DOWNLOAD Sharp AR-FX4 Service Manual ↓ Size: 1.65 MB | Pages: 74 in PDF or view online for FREE

Model
AR-FX4
Pages
74
Size
1.65 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / Service Manual
File
ar-fx4.pdf
Date

Sharp AR-FX4 Service Manual ▷ View online

AR-FX4 OUTLINE/SPECIFICATIONS - 3
(14) Finish stamp
(15) Bulletin board, polling transmission functions
6. Reception function system
(1) Reception mode
(2) Zoom reception
(3) Memory reception function
(4) Received data override output
(5) Transfer
(6) Specified number reception
(7) Confidential function
(8) Rotation reception
(9) Division reception
(10) Duplex reception
(11) 2 in 1 reception
(12) Polling (send request)
(13) Turn around transmission
7. Registration system
(1) Number registration
NO
Bulletin board
Bulletin board
YES
Protection 
function
Check by other party’s number
YES
Check by matching of system number (user’s 
own machine), ID number (other party’s 
machine) (between Sharp machines only)
YES
Default setup
Automatic reception (Reception 
state switchable)
Automatic 
reception
Automatic 
reception setup
YES
Number of calls
0 to 9 times (Factory setup 2 
times, variable)
Automatic 
switching of 
Telephone/Fax
NO
Non-call reception
Allowed by setting the number of 
calls to 0.
Manual 
reception
Manual reception 
setup
YES
Setup for switching 
to automatic 
reception
NO
Number of calls to 
switch to automatic 
reception in 
manual reception 
mode
NO
Answering 
machine 
connection
Answering 
connection
NO
Reception mode time switch
NO
Reduction
Reduction to 
regular size
YES (ON/OFF by key operator 
program)
Reduction between 
regular sizes
YES (by print condition setup of 
key operator program)
Enlargement
NO
Proxy reception
Only when output is disabled.
Compulsory memory reception
NO
YES
Transfer destination registration
YES (Registered by key operator 
program)
Transfer procedure
YES (Operated with function 
menu)
Reception of only specified numbers allowed
NO
Reception of specified numbers inhibited
YES
Confidential 
reception
Sender
Sharp machine having 
confidential function only
Confidential box
Registered up to 10 boxes
Confidential box 
name
36 letters
Confidential ID 
code
May be set per confidential box
Paper is outputted by rotating 90 degrees to the set direction of
paper in cassette
Division size
When no paper for reception of long 
document
Division reception setup
YES (by print condition setup of key 
operator program)
NO
NO
Polling
YES
Resolution at send 
request
Variable by soft SW.
Default: fine
NO
Speed 
dialing
Number of items
300 items
Number of digits of 
other party’s 
number
40 digits
Registered name
36 letters
Searched letters
Up to 10 letters
User tag 
classification
NO
International 
communication 
mode setup
YES
Transmission 
method
Speed dialing key + (000 to 299) + 
Start key
Rapid key 
dialing
Number of items
50 items
Number of digits of 
other party’s 
number
40 digits
Registered name
36 letters
Searched letters
Up to half-size 10 letters
User tag 
classification
NO
International 
communication 
mode setup
YES
Transmission 
method
Rapid dialing key (01 – 50)
Group 
dialing
Registered key
Rapid dialing key
Max. number of 
registration per 
group dialing
100 items (The total number of 
registration is 150 items.)
Registerable 
number
Numbers registered to speed 
dialing, rapid dialing, and numbers 
entered with 10-key
Registered name
36 letters
Searched letters
Up to 10 letters
User tag 
classification
NO
Transmission 
method
Rapid dialing key
AR-FX4 OUTLINE/SPECIFICATIONS - 4
(2) Sender registration
(3) Polling (send request), bulletin board (remote 
transmission) allow number registration)
(4) Letter input
(5) Registered data write
(6) Date/time adjustment
(7) Backup
8. Telephone function system
9. Memory system
10. Additional information function for transmission
11. Additional print function when receiving
Program
Number of items
9 items
Registerable item
All items that can be set in 
transmission, except for time 
setup
Registered name
36 letters
Call method
By pressing program key
Change in setup 
after calling
YES
Sender’s name
36 letters, registered with key operator program
Sender’s number
20 digits, registered with key operator program
Send 
request allow 
number
Registration of 
other party to 
which send 
request is made
10 digits, 20 digits, registered by 
key operator program
System 
number
System number 
registration
Up to 1 number, registered in key 
operator program
ID number
ID number 
registration
Up to 10 items in 4 digits. 
Registered by key operator 
program.
Input method
Key entry
YES
Letters allowed 
for input
Half-size 
characters
Alphabet, Numerical figures, 
Special characters, Codes
YES (Service tool. Dial registration can be made with PC.)
Registered by key operator program.
Backup of registration in power 
failure
SRAM used, by built-in battery
Handset
NO
On-hook function
YES
Reserve
NO
Pause
YES (1 to 15sec: Default 2sec, set 
by key operator program)
Telephone transmission in 
power failure
No (However, external telephone 
transmission is allowed.)
Sound 
volume 
adjustment
Call sound 
volume
YES (Set by key operator program to 
Large/Medium/Small/No sound.)
Line monitor 
sound
YES (Set by key operator program to 
Large/Medium/Small/No sound.)
On-hook sound
YES (Set by key operator program to 
Large/Medium/Small.)
Scan end 
sound
YES (Set by soft switch to Large/
Medium/Small/No sound.)
Communication 
end sound
YES (Set by soft switch to Large/
Medium/Small/No sound.)
Tone pulse switch
Cancel tone/pulse switch setup with 
the key operator program, and set 
with the service switch.
External telephone 
connection
YES
Remote 
reception 
switch
YES (Switch number is in 1 digit + 
∗∗
5
∗∗
Memory capacity
Standard
2MB
Option
Up to 8MB (+2MB/+4MB/+8MB)
Memory content 
(transmission 
reservation) 
confirmation
LCD display
YES
Printout
YES
Memory use status
YES (% display)
Document data memory backup 
in power failure
YES (Flash memory)
Page counter
YES
Date printing
YES (Year/month/day, Year 
in 4 digits)
Date/ display 
sequential switch
NO
Cover paper 
function
Cover 
paper 
item
Date
YES
Receiver’s 
name
YES
Receiver’s 
number
YES
Sender’s 
name
YES
Sender’s 
number
YES
Display of 
number of 
documents 
transmitted
YES
Transmission 
message
YES
Print paper 
size
A4 (AB series)
8.5 x 11 (Inch series)
Transmission 
message
Regular message
CONFIDENTIAL/PLS.
DISTRIBUTE/URGENT/
PLS.
CALL BACK/IMPORTANT
User message
NO
Sender print 
function
Sender’s number
20 digits, registered with 
key operator program
Sender’s name
36 letters
Index print
YES (Set by key operator program)
AR-FX4 OUTLINE/SPECIFICATIONS - 5
12. Recording table system
(1) Communication record function
(2) Communication result report function
(3) Report function
(4) Other report list
13. Others
Communication record table size
AB series
A4 (Not output when 
paper greater than 
A4 is not set.)
Inch 
series
Letter (not output if 
size setting is not 
Letter or larger)
Communication record memory 
capacity
50 items in total of transmission 
and reception
Communication 
record table
Number of 
items
Max. 50 items for each of 
transmission and reception 
(Total of transmission and 
reception is up to 50 items.) 
Record table is outputted 
separately. If registration 
exceeds 50, the oldest one is 
deleted.
Time-specified 
output
YES (2 times per day)
Output when 
recording 
memory full
Soft SW provided
Output of 
individual 
department
YES (Communication time of 
each department is outputted as 
department management record 
table.)
Time-specified communication 
table
Common with transmission 
record table
Confidential reception check 
table
YES
Communication 
result table 
(transmission)
YES (Select Always print/in failure of 
transmission/no print. With key operator 
program)
Broadcast 
communication 
report
YES (Select Always print/in failure of 
transmission/no print. With key operator 
program)
Communication 
result table 
(reception)
YES (Select Always print/in failure of 
transmission/no print. With key operator 
program)
Communication 
result table 
(confidential 
reception)
YES (Select Always print no print. With key 
operator program)
Document content 
print in transmission 
error
YES (Some part of the first page is printed: 
ON/OFF setup by key operator program. 
Confidential transmission data are never 
printed.)
Rapid key dialing 
table
YES (Rapid key table)
Speed dialing table
YES (Speed dialing table)
Group table
YES (Group number table
Telephone number 
table
YES (Table of searched letters in rapid key 
dialing, speed dialing, and group dialing in 
alphabetical order)
Transmission 
message list
NO
ID/Senders list
YES
Confidential ID 
table
YES
Soft switch list
YES
Memory image 
deletion table
NO
CSI transmission 
function
CSI transmission
YES
Department 
management
Limitation on users 
in each department
YES
Number of 
departments 
registered
20 items
Charge 
management 
function for each 
department
NO
Operation panel 
display
LCD
19 letters x 5 lines
Automatic booting mode
NO
AR-FX4 INSTALLATION PROCEDURE - 1
[3] INSTALLATION PROCEDURE
1. Install of expansion kit
A. Parts included
B. Installation
Turn off the main switch of the copier and then remove the 
power plug of the copier from the outlet.
1) Remove the fax dummy cover.
Open the front cover of the copier, remove the screw that fixes the
fax dummy cover, and remove the fax dummy cover.
2) Attach the fax key unit.
Connect the flat cable to the fax key unit, attach the fax key unit to
the operation panel, and use the screw to fix it.
Close the front cover of the copier.
3) Remove the shielding plate and the left rear cabinet.
Remove the 5 fixing screws on the shilding plate and take off the
shilding plate with inserting the flatblade screwdriver, etc.
Next, remove the 5 fixing screws on the left rear cabinet, and slide
it backward to remove.
4) Work the left rear cabinet.
Cut and remove the cut-out portion from the left rear cabinet using
a tool such as nippers.
Be careful about the direction of the tool so that the cut surface is
flat.
5) Attach the speaker.
Attach the speaker to the left rear cabinet using supplied two
golden screws (M3).
Fax key unit
Fax PWB
TEL/LIU PWB
Speaker unit
M3 golden screws:
2 pcs.
M3 screws with 
washer: 6 pcs.
PWB spacers: 2 pcs.
Fax connector cover:
1 pcs.
Line cable: 1 pcs.
Line adapter: 1 pcs.
Writing label: 1 sheet
Installation manual: 
1 sheet
Operation manuals: 
2 pcs.
Fax dummy cover
Screw
Front cover
Fax key unit
Screw
Front cover
(1)
(2)
Screws
Screws
Left rear cabinet
Shielding plate
Cut-out portion
M3 golden screws
Page of 74
Display