AR-FX4 SIMULATION - 2
*1. The negative value of the set value corresponds to the grid high
output voltage.
*2. The set values can be selected from the above 8 patterns only.
*3. The selected pattern determines the grid high voltage and the grid
low voltage.
If, for example, the grid high voltage is set to –480V (pattern 1), the
grid low voltage is –350V.
Operation/procedure
Enter the adjustment value and press the [OK] key, and output opera-
tion is performed for 30sec.
*1. The negative value of the set value corresponds to the grid high
output voltage.
*2. The set values can be selected from the above 8 patterns only.
*3. The selected pattern determines the grid high voltage and the grid
low voltage.
If, for example, the grid high voltage is set to –480V (pattern 1), the
grid low voltage is –350V.
Operation/procedure
The current counter value (number of send/receive pages) of the FAX
send/receive counter and the accumulated reception time and the print
counter are displayed.
Note: Executable only when the FAX is installed.
Operation/procedure
The current counter value (number of send/receive pages) of the FAX
send/receive counter and the accumulated reception time and the print
counter are cleared to 0.
Note: Executable only when the FAX is installed.
Operation/procedure
Set the job separator.
 
Operation/procedure
Input the set value with the 10-key and press the [OK] key.
This setup varies in connection with SIM 26-6 (Destination setup).
NO.
Set value
Grid High 
Grid Low
1 480
–480V
–350V
2 505
–505V
–375V
3
530
–530V
–400V
4
555
–555V
–425V
5
580
–580V
–450V
6 605
–605V
–475V
7 630
–630V
–500V
8 655  –655V
–525V
8-15
Purpose
Adjustment/Operation test/check
Function 
(Purpose)
Used to check and adjust the operation of the main 
charger grid voltage (low mode) in FAX mode and the 
control circuit.
Section
Image process (Photoconductor/Developping/
Transfer/Cleaning)
Photo conductor
(Initial screen)
(Executing screen)
Setting range
1-8
Default
5
NO.
Set value
Grid High 
Grid Low
1 480
–480V
–350V
2 505
–505V
–375V
3
530
–530V
–400V
4
555
–555V
–425V
5
580
–580V
–450V
6 605
–605V
–475V
7 630
–630V
–500V
8 655  –655V
–525V
22
22-11
Purpose
Adjustment/Setting/Check
Function 
(Purpose)
FAX related counter display
Sim8-15 MHV(L) FAX
FAX               5
EXEC [  1-  8]  
  5
Sim8-15 MHV(L) FAX
FAX               5
EXEC
 [  1-  8]   
 5
24
24-10
Purpose
Adjustment/Setting/Check
Function 
(Purpose)
FAX related counter clear
26
26-1
Purpose
Setting
Function 
(Purpose)
Used to set options. (This simulation is used to make 
option setting when an option is installed.)
Item
Specifications
Option
Set value
Connection option
0
None (default)
1
Job separator provided.
26-60
Purpose
Setting
Function 
(Purpose)
Used to set enable/disable of the FAX mode key when 
FAX is not installed. (When FAX is installed, the FAX 
mode is enabled regardless of this setup.)
Item
Operation
Display 
items
Content
Setting 
range
Default
JAPAN, 
SEC, SECL, 
SUK, SCA
Others
0:ON
Effective (The 
message with FAX 
uninstalled is 
displayed.)
0-1
0
1
1:OFF
Disable (Error Beep)
Sim26-1 OPTION SET.
JOB SEPARATOR     0
  (0:NONE
   1:JOB SEPARATOR)
     [  0-  1]    
0
Sim26-60  FAX KEY
FAX KEY SETTING   0
  (0:ON 1:OFF)
     [  0-  1]    
0
AR-FX4 SIMULATION - 3
Operation/procedure
Shading is performed to turn on the copy LED.
The current exposure value of "Normal character, Auto exposure"
mode is displayed.
Enter an adjustment value of 2 digits with the 10-key and press the
START key, and the entered value will be set to all the modes and the
self print will be made in the normal size.
Exposure adjustment value table
When initializing each data: 50
Note: Executable only when the FAX is installed.
Operation/procedure
The FAX exposure level can be adjusted separately for each mode by
specifying a sub code. Since selection of Auto/Manual and Photo ON/
OFF is allowed separately for each mode, adjustments of 14 patterns
in total can be made. 
(Refer to 46-12, "Exposure adjustment table".)
Shading is performed to turn on the copy LED.
The current exposure value of the selected mode is displayed.
Enter the 2-digit adjustment value with the 10-key pad and push
START key. The entered value is set for the specified mode, and the
self print is made with the same magnification ratio for the mode.
Note: Executable only when the FAX is installed.
Operation/procedure
Adjust and set FAX document read magnification ratio, read and print
the document.
Note: Executable only when the FAX is installed.
Operation/procedure
After the adjustment/setting of FAX print magnification ratio, read and
print the document.
Note: Executable only when the FAX is installed.
Operation/procedure
Set the FAX auto reduction magnification ratio (0 to 15%).
Note:Executable only when the FAX is installed.
Operation/procedure
Adjust and set FAX document read lead edge position, read and print
the document.
46
46-12
Purpose
Adjustment
Function 
(Purpose)
FAX exposure level adjustment (batch)
Mode
AE
Photo
Exposure adjustment
STD
(Standard 
character)
Auto
ON
Manual
Auto
OFF
Individual adjustment 
enable
(46-13 to 16)
Manual
Fine
(Small 
character)
Auto
ON
Manual
Auto
OFF
Manual
S-fine
(Fine)
Auto
ON
Manual
Auto
OFF
Manual
U-fine
(Super fine)
Auto
ON
Manual
Auto
OFF
Manual
46-13 to 16
Purpose
Adjustment
Function 
(Purpose)
FAX exposure level adjustment (individual)
Sub code
Mode
13
STD (normal character)
14
Fine (small character)
15
S-fine (super fine)
16
U-fine (super fine)
48
48-8
Purpose
Adjustment
Function 
(Purpose)
FAX magnification ratio adjustment (read)
Related soft 
SW
SW76-1 to 8, SW77-1 to 8
Adjustment magnification ratio
Adjustment 
range
Adjustment 
unit
OC read main scanning 
magnification ratio
1 – 128 – 
255%
0.1% 
increment
OC read sub scanning 
magnification ratio
SPF read main scanning 
magnification ratio
SPF read sub scanning 
magnification ratio
48-9
Purpose
Adjustment
Function 
(Purpose)
FAX magnification ratio adjustment (print)
Related soft SW
SW78-1 to 8, SW79-1 to 8
Adjustment magnification ratio
Adjustment 
range
Adjustment 
unit
Main scanning magnification ratio
1 – 128 – 
255%
0.1% 
increment
Sub scanning magnification ratio
48-10
Purpose
Adjustment
Function 
(Purpose)
FAX auto reduction magnification ratio (print).
Related soft SW
SW25-1 to 4
50
50-8
The adjustments on the machine side must have been normally 
completed.
Purpose
Adjustment
Function 
(Purpose)
FAX lead edge adjustment (read)
Related soft SW
SW44-1 to 4, SW44-5 to 8
SW45-1 to 4, SW45-5 to 8
AR-FX4 SIMULATION - 4
Note: Executable only when the FAX is installed.
Operation/procedure
After the adjustment/setting of FAX print lead edge position, read and
print the document.
Note: Executable only when the FAX is installed.
Operation/procedure
Display FAX software SW on LCD, and set/change those with 10-key.
Note: Executable only when the FAX is installed.
Operation/procedure
Used to clear the FAX-related soft switches except for the line signal
adjustment value and the machine adjustment value and to set default
values (which differ depending on the country code separately
entered.)
Note: Executable only when the FAX is installed.
Operation/procedure
Read/write can be checked for FAX PWB memory.
The check result is displayed separately for each memory.
1.
Memory to be checked
2.
Detailed procedure
Interruption cannot be made during operation.
Note: Executable only when the FAX is installed.
Operation/procedure
By setting the message No., the signal is sent to the line and the
speaker of the body. (The signal is continuously sent until the interrup-
tion command is provided by pressing the [BACK] key.)
The signal send level can be selected from 0dB or the soft SW set
value. However, the level setup is not required for 01, 31 - 35, the
selection may does not appear. After completion of the mode, the sig-
nal send level is returned to the soft SW set value before execution of
the mode.
Adjustment position
Adjustment range
Adjustment 
unit
A
OC read lead edge position
43 – 50 – 57 lines
8 lines
B
OC read left edge position
43 – 50 – 57 dots
8 dots
C
OC read rear edge position
43 – 50 – 57 lines
8 lines
D
OC read right edge position
43 – 50 – 57 dots
8 dots
E
SPF read lead edge position
43 – 50 – 57 lines
8 lines
F
SPF read left edge position
43 – 50 – 57 dots
8 dots
G
SPF read rear edge position
43 – 50 – 57 lines
8 lines
H
SPF read right edge position
43 – 50 – 57 dots
8 dots
50-9
Purpose
Adjustment
Function 
(Purpose)
FAX lead edge adjustment (print)
Related soft SW
SW74-1 to 4, SW75-5 to 8
Adjustment position
Adjustment range
Adjustment 
unit
A
Lead edge position
43 – 50 – 57 lines
16 lines
B
Left edge position
43 – 50 – 57 dots
16 dots
66
66-1
Purpose
Adjustment/Setting/Check
Function 
(Purpose)
FAX related soft SW setting
66-2
Purpose
Adjustment/Setting/Check
Function 
(Purpose)
Initial set for the value of the FAX soft SW
OC read
SPF read
Read area
Read area
A
B
E
F
D
C
H
G
66-3
Purpose
Adjustment/Setting/Check
Function 
(Purpose)
FAX PWB memory check
DRAM
SRAM
Flash ROM
Program area
SUM check only
Memory area
Option memory
The memory size follows the 
automatically detected value.
PAGE
1
"55H" is written to all the addresses of each memory, and the 
address data are read in sequence to check that they were 
properly written.
2
"AAH" is written to all the addresses of each memory, and the 
address data are read in sequence to check that they were 
properly written.
3
"00H" is written to all the addresses of each memory, and the 
address data are read in sequence to check that they were 
properly written.
4
Perform checks 1 - 3 sequentially. If there is no abnormality, it is 
"OK." If there is any abnormality, "NG" is notified to the error 
address.
5
After completion of check, the memory is returned to the initial 
state.
(CPU is not reset)
66-4
Purpose
Adjustment/Setting/Check
Function 
(Purpose)
Signal send mode
Related soft 
SW
SW5-5 to 8 (signals send level)
SW23-1 to 4 (RBT ON time)
SW23-5 to 8 (RBT OFF time)
SW43-1 to 5 (DTMF signal send time)
Signal 
number
Send signal
Send level
Selection menu
01
Signal not send
None
26
7EH Flag signal
Yes
27, 28, 30
Tone signal
Yes
31
Pseudo-ringer sound
([ON HOOK] key ON)
None
32
Voice message (no sound)
None
Under the state where the ring back 
tone can be sent to the line, keep 
the sound composition IC volume to 
0.
AR-FX4 SIMULATION - 5
Note: Executable only when the FAX is installed.
Operation/procedure
The confidential ID table (confidential BOX numbers, confidential BOX
names, and confidential password) is printed. 
The confidential data of My company mode is printed separately.
Note: Executable only when the FAX is installed.
Operation/procedure
Used to input all image data (including confidential reception data,
remote send image, not-sent image) stored in image memory of the
FAX section.
The output image is remained even after outputting.
Note: Executable only when the FAX is installed.
Operation/procedure
Used to clear all image data (including confidential reception data)
stored in image memory of the FAX section.
The management table is also cleared (initialized) at the same time.
Note: Executable only when the FAX is installed.
Operation/procedure
By setting the signal number, the specified signal is delivered to the
line at the speed of 300bps. (The signal is continuously sent until the
interruption command is provided by pressing the [BACK] key.)
The signal send level can be selected from 0dB or the soft SW set
value.
The signal send level is returned to the soft SW set value before exe-
cution of the mode after completion of the mode.
Note: Executable only when the FAX is installed.
Operation/procedure
The send test of dial pulse and DTMF signal is performed and the
make time adjustment of dial pulse and the DTMF signal send level
adjustment are performed if necessary.
• Used to set the make time. By performing the test, the registered
dial pulse of max. 100 digits can be sent from the line.
• When "*" and "#" are included in the registered dial number, they are
disregarded and the number is not processed as a dial.
• The make time set in the dial test is written into the corresponding
soft SW.
• Default: 1 2 3 4 5 6 7 8 9 0
Operate the  [ 
 ] [ 
 ] key in DP dial selection menu to switch.
(Time before pulse delivery can be changed as 2sec 
 4sec 
8sec.)
• Set the signal send level to 0dB or the soft SW set value.
Used to set the high level group and the  low level group of DTMF
signal send level. By executing the test, DTMF signal is sent from
the line to a recorded dial number of max. 100 digits.
• The high group/low group value of the DTMF signal send level set in
the dial test is written into the corresponding soft SW.
• Default: 1 2 3 4 5 6 7 8 9 * 0 #
In the PB dial select menu, press [
][
] keys to select. 
Pressing the [CLEAR] key during the operation clears the input
value and returns to the value input menu.
• Max. 100 digits can be assigned to each dial (0 - 9, *, #). While the
default value is displayed at first, a desired value can be entered and
the entered value is stored on the FAX side until the menu is can-
celed.
• After completion of the mode, the signal send level is returned to the
soft SW set value before execution of the mode.
Note: Executable only when the FAX is installed.
33
Ring back tone (no sound)
None
Under the state where the ring back 
tone can be sent to the line, keep 
the G/A volume to 0.
34
Dial pulse (make)
1: 0dB
2: Soft SW
Maintain the make state with 
keeping the condition to be able to 
send to the dial pulse line.
35
Dial pulse (break)
1: 0dB
2: Soft SW
Maintain the break state with 
keeping the condition to be able to 
send to the dial pulse line.
Other than 
the above
FFH
Yes
66-6
Purpose
Adjustment/Setting/Check
Function 
(Purpose)
Printing the confidential password
66-7
Purpose
Adjustment/Setting/Check
Function 
(Purpose)
Print the screen memory contents
66-10
Purpose
Adjustment/Setting/Check
Function 
(Purpose)
Image data memory clear
66-11
Purpose
Adjustment/Setting/Check
Function 
(Purpose)
300bps signals send
Signal 
number
Send signal
Send level
Selection menu
Number
Signal
Number
Signal
1
No signal (CML ON)
4
00000
2
11111
5
010101
3
11110
6
00001
66-13
Purpose
Adjustment/Setting/Check
Function 
(Purpose)
Send test and adjustment of the dial pulse and 
DTMF signal.
Related soft SW
SW53-1 to 4 (DTMF high group end level)
SW53-5 to 8 (DTMF low group send level)
SW67-1 to 4 (DP 10PPS make time)
SW67-5 to 8 (DP 10PPS make time)
1.
Dial pulse (10pps) send test
2.
Dial pulse (20pps) send test
3.
DTMF signal send test
Make time
1ms for input value of 1. Adjust so that the dial pulse 
make rate is within 33±3%. (For North America,  
40±3%.)
Dial pulse make rate =
Make time / (Make time + Break time)
Break time
It is obtained from the formula below and 
automatically set.
PPS = 1000 / (make time + break time)
DTMF signal 
adjustment
The signal send levels are classified into the high 
group and the low group. The send level is 0.5dB for 
each 1 of input value.
Page of 74
Display

Click on the first or last page to see other AR-FX4 service manuals if exist.