Sharp AR-FX2 (serv.man2) Service Manual ▷ View online
SW
NO.
Data
NO.
Item
Switch selection and contents of functions
Initial value
User
program
No.
Remark
SW25
1
Auto reduction
ratio setup
ratio setup
Used to set the auto reduction ratio when “Auto
reduction print” is set to Enable. The set value is the
min. reduction ratio.
reduction print” is set to Enable. The set value is the
min. reduction ratio.
10%
1
2
0
3
1
4
0
5
Reserved
0
6
Reserved
0
7
Reserved
0
8
Reserved
0
SW26
1
Read end
sound
sound
Used to set whether read end sound is made or not
when read is completed. For manual transmission and
direct transmission, no sound is made.
when read is completed. For manual transmission and
direct transmission, no sound is made.
1 sec
0
2
Reserved
0
3
Speaker sound
volume setup
volume setup
Used to set speaker sound volume. The following items
of sound volume setup are the same as this setup: Line
monitor sound volume, operation panel sound volume,
send end sound volume, receive end sound volume,
read end sound volume.
of sound volume setup are the same as this setup: Line
monitor sound volume, operation panel sound volume,
send end sound volume, receive end sound volume,
read end sound volume.
Small
0
104
Each sound
volume can be
turned OFF
individually.
When this is
set to OFF, all
the items on
the left are
turned OFF.
volume can be
turned OFF
individually.
When this is
set to OFF, all
the items on
the left are
turned OFF.
4
1
5
Reserved
0
6
Reserved
0
7
Reserved
0
8
Reserved
0
SW27
1
Reserved
0
2
Recording
paper tray
select
paper tray
select
Used to select the tray for output of the received
documents. Tray 1 – Tray 4 can be set to ON/OFF
individually. When set to OFF, the tray does not output
received documents.
documents. Tray 1 – Tray 4 can be set to ON/OFF
individually. When set to OFF, the tray does not output
received documents.
ON
1
134
When set to
“0000”, set to
“1111” (All ON).
“0000”, set to
“1111” (All ON).
3
ON
1
4
ON
1
5
ON
1
6
Reserved
0
7
Reserved
0
8
Reserved
0
SW25 Bit No.
1 2 3 4
Set range
0 – 15% (Binary input)
1: Silent
0: 1 sec
SW26 Bit No.
3 4
Silent (OFF)
0 0
Small
0 1
Medium
1 0
Large
1 1
SW27 Bit No. 2
Tray 1
1: ON
0: OFF
SW27 Bit No. 3
Tray 2
1: ON
0: OFF
SW27 Bit No. 4
Tray 3
1: ON
0: OFF
SW27 Bit No. 5
Tray 4
1: ON
0: OFF
AR-FX2
6 – 11
SW
NO.
Data
NO.
Item
Switch selection and contents of functions
Initial value
User
program
No.
Remark
SW28
1
Reserved
1
2
Reserved
0
3
Reserved
0
4
Reserved
0
5
Reserved
0
6
Reserved
0
7
Reserved
0
8
Standard
reading setup
reading setup
Read mode setup in the standard mode
Reading
Fine
mode
Fine
mode
0
SW29
1
Reserved
0
2
Reserved
0
3
Reserved
0
4
Reserved
0
5
Number of call
rings
rings
Used to set the number of call rings until reception is
started in auto reception mode. The set range is 0 – 9
times by binary input. When set to 0, no ring is made.
started in auto reception mode. The set range is 0 – 9
times by binary input. When set to 0, no ring is made.
2 times
0
117
When set to 10
or more times,
set to 2.
or more times,
set to 2.
6
0
7
1
8
0
SW30
1
Report output
when canceling
when canceling
Used to set whether the user cancel report is outputted
or not when canceling document transmission.
or not when canceling document transmission.
Not output
0
2
Reserved
0
3
Rotation print
Used to set Enable/Disable of rotation print when the
received document can be printed by rotation.
received document can be printed by rotation.
Enable
1
4
Dept.
management
management
Used to set Enable/Disable of FAX using dept.
management by the use of the dept. management
function.
management by the use of the dept. management
function.
Disable
0
101
If the dept.
code is not set,
Enable cannot
be selected.
code is not set,
Enable cannot
be selected.
5
Default date,
transmitter print
transmitter print
Used to set whether the transmitter information registered
in the transmitter registration and data and time are
printed in the upper fringe of the transmitted documents
or not.
in the transmitter registration and data and time are
printed in the upper fringe of the transmitted documents
or not.
ON
1
6
Reserved
0
7
Date/Transmitter
print position
setup
print position
setup
Used to set the print position of date and transmitter
information on the transmitted documents. If set to
“Upper inside of document”, images may be deleted.
information on the transmitted documents. If set to
“Upper inside of document”, images may be deleted.
Outside
of
document
of
document
0
140
8
Report output
(Confidential
reception)
(Confidential
reception)
Used to set whether the communication report table is
outputted or not when a confidential reception is made.
outputted or not when a confidential reception is made.
Print
1
1: cm50% (Standard
mode is read as
Standard mode.)
mode is read as
Standard mode.)
0: Without cm50%
(Standard mode is read
as Fine mode.)
(Standard mode is read
as Fine mode.)
SW29 Bit No.
5 6 7 8
Set range
0 – 9 times (Binary input)
1: Output
0: Not output
1: Enable
0: Disable
1: Enable
0: Disable
1: ON
0: OFF
1: Upper inside of
document
document
0: Outside of document
1: Print
0: Not print
AR-FX2
6 – 12
SW
NO.
Data
NO.
Item
Switch selection and contents of functions
Initial value
User
program
No.
Remark
SW31
1
Report output
(Transmission)
(Transmission)
Used to set whether the communication report is
outputted or not after completion of transmission
(excluding sequential broadcasting, sequential send
request, and interface broadcasting).
outputted or not after completion of transmission
(excluding sequential broadcasting, sequential send
request, and interface broadcasting).
Only
when
transmis-
sion is
cancelled
when
transmis-
sion is
cancelled
1
137
When set to
“11”, set to “10”
(Only when
transmission
cannot be
made)
“11”, set to “10”
(Only when
transmission
cannot be
made)
2
0
3
Report output
(Sequential
broadcasting,
sequential
send request,
interface
broadcasting)
(Sequential
broadcasting,
sequential
send request,
interface
broadcasting)
Used to set whether the communication report table is
outputted or not after completion of transmission
(sequential broadcasting, sequential send request, and
interface broadcasting).
outputted or not after completion of transmission
(sequential broadcasting, sequential send request, and
interface broadcasting).
All print
0
137
When set to
“11”, set to “01”
(All print).
“11”, set to “01”
(All print).
4
1
5
Report output
(Reception)
(Reception)
Used to set whether the communication report table is
outputted or not when a reception (excluding confidential
reception) is made.
outputted or not when a reception (excluding confidential
reception) is made.
Print
inhibited
inhibited
0
137
When set to
“11”, set to “00”
(Print inhibited).
“11”, set to “00”
(Print inhibited).
6
0
7
Reserved
0
8
Reserved
0
SW32
1
Distinctive ring
Used to set the ring pattern of FAX reception.
Only
Australia
Australia
0
110
When a bit
other than the
specified on
the left is set,
the initial value
“0000(OFF)” is
set.
other than the
specified on
the left is set,
the initial value
“0000(OFF)” is
set.
2
0
3
0
4
0
5
Reserved
0
6
Index print
setup
setup
Used to set whether the index is printed or not when
outputting received documents.
outputting received documents.
Not print
0
142
7
Reserved
0
8
Reserved
0
SW33
1
Page number
print setup
print setup
Used to set whether the page number is added to the
position where date and transmitter information are
printed. (In memory transmission, paper number/total
number of pages)
position where date and transmitter information are
printed. (In memory transmission, paper number/total
number of pages)
YES
1
141
2
Reserved
0
3
Reserved
0
4
Reserved
0
5
Reserved
0
6
Reserved
0
7
Reserved
0
8
Reserved
0
SW31 Bit No.
1 2
Print inhibited
0 0
All print
0 1
Only when transmission is cancelled
1 0
SW31 Bit No.
3 4
Print inhibited
0 0
All print
0 1
Only the addressee to which a transmission
is canceled
is canceled
1 0
SW31 Bit No.
5 6
Print inhibited
0 0
All print
0 1
Only in case of an error
1 0
SW32 Bit No.
1 2 3 4
OFF
0 0 0 0
Standard Ring
0 0 0 1
1: Print
0: Not print
1: YES
0: NO
AR-FX2
6 – 13
SW
NO.
Data
NO.
Item
Switch selection and contents of functions
Initial value
User
program
No.
Remark
SW34
1
Reserved
0
2
Reserved
0
3
Reserved
0
4
Reserved
0
5
Reserved
0
6
Reserved
0
7
Reserved
0
8
Reserved
0
SW35
1
Cover paper
function default
setup
function default
setup
Used to set the cover paper setup to the default. When
auto clear is made after pressing the C/A key, the
machine returns to this mode.
auto clear is made after pressing the C/A key, the
machine returns to this mode.
NO
0
2
Reserved
0
3
CI signal
extinction max.
OFF time
extinction max.
OFF time
If the next CI signal pulse is not detected within the
max. wait time until the next CI signal pulse is detected
after detection of a CI signal pulse (number of times),
the number of calls up to that time is canceled.
max. wait time until the next CI signal pulse is detected
after detection of a CI signal pulse (number of times),
the number of calls up to that time is canceled.
Australia:
5 sec
Europe:
10 sec
5 sec
Europe:
10 sec
0
4
0
5
Reserved
1
6
Reserved
0
7
Reserved
1
8
Reserved
0
SW36
1
Reserved
0
2
Reserved
0
3
Reserved
1
4
Reserved
1
5
Reserved
1
6
Reserved
1
7
Reserved
0
8
Reserved
0
SW37
1
Reserved
0
2
Reserved
0
3
Reserved
0
4
Reserved
0
5
Reserved
0
6
Reserved
1
7
Reserved
0
8
Reserved
1
1: YES
0: NO
SW35 Bit No.
3 4
5 sec
0 0
10 sec
0 1
15 sec
1 0
20 sec
1 1
AR-FX2
6 – 14