
0
3 sine wave
1
0
7
2 sine wave
0
1
0
1
1
8
Inhibited to use
0
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
AR-FX4 SOFT SWITCH DESCRIPTIONS - 5
S
W
13
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
Relay data output
1: YES
0: NO
YES
1
8
Relay broadcast 
function
1: Allow
0: Inhibit
Allow
1
S
W
14
1
V.34 mode sending 
speed
Binary input
33600bps
1
2
Bit No.
1
2
3
4
1
3
Sending speed = 
2400(bps) x N
When N=0, 2400bps.
When N=15, 33600bps.
1
4
0
5
V.34 mode reception 
speed
Binary input
33600bps
1
6
Bit No.
5
6
7
8
1
7
Reception speed = 
2400(bps) x N
When N=0, 2400bps.
When N=15, 33600bps.
1
8
0
S
W
15
1
Busy tone detection 
time (Lower limit)
1: 350ms
0: 250ms
250ms
0
2
Busy tone detection 
time (Upper limit)
1: 650ms
0: 750ms
750ms
0
3
Busy tone detection 
time (Lower limit 2)
1: 150ms
0: Follows SW15-1.
Follows SW15-1.
0
4
Inhibited to use
0
5
Modem speed
(V.33 mode or below)
Bit  No.
5
6
7
8
V.17 14.4kbps
1
V.27 2400bps
0
0
0
0
V.29 9600bps
0
0
0
1
6
V.27 4800bps
0
0
1
0
0
V.29 7200bps
0
0
1
1
7
V.33 14.4kbps
0
1
0
0
0
V.33 12.0kbps
0
1
1
0
8
V.17 9600bps
1
0
0
1
0
V.17 12.0kbps
1
0
1
0
V.17 7200bps
1
0
1
1
V.17 14.4kbps
Others
S
W
16
1
Inhibited to use
0
2
External telephone 
connection
1: YES
0: NO
YES
1
3
Inhibited to use
0
4
0
5
Rotation transmission 
selection
(11 x 8.5 
 8.5 x 11)
1: YES
0: NO
YES
1
6
Rotation transmission 
selection (A4 
 A4R)
1: YES
0: NO
YES
1
7
Rotation transmission 
selection (B5R 
 B5)
1: YES
0: NO
YES
1
8
Rotation transmission 
selection (A5 
 A5R)
1: YES
0: NO
YES
1
S
W
17
1
Paper selection priority 
sequence
1: Width priority
0: Area priority
Area priority
0
2
Output condition setup
Bit No.
2
3
Reduction allowed
0
When a value 
outside the set 
range is set, the 
initial value is 
set.
Reduction allowed
0
0
3
Division allowed
1
0
0
4
Inhibited to use
0
5
1
6
1
7
1
8
1
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
Page of 74