AR-FX4 SOFT SWITCH DESCRIPTIONS - 18
S
W
89
1
Speaker volume of 
communication end 
sound
Bit No.
1
2
Medium
1
Silent
0
0
Small
0
1
2
Medium
1
0
0
Large
1
1
3
Pattern number of 
communication end 
sound
Binary input
21
0
4
Bit No.
Set range
3
4
5
6
7
8
Pattern number 1 to 35
1
5
0
6
1
7
0
8
1
S
W
90
1
Inhibited to use
0
2
0
3
0
4
1
5
1
6
0
7
0
8
0
S
W
91
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
92
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
93
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
94
1
Inhibited to use
0
2
0
3
0
4
0
5
0
6
0
7
0
8
0
S
W
95
1
Inhibited to use
1
2
1
3
0
4
0
5
0
6
0
7
1
8
1
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
AR-FX4 SOFT SWITCH DESCRIPTIONS - 19
3. Soft switch descriptions
SW1 No.1, No.2 Size specification
Used to set inch series or AB series for recording paper when printing
received documents.
There is normally no need to change from "Depends on the machine
information."
SW1 No.3 Inhibited to use
SW1 No.4 Auto/Manual default setup
Used to select Auto/Manual reception mode when turning on the
power. (When no external telephone is connected, do not select Man-
ual. However, setup is possible and reception can be made by on-
hook.)
When set to 1, manual reception.
When set to 0, auto reception.
Default: 0 (auto reception)
SW1 No.5 Send request protection
Used to set YES/NO of the confidential protection function (inhibition of
transmission to an erroneous party). Confidential protection is per-
formed by collating the number registered in this machine and that in
the other party’s machine. (Sender’s telephone number 
←→
 Send
request allow number, System number 
←→
 ID number)
When set to 1, protection is not made.
When set to 0, protection is made.
Default: 0 (protection enable)
SW1 No.6 Reduction send mode
Used to set whether the transmitted document is received in reduction
size or both ends of recording paper are cut when the transmitted doc-
ument width is greater than the recording paper width.
When set to 1, both ends are cut without reduction and transmitted.
When set to 0, it is reduced and transmitted.
Default: 0 (Reduction transmission)
SW1 No.7 Contents of send document are printed in 
memory send error
Used to set Print/Not print part of the sent document in the transmis-
sion result table in case of a memory transmission error.
When set to 1, the transmitted document is not printed on the transmis-
sion result table.
When set to 0, the transmitted document is printed on the transmission
result table.
Default: 0 (Print transmitted documents)
SW1 No.8 Inhibited to use
SW2 No.1 – No.4 Inhibited to use
SW2 No.5 – No.8 Remote selection number setup
Used to set the number by binary input for remote switch reception
from an external telephone. "**" in a remote switch number (X**) is
fixed.
When 10 or greater value is entered, the operations will be the same
as setup of 5.
Default: Setup of 5 as 0101
SW3 No.1 – No.5 Density default setup
Used to set the default setup of density of the operation panel.
SW3 No.6 – No.8 Image quality priority selection
Used to set the initial value of image selection when scanning a docu-
ment.
When set to 100, the operations are the same as the normal mode.
Default: 000 (Normal mode)
SW4 No.1 – No.4 Recall interval in communication error
Used to set recall interval after disconnection of communication due to
a communication error in memory transmission.
The set range is 0 to 15 min in the increment of 1 min by binary input.
When set to 0, recall is made immediately after disconnection.
However, the time interval set by SW21 (Interval between the end of a
communication and the next call) is taken.
Default: 0001 (1 min)
SW4 No.5 – No.8 Recall interval in busy
Used to set recall interval after disconnection of communication due to
the busy state of the other party or no response.
Can be set in the range of 1 – 15min by increment of 1min by binary
input.
When set to 0 min, it is the same as setup of 3 min.
Default: 0 0 1 1 (3 min)
SW5 No.1, No.2 Line equivalent unit [km]
Used to set the modem filter coefficient.
SW5 No.3, No.4 Inhibited to use
SW5 No.5 – No.8 Signal send level
Used to set the attenuation quantity of signal send level from the
modem. The actual output level to the line pin is further attenuated by
–4dBm. (When set to 2, the actual level on the line is about –6dBm.)
Default: 0111 (–11dBm)
S
W
96
1
Inhibited to use
0
2
1
3
1
4
1
5
0
6
1
7
0
8
1
S
W
97
1
Inhibited to use
1
2
0
3
0
4
1
5
0
6
0
7
0
8
0
SW 
NO.
Data 
No.
Item
Switch selection and contents of functions
Initial value
Remark
AR-FX4 SOFT SWITCH DESCRIPTIONS - 20
SW6 No.1 ECM
Used to set whether ECM (Error Correction Mode) is performed or not.
When, however, SW52-7 (V.34 mode function) is set to OFF, or when
SW52-7 (V.34 mode function is set to ON and the transmission is not
the super G3 transmission, ECM Disable setup is effective. This is
because the ECM function is indispensable in a transmission other
than super G3 transmission in V.34 mode and the other party machine
may perform checking. With SW52-7 (V.34 mode function) is ON and
this reception function is disabled.
When set to 1, ECM is enabled.
When set to 0, ECM is disabled.
Default: 1 (ECM enabled)
SW6 No.2 CED signal send
Used to set whether CED signal is sent or not. This setup is effective
only when SW52-7 (V.34 mode function) is off. This is because V.34
mode requires sending of ANSam signal.
When set to 1, CED (ANSam) signal is sent.
When set to 0, CED (ANSam) signal is not sent.
Default: 1, CED (ANSam) signal is sent.
SW6 No.3 CSI transmission
CSI signal includes the telephone number registered as sender’s num-
ber. Used to set whether this signal is sent or not.
When set to 1, CSI signal is sent.
When set to 0, CSI signal is not sent.
Default: 1 (CSI signal is sent.)
SW6 No.4 DIS reception confirmation in G3 send
Used to set whether DIS reception is checked or not in G3 mode.
When set to 1, DIS reception is always checked twice.
When set to 0, NSF/DIS reception is checked once, or DIS reception
without NSF is checked twice.
Default: 0 (NSF reception is checked once, DIS without NSF is
checked twice.)
SW6 No.5 Non-modulation carrier in V.29 send
Used to set whether non-modulation carriers are sent or not in V.29
transmission.
When set to 1, non-modulated carrier is sent.
When set to 0, non-modulated carrier is not sent.
Default: 0 (Non-modulated carrier is not sent.)
SW6 No.6 EOL detection timer
Used to set the detection timer of EOL (End Of Life) when Phase-C
reception.
When set to 1, the timer is set to 25sec.
When set to 0, the timer is set to 13sec.
Default: 0 (13sec)
SW6 No.7 Countermeasures for echo in reception (CED 
tone send interval)
Used to select ON/OFF of countermeasures against echo.
An interval of 500ms is inserted before DIS transmission.
Default: 0 (75ms)
SW6 No.8 Countermeasure for echo in transmission
(After reception of DIS, hold time up to signal send is set.)
An interval of 500ms is inserted before DCS transmission.
Default: 0 (200ms)
SW7 No.1 MH fixed
Used to fix the image data compression method in communication.
Normal setting
When set to 0, automatic selection of MH/MR/MMR is performed
according to the other party machine’s capacity.
When set to 1, MH fixed. This is effective when communication is
made only with MH machine or when images are disturbed due to poor
conditions of the line.
When SW52-7 (V.34 mode function) is OFF or when SW52-7 (V.34
mode function) is ON in transmission, MH fixing is enabled.
This is because the MMR function is indispensable in V.34 mode and
the other party machine checks that. When SW52-7 (V.34 mode func-
tion) is ON in reception, this function is disabled.
SW7 No.2 Dial tone detection
Used to set whether dial tone detection is performed or not in auto dial
ringing.
"1": YES
"0": NO
When set to YES and dial tone is not detected, dial is not performed.
Default: 0 (NO)
SW7 No.3 Busy tone detection
Used to set whether busy tone signal is detected or not in ringing.
When set to 1, busy tone is detected.
When set to 0, busy tone is not detected.
Default: 1 (Busy tone is detected.)
SW7 No.4 Dial tone monitoring time
Used to set dial tone monitoring time when detecting dial tone.
"1": 10sec
"0": 5sec
Default: 0 (5 sec)
SW7 No.5 Inhibited to use
SW7 No.6 Max. length of reception
Used to set the length of reception when long document is sent from
the other party.
When set to 1, reception is made without limitations.
When set to 0, reception is terminated after 1.5m reception.
Default: 0 (Reception is terminated after receiving 1.5m.)
SW7 No.7, No.8 Modem speed in reception fixed
Used to set the start speed of reception procedure when receiving from
an other party other than V.34.
When set to "no fixing," the operations are the same as V.17-
14400BPS.
The above four setups are possible. The reception procedure is started
at the set communication speed.
Default: 0 0 (no fixing) Reception is made at the proper communica-
tion speed.
SW8 No.1 Memory transmission/direct transmission 
default setup
Used to select memory transmission or direct transmission when the
power is turned on and when time out is cleared.
When set to 1, direct transmission is selected when the power is turned
on and the time out is cleared.
When set to 0, memory transmission is selected when the power is
turned on and the time out is cleared.
Default: 0 (Memory transmission)
bit
7
8
0
0
: No fixing
0
1
: V.29-9600BPS
1
0
: V.27ter-4800BPS
1
1
: V.17-14400BPS
AR-FX4 SOFT SWITCH DESCRIPTIONS - 21
SW8 No.2 Proxy reception
When set to 1, auto reception is accepted under the following condi-
tions to perform proxy reception.
(1) No recording paper or jam
(2) Remaining image memory capacity is 128KB or 64KB or above.
(3) The number of memory reception (max. 50 items) and the number
of pages do not exceed the limit.
When set to 0, automatic reception is not allowed without recording
paper or in case of a jam.
Default: 1 (YES)
SW8 No.3 Printing the content of transmitted document in 
normal memory transmission
Used to set whether transmitted images are printed on the communica-
tion result table or not when the communication result table is printed
after normal completion of memory transmission.
"1": The transmitted document is not printed.
"0": The transmitted document is printed.
Default: 1 (Not printed.)
SW8 No.4 Judgment of system No. in bulletin 
transmission
Used to set whether the condition of coincidence between the system
number of this machine and that of the other party machine is
employed as a criterion to judge whether to allow bulletin transmission
by receiving polling transmission from the other party machine made
by our company.
"1": When the system number of the other party machine made by our
company coincide with the system number of this machine, polling is
allowed.
"0": Though the system number of the other party machine made by
our company coincide with the system number of this machine, polling
is not allowed.
Default: 0 (Inhibited)
SW8 No.5 Remote reception indication
Used to set whether remote select function is used or not.
When set to 1, the function is allowed.
When set to 0, inhibited.
Default: 1 (Allowed)
SW8 No.6 – No.8 Inhibited to use
SW9 No.1 Print of total communication time and total 
pages
Used to set whether total communication time and total number of
sheets are recorded or not on the communication record table.
When set to 1, the total communication time and the total number of
pages are printed on the communication record table.
When set to 0, they are not printed on the communication record table.
Default: 1 (YES)
SW9 No.2 Inhibited to use
SW9 No.3 Quick memory transmission
Used to set whether quick memory transmission (transmission of ring-
ing before completion of scanning) is performed or not. Linked with the
key operator program menu.
Default: 1 (Allow)
SW9 No.4 Yes/No of SUB capacity in reception
Used to set notification of YES/NO of DIS signal Bit 49 SUB capacity.
"0": YES
"1": NO
Default: 0 (YES)
When notified 0 and NO, the F code transmission from the other party
can be inhibited.
SW9 No.5 F-code relay broadcast function
Used to set whether F code relay broadcast instruction from the other
party is received and relay broadcast transmission is performed or F
code relay broadcast instruction is not received (though the relay box
number by SUB coincides with) from the other party. Though this func-
tion is set to disable, F code instruction can be transmitted.
Default: 0 (Allow)
SW9 No.6 F-code confidential reception function
Used to set whether F code confidential reception from the other party
is made or not (though the confidential box number by SUM coincides
with).
Though this function is set to disable, F code transmission can be
made.
Default: 0 (Allow)
SW9 No.7 Yes/No of SEP capacity in reception
Used to set notification of YES/NO of DIS signal Bit 47 SEP capacity.
"0": YES
"1": NO
Default: 0 (YES)
When set to 1 (NO), F code polling is inhibited.
SW9 No.8 Yes/No of reception PWD capacity
Used to set whether password function is judged or not for F code bul-
letin board polling.
"0": Password is judged. If password is not acceptable, communica-
tion is cut off.
"1": Password is not judged. Password is disregarded and communi-
cation is allowed.
Default: 0 (Password is judged.)
SW10 No.1 Measurement of communication time (image)
Used to set YES/NO of measurement.
Used to measure the communication time in phase C. However, it is
the communication time in the latest phase C. (Unit: msec)
Default: 1 (YES)
SW10 No.2 Sender’s telephone number registration
Used to set Enable/Disable of registered transmitter telephone number
change.
When set to 1, sender’s TEL No. cannot be registered and changed.
To prevent sender’s TEL No. from being changed erroneously, this is
set to 1.
Default: 0 (Allow)
SW10 No.3 Yes/No of reception SID capacity
Used to set whether password is judged or nor in F code reception.
"0": Password is judged. If password is not acceptable, communica-
tion is cut off.
"1": Password is not judged. Password is disregarded and communi-
cation is allowed.
Default: 0 (Password is judged.)
SW10 No.4 SDT signal detection
Used to set whether SDT signal which is the second dial tone when
transmitting to F net is detected or not.
When SDT signal is not detected, dialing is performed normally even
after "16X."
When set to 1, the signal is detected.
When set to 0, the signal is not detected.
Default: 0 (Not detected)
SW10 No.5, No.6 Inhibited to use
SW10 No.7 ECM MMR mode
Used to set whether MMR coding system is used or not.
"1": MMR is used.
"0": MMR is not used.
Default: 1 (MMR communication is made.)
Page of 74