SW
NO.
Data
NO.
Item
Switch selection and contents of functions
Initial value
User
program
No.
Remark
SW38
1
Pause time
setup
Used to set the pause time. The set range is 1 sec to
15 sec by binary input. When set to 0, it is the same as
2 sec.
2 sec
0
103
When set to
“0000”, set to
“0010”.
2
0
3
1
4
0
5
Reserved
0
6
Reserved
0
7
Transfer
function
Used to set Enable/Disable of transfer of memory
reception image to another FAX when print is inhibited.
Enable
1
109
8
Reserved
0
SW39
1
Auto send call
time setup (T0
timer setup)
Used to set the call time when call does not reach the
other party in auto send mode. The set range is 30 – 60
sec in the increment of 5 sec by binary input of “(5 sec
× N) + 30 sec)”.
“N” can be set in the range of 0 -7. When set to 7 (65
sec), it is the same as setup of 45 sec.
45 sec
0
116
When set to
“111”, set to
“011”.
2
1
3
1
4
Reserved
0
5
Reserved
0
6
Reserved
0
7
Reserved
0
8
Reserved
0
SW40
1
Number of
recall times in
case of an error
Used to set the number of recall times in case of a
communication error.
1 times
0
114
When set to 2
or more times,
set to 1.
2
0
3
0
4
0
5
0
6
0
7
0
8
1
SW41
1
Number of
recall times in
case of busy
state
Used to set the number of recall times in case of busy
state of the other party or when call does not reach the
other party.
2 times
0
112
When it is set
to 15 or more
times, set to 2.
2
0
3
0
4
0
5
0
6
0
7
1
8
0
SW38 Bit No.
1 2 3 4
Set range
1  – 15 sec in the increment of 1
sec (Binary input)
1: Enable
0: Disable
SW39 Bit No.
1 2 3
Set range
30 sec – 60 sec in the increment
of 5 sec (Binary input)
SW40 Bit No. 
1 2 3 4 5 6 7 8
Set range
0  – 1 times (Binary input)
0: Recall inhibited
SW41 Bit No.
1 2 3 4 5 6 7 8
Set range
0  – 14 times (Binary input)
0: Recall inhibited
AR-FX2
6  – 15
SW
NO.
Data
NO.
Item
Switch selection and contents of functions
Initial value
User
program
No.
Remark
SW42
1
Reserved
0
2
Reserved
0
3
Reserved
0
4
Auto select
between
Manual/Auto
reception
Used to set Enable/Disable of auto select between
Manual/Auto reception
Disable
0
5
Call number of
auto select
between
Manual/Auto
reception
Used to set the call number of auto select between
Manual/Auto reception.
9 times
1
When “0000” is
set, the initial
value of “1001”
is set.
When set to 10
or more times,
set to 9. 
6
0
7
0
8
1
SW43
1
DTMF signal
send time
Used to set the DTMF signal send time when sending it.
The set range is 70 – 310 ms by binary input of “10(ms)
×  N”.  “N” can be set in the range of 6 – 31.
110 ms
0
When set to
under  “00101”,
set to “01011”.
2
1
3
0
4
1
5
1
6
Reserved
0
7
Reserved
0
8
Reserved
0
SW44
1
Tone/Pulse
default setup
Used to set the employing line (dial setup). Selection is
available in 10PPS and TONE.
TONE
1
102
When set to
∗1”, set to “10”
2
0
3
TEL line setup
procedure
Setup to display the dial mode setting in the user
program.
1
102
4
Reserved
0
5
Reserved
0
6
Reserved
1
7
Reserved
0
8
Reserved
0
1: Enable
0: Disable
SW42 Bit No
5 6 7 8
Set range
1 – 9 times
SW43 Bit No. 
1 2 3 4 5
Set range
70  – 310 ms
When set to outside of the range:
110 ms in the increment of 10 ms
(Binary input)
SW44 Bit No.
1 2
10 PPS
0 0
TONE
1 0
1: Disable
0: Enable
AR-FX2
6  – 16
SW
NO.
Data
NO.
Item
Switch selection and contents of functions
Initial value
User
program
No.
Remark
SW45
1
Reserved
0
2
Date format of
LCD, report,
and transmitter
record
Used to set the date format of LCD display, report
descriptions, and the transmitter information.
Day/Month/
Year
1
3
0
4
Time format
Used to set the time format of LCD display, report
descriptions, and the transmitter information.
24H
0
5
Reserved
0
6
Reserved
1
7
Reserved
0
8
Reserved
0
SW46
1
Reserved
1
2
Reserved
1
3
Priority in the
day of week
Used to set the recording sequence of the day of month
and the day of week if the date is in the sequence of
day, month, and year (SW 45 No. 2 – No. 3 : 10).
NO
0
4
Reserved
0
5
Daylight saving
time
Used to set Enable/Disable of Daylight saving time.
Enable
1
144
6
Reserved
0
7
Reserved
0
8
Reserved
0
SW47
1
Time
designation 1
(hour) print on
the activity
report
Used to set time designation 1 (hour) to be printed on
the activity report.
00
0
139
When set to 24
– 31, it is set
to  “00”.
2
0
3
0
4
0
5
0
6
Reserved
0
7
Reserved
0
8
Reserved
0
SW48
1
Time
designation 1
(min) print on
the activity
report
Used to set time designation 1 (min) to be printed on the
activity report.
00
0
139
When set to 59
– 63, it is set
to  “00”.
2
0
3
0
4
0
5
0
6
0
7
Reserved
0
8
Reserved
0
SW45 Bit No.
2 3
Year/Month/Day
0 0
Month/Day/Year
0 1
Day/Month/Year
1 0
1: AM/PM
0: 24H
1: YES
0: NO
1: Enable
0: Disable
SW47 Bit No.
1 2 3 4 5
Set range
00  – 23
Input of 2 digits (Binary input)
SW48 Bit No.
1 2 3 4 5 6
Set range
00  – 59
Input of 2 digits (Binary input)
AR-FX2
6  – 17
SW
NO.
Data
NO.
Item
Switch selection and contents of functions
Initial value
User
program
No.
Remark
SW49
1
Time
designation 2
(hour) print on
the activity
report
Used to set time designation 2 (hour) to be printed on
the activity report.
00
0
139
When set to 24
– 31, it is set
to  “00”.
2
0
3
0
4
0
5
0
6
Reserved
0
7
Reserved
0
8
Reserved
0
SW50
1
Time
designation 2
(min) print on
the activity
report
Used to set time designation 2 (min) to be printed on the
activity report.
00
0
139
When set to 59
– 63, it is set
to  “00”.
2
0
3
0
4
0
5
0
6
0
7
Reserved
0
8
Reserved
0
SW51
1
Reserved
0
2
Reserved
0
3
Reserved
0
4
Reserved
0
5
Reserved
0
6
CED detection
time
Used to set CED/ANSam signal detection time. When
the CED/ANSam signal is detected for duration of the set
time, it is recognized.
1000 ms
0
7
Reserved
0
8
Reserved
0
SW52
1
Reserved
0
2
Reserved
0
3
Reserved
0
4
Reserved
0
5
RTN reception
error process
Used to set whether RTN reception is treated as a
communication error or not.
Treated
as an
error
0
6
V.34 mode
function in
manual
communication
Used to set ON/OFF of V.34 mode function on the other
party side in manual communication. If SW52-7 is set to
“0: OFF”, though SW52-6 is set to “1: ON”, V.34 mode is
disabled.
ON
1
7
V.34 mode
function
Used to set ON/OFF of V.34 mode function on the
machine.
ON
1
8
V.34 control
channel
communication
speed
Used to set V.34 mode communication speed of the
control channel. If the other party is not set to 2400 bps
Enable, it is set to 1200 bps.
1200 bps
0
SW47 Bit No.
1 2 3 4 5
Set range
00  – 23
Input of 2 digits (Binary input)
SW48 Bit No.
1 2 3 4 5 6
Set range
00  – 59
Input of 2 digits (Binary input)
1: 500 ms
0: 1000 ms
1: Not treated as an error
0: Treated as an error
1: ON
0: OFF
1: ON
0: OFF
1: 2400 bps
0: 1200 bps