Sharp AR-FX4 Service Manual ▷ View online
AR-FX4 INSTALLATION PROCEDURE - 2
6) Attach the fax PWB.
Mount the two spacers on the fax PWB.
Next, insert the fax PWB connector into the connector on the
expansion PWB, install with 4 M3 screws with washer.
expansion PWB, install with 4 M3 screws with washer.
7) Attach the TEL/LIU PWB.
Insert the TEL/LIU PWB connector into the fax PWB connector,
attach 2 spacers on the TEL/LIU PWB, and attach the TEL/LIU
PWB with 2 M3 screws with washer.
attach 2 spacers on the TEL/LIU PWB, and attach the TEL/LIU
PWB with 2 M3 screws with washer.
8) Reattach the left rear cabinet.
1. Pass the speaker harness through the hole of the frame of the
fax expansion PWB and connect it to the connector of the fax
PWB.
PWB.
2. Fit the pawls of the left rear cabinet to the mounting portions of
the main unit. Slide the cabinet toward the front of the main unit
to attach it.
to attach it.
3. Fix the left rear cabinet with 2 screws.
4. Attach the supplied fax connector cover.
9) Reattach the shielding plate.
Fit the pawls of the shielding plate to the main unit and secure the
plate using five screws.
plate using five screws.
Insert the power plug of the copier to the outlet and turn
on the main switch. Then, carry out the following
procedure.
on the main switch. Then, carry out the following
procedure.
10) Date/time setting
Press [SPECIAL FUNCTION] key on the operation panel, select
[KEY OPERATOR PROGRAM]. Input 5-digit Key Operator Code
with 10-key, and select [FAX] in Mode Select.
[KEY OPERATOR PROGRAM]. Input 5-digit Key Operator Code
with 10-key, and select [FAX] in Mode Select.
Select [DEFAULT SETTING], [DATE/TIME SETTING], and input
month/day/year in this order, and press [OK] to set.
month/day/year in this order, and press [OK] to set.
Input hour/minute in this order, and press [OK] to set.
2. Mounting of additional memory
(AR-MM5, MM6, MM7)
• When mounting memory, turn off the main unit.
1) Remove the fax connector cover using a flatblade screwdriver or
the like.
2) Insert the memory card securely so that the model name is on the
rear side.
3) Reattach the fax connector cover.
• Turn on the main unit.
(When turning on the main unit just after expansion, the system
check time will become longer due to memory initialization.)
check time will become longer due to memory initialization.)
4) Make certain that the memory was expanded by displaying SW list
with SIM 66-21.
Spacers
Fax PWB
M3 screws with
washer
washer
M3 screws with
washer
washer
M3 screws with washer
TEL/LIU PWB
Spacers
1
2
3
4
3
Screw
Screw
Speaker harness
Left rear cabinet
Pawls
Fax connector cover
Screws
Shielding plate
Fax connector cover
Memory card
1)
1)
2)
3)
3)
AR-FX4 ADJUSTMENTS - 1
[4] ADJUSTMENTS
1. Density section
A. FAX mode density adjustment (Overall mode)
(<FAX mode> SIM 46-12)
1) Set the test chart (TPAP-2109SCZZ <CCITT #3 chart>) on the OC
table as shown below, and close the OC cover.
2) Switch to the FAX mode and execute SIM 46-12.
3) After warming up, shading is performed and the current density
level is displayed on the lower two digits of the display section in
standard and auto density mode.
standard and auto density mode.
4) Enter the set value with the 10-key to adjust the FAX image den-
sity.
5) Make a copy, and adjust so that the following adjustment specifica-
tion is satisfied.
∗
When an adjustment is made in this mode, the exposure level for
each communication mode and each density mode are automatically
adjusted accordingly.
each communication mode and each density mode are automatically
adjusted accordingly.
<Adjustment specifications>
B. FAX mode density adjustment (Individual mode)
(<FAX mode> SIM 46-13 – 16)
1) Set the test chart (TPAP-2109SCZZ <CCITT #3 chart>) on the OC
table as shown below, and close the OC cover.
2) Switch to the FAX mode and execute SIM 46-13 to 46-16 depend-
ing on the adjustment mode.
3) After warming up, shading is performed and the current density
level is displayed on the lower two digits of the display section.
4) Enter the set value with the 10-key to adjust the FAX image den-
sity.
5) Make a copy, and adjust the density with the copy as a reference.
<Adjustment specifications>
Section
Adjustment items
Adjustment procedures
1
Density section
A
FAX mode density adjustment (Overall mode)
<FAX mode> SIM 46-12
B
FAX mode density adjustment (Individual mode)
<FAX mode> SIM 46-13 – 46-16
2
Communication section
A
Dial test
<FAX mode> SIM 66-13
Density
mode
Resolution
mode
SIM
CCITT #3
chart output
result
Set value
Set
range
Auto
Standard
FAX
mode
46-12
mode
46-12
“3” is slightly
copied.
copied.
The greater the
set value is, the
greater the density
is, and vice versa.
set value is, the
greater the density
is, and vice versa.
0 – 99
Glass holding plate
Resolution
mode
Density
changeover
SIM
Set value
Set
range
Standard
Switched with the
density select
key.
density select
key.
FAX
mode 46-
13
mode 46-
13
The greater the
set value is, the
greater the density
is, and vice versa.
set value is, the
greater the density
is, and vice versa.
0 – 99
Fine
Switched with the
density select
key.
density select
key.
FAX
mode 46-
14
mode 46-
14
Super fine Switched with the
density select
key.
key.
FAX
mode 46-
15
mode 46-
15
Ultra fine
Switched with the
density select
key.
density select
key.
FAX
mode 46-
16
mode 46-
16
Glass holding plate
AR-FX4 ADJUSTMENTS - 2
2. Communication section
Note: These items are factory adjusted when shipping according to
FCC standards. Therefore, do not change the setting in the mar-
ket.
ket.
A. Dial test (<FAX mode> SIM 66-13)
(1) Dial pulse transmission test
1) Execute SIM 66-13 in FAX mode.
2) Execute the dial pulse mode according to the instructions on the
LCD display.
3) Select the dial pulse.
4) Set the make time.
5) Select the dial to be transmitted.
Default: 0123456789
∗
#
(After deleting with the clear key, it can be set to any desired
value.)
value.)
6) Transmission is started from the line.
(2) DTMF signal transmission level adjustment
1) Execute SIM 66-13 in the FAX mode.
2) Execute the DTMF mode according to the instructions on the LCD
display.
3) Select the signal transmission level.
The signal transmission level is classified into two groups: the high
group, and the low group.
group, and the low group.
Transmission can be made with either of default and the soft SW
set value.
set value.
4) The transmission level can be set when the following menu is dis-
played on the LCD. (et value 1 = 0.5dB change)
(This value is returned to the original value when the simulation
mode is canceled.)
mode is canceled.)
5) Select the dial signal to be transmitted.
Default: 0123456789
∗
#
(After deleting with the clear key, it can be set to any desired
value.)
value.)
6) Start transmission from the line.
SELECT SIGNAL
1:PULSE 2:DTMF
SELECT PULSE
1:10PPS 2:20PPS
INPUT MAKE TIME
(0-15) _
SEND yyPPS xxm s
1:YES 2:NO
SENDING yyPPS xxm s
SIM
Soft
SW
Initial
value
value
Set value
Dial
pulse
make
time
pulse
make
time
10
PPS
PPS
FAX
mode
66-13
mode
66-13
SW 67-
1 – 4
1 – 4
40ms
(14)
(14)
SW set value: 0 – 15
Make time: 26 – 41ms
Make time: 26 – 41ms
1ms step
(Binary
input)
(Binary
input)
20
PPS
PPS
SW 67-
5 – 8
5 – 8
0ms
0 fixed
SELECT SIGNAL
1:PULSE 2:DTMF
SELECT HIGH LEVEL
1:DEFAULT 2:SOFT SW.
SELECT LOW LEVEL
1:DEFAULT 2:SOFT SW.
INPUT VALUE
(0-15) _
H:xx L:yy
1:YES 2:NO
xx: High group soft SW set value
yy: Low group soft SW set value
yy: Low group soft SW set value
SENDING DTMF
SIM
Soft
SW
Initial
value
value
Set value
DTMF
trans-
mission
level
trans-
mission
level
High
group
group
(FAX
mode) 66-
13
(Test only)
mode) 66-
13
(Test only)
SW 53-
1 – 4
1 – 4
3.5dB
(7)
(7)
SW set value:
0 – 15
Transmission
level: 0 – 7.5dB
0 – 15
Transmission
level: 0 – 7.5dB
0.5ms
step
(Binary
input)
step
(Binary
input)
Low
group
group
SW 53-
5 – 8
5 – 8
3.5dB
(7)
(7)
AR-FX4 SIMULATION - 1
[5] SIMULATION
1. Entering the simulation mode/cancel of
simulation mode
• Selection of the main code and the sub code is set with the [START]
key.
• There are two or more screens, the adjustment "Current page/Max.
page" is displayed. Press [
↑
] key (previous page) or [
↓
] key to select
a screen.
2. Simulation code list
3. Details
Operation/procedure
Enter the adjustment value and press the [OK] key, and output opera-
tion is performed for 30sec.
tion is performed for 30sec.
The minimum increment is 2V.
The result of (Set value – 199) / 2 is stored in the EEPROM.
When reading a value from the EEPROM, the value of (EEP value *2)
+ 200 is used as the set value.
Therefore, the set value entered must be an even number. If an odd
number is entered the entered odd number + 1 is displayed after
pressing [OK] key.
The result of (Set value – 199) / 2 is stored in the EEPROM.
When reading a value from the EEPROM, the value of (EEP value *2)
+ 200 is used as the set value.
Therefore, the set value entered must be an even number. If an odd
number is entered the entered odd number + 1 is displayed after
pressing [OK] key.
Operation/procedure
Enter the adjustment value and press the [OK] key, and output opera-
tion is performed for 30sec.
tion is performed for 30sec.
The input value is in the increment of –25V.
Procedure
Key operation
1 Simulation mode selection
2 Main code selection
3 Sub code selection
4
Selection of the mode and
item
item
5 Start simulation operation
6
Returns to the sub code
selection.
selection.
Simulation mode clear
Code
Function
Main
Sub
8
13
Used to check and adjust the operation of the
developing bias voltage in FAX mode and the
control circuit.
developing bias voltage in FAX mode and the
control circuit.
14
Used to check and adjust the operation of the main
charger grid voltage (high mode) in FAX mode and
the control circuit.
charger grid voltage (high mode) in FAX mode and
the control circuit.
15
Used to check and adjust the operation of the main
charger grid voltage (low mode) in FAX mode and
the control circuit.
charger grid voltage (low mode) in FAX mode and
the control circuit.
22
11
FAX related counter display
24
10
FAX related counter clear
26
1
Used to set options. (This simulation is used to
make option setting when an option is installed.)
make option setting when an option is installed.)
60
Used to set enable/disable of the FAX mode key
when FAX is not installed. (When FAX is installed,
the FAX mode is enabled regardless of this setup.)
when FAX is not installed. (When FAX is installed,
the FAX mode is enabled regardless of this setup.)
46
12
FAX exposure level adjustment (batch)
13 to
16
FAX exposure level adjustment (individual)
48
8
FAX magnification ratio adjustment (read)
9
FAX magnification ratio adjustment (print)
10
FAX auto reduction magnification ratio (print).
50
8
FAX lead edge adjustment (read)
9
FAX lead edge adjustment (print)
66
1
FAX related soft SW setting
2
Initial set for the value of the FAX soft SW
3
FAX PWB memory check
4
Signal send mode
6
Printing the confidential password
7
Image data print
10
Image data memory clear
11
300bps signals send
13
Send test and adjustment of the dial pulse and
DTMF signal.
DTMF signal.
17
DTMF signal send
21
FAX information print
30
TEL/LIU state change recognition
32
Receive data check
34
Communication time measurement display
#
→
C
INTERRUPT
→
→
INTERRUPT
10-key (Input main code)
→
START
10-key (Input sub code)
→
START
10-key and
↑ ↓
START
OK or
INTERRUPT
CA
66
37
Speaker sound volume adjustment
38
Time setting/check
50
The FAST area of SRAM is cleared.
53
SRAM backup
8
8-13
Purpose
Adjustment/Operation test/check
Function
(Purpose)
(Purpose)
Used to check and adjust the operation of the
developing bias voltage in FAX mode and the control
circuit.
developing bias voltage in FAX mode and the control
circuit.
Section
Image process (Photoconductor/Developping/
Transfer/Cleaning)
Transfer/Cleaning)
Developer/Toner hopper
(Initial screen)
(Executing screen)
Setting range
200-550
Default
426
8-14
Purpose
Adjustment/Operation test/check
Function
(Purpose)
(Purpose)
Used to check and adjust the operation of the main
charger grid voltage (high mode) in FAX mode and the
control circuit.
charger grid voltage (high mode) in FAX mode and the
control circuit.
Section
Image process (Photoconductor/Developping/
Transfer/Cleaning)
Photo conductor
Transfer/Cleaning)
Photo conductor
(Initial screen)
(Executing screen)
Setting range
1-8
Default
5
Code
Function
Main
Sub
Sim8-13 DV BIAS FAX
FAX 426
EXEC [200-550]
4260
Sim8-13 DV BIAS FAX
FAX 426
EXEC
[200-550]
426
Sim8-14 MHV(H) FAX
FAX 5
EXEC [ 1- 8]
5
Sim8-14 MHV(H) FAX
FAX 5
EXEC
[ 1- 8]
5
Click on the first or last page to see other AR-FX4 service manuals if exist.