DOWNLOAD Sharp AR-FX2 (serv.man2) Service Manual ↓ Size: 1.99 MB | Pages: 59 in PDF or view online for FREE

Model
AR-FX2 (serv.man2)
Pages
59
Size
1.99 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / AR-FX2-Service Manual
File
ar-fx2-sm2.pdf
Date

Sharp AR-FX2 (serv.man2) Service Manual ▷ View online

66
04
● The following signals are sent to the line and the main body speaker.
● The send signals are as follows:
01: No signal is sent.
26: 7eH flag signal
27, 28, 30: Tone signal
31: Pseudo ringer sound (With the On-hook key pressed)
32: Voice message silent <Not used>
33: Ring back tone silent <Not used>
34: Dial pulse make
Under the state where dial pulses can be sent to the line, the make state is
kept.
35: Dial pulse break
Under the state where dial pulses can be sent to the line, the break state is
kept.
Other than the above: FFH
● The signal send level is selectable between 0db or the soft SW set value.
Since, however this setup is not required for pseudo ringer sound, voice
message (silent), ring back tone (silent), and dial pulse make/break., the
selection menu does not appear. (For 01, 31 to 35,  selection between 0db and
the soft SW set value cannot be made.)
● Signal send is continued until an interruption command is outputted.
● The signal send level is returned to the soft SW set value before execution of
this mode when this mode is terminated.
06
Confidential
communication
password print
Used to print the currently set confidential communication password.
07
Image memory content
output
Used to print all image data stored in the image memory. The following
image data are also outputted.
● Image data received in a  confidential communication remote send image data
read in the memory
Note: Image data are cleared after being outputted.
08
Voice message send
<Not used>
Used to send the voice reply message.
10
Image memory clear
Used to clear all data stored in the image memory.
The following data are also cleared.
• Image data received in confidential communication
• The management table is also initialized.
Display/Key operation
<Signal send level>
0db: Signals are
sent in 0db.
Soft SW: Signals
are sent in the
level set with the
soft SW.
<Send signals>
01: No signal (CMLON)
02: 33600bps (V34)
03: 31200bps (V34)
04: 28800bps (V34)
05: 26400bps (V34)
06: 24000bps (V34)
07: 21600bps (V34)
08: 19200bps (V34)
09: 16800bps (V34)
10: 14400bps (V34)
11: 12000bps (V34)
12: 9600bps (V34)
13: 7200bps (V34)
14: 4800bps (V34)
15: 2400bps (V33)
16: 14400bos (V33)
17: 12000bps (V33)
18: 14400bps (V17)
19: 12000bps (V17)
20: 9600bps (V17)
21: 7200bps (V17)
22: 9600bps (V29)
23: 7200bps (V29)
24: 4800bps (V27ter)
25: 2400bps (V27ter)
26: 300bps (FLAG)
27: 2100Hz (CED)
28: 1100Hz (CNG)
29: 300bps (V21)
30: 2100Hz (ANSam)
31: Pseudo ring sound
32: Voice message silent
33: Ring back tone silent
34: Dial pulse make
35: Dial pulse break
<Sound volume setup>
LARGE: Signals are sent
in the LARGE sound
volume level.
Soft SW: Signals are sent
in the level set with the
soft switch 70-1.
<Message>
1:  “Wait for a moment.”
2:  “No one is around the phone. For
FAX send, please press the START button.
(FAX/TEL reply message)
3: Reserved sound
AR-FX2
5  –  4
66
11
300bps signal send
Used to send signals in 300bps.
13
Dial test
Used to check dial pulses (10PPS), check the DTMF signal send, adjust the
dial pulse make time, and adjust the DTMF signal send level. For adjustment
procedures, refer to the previous descriptions.
17
DTMF signal send
Used to send the DTMF signal. When another dial number is pressed during
DTMF signal send, the DTMF signal corresponding to the pressed dial
number is sent.
22
Handset sound volume
adjustment
<Not used>
Used to set the handset sound volume.
30
TEL/LIU status change
check
Used to display the following status change of TEL/LIU.
• Polarity reverse relay
• External telephone hook switch relay
32
Reception data check
Used to check the fixed data received from the line. Since a nit to send the
fixed data is required, this mode is not required in this market.
34
Communication time
measurement display
Used to make transmission and reception tests, measure the time required
for transmission (reception) of image data in the communication, and inform
of it.
• Measurement range
Transmission: From sending of the flag signal before sending of the image
data to sending of RCP frame.
Reception: From reception of the flag signal before reception of the image
data to reception of RCP frame.
The communication test is performed in the standard display. After
completion of communication, the time measured in this mode is checked.
• The setup items in transmission are as follows:
• Communication means: memory transmission
• Image quality: Standard
• Density: Light
ECM: ON
Transmitter record: OFF
37
Speaker sound volume
adjustment
Used to set the speaker sound volume.
38
Time setup/check
Used to display and correct the time (year, month, day, day of week, hour,
minute) installed in the FAX PWB.
Display/Key operation
<Signal send level>
0db: Signals are sent in 0db.
Soft SW: Signals are sent in the
level set with the soft switch.
<Signal pattern>
1: No signal
2: 111111
3: 111110
4: 000000
5: 010101
6: 000001
<Signals>
Dial pulse (10PPS)
DTMF signal
Display/Key operation
<Signal send level>
0db: Signals are sent in 0db.
Soft SW: Signals are sent in the
level set with the soft switch.
<Send dial number>
10-key
Key operation
1: Small
2: Large
Display
Signal
LOW
HIGH
HS1
HS2
EXHS
ON
ON
ON
OFF
OFF
OFF
Key operation
0: No sound
1: Small
2: Medium
3: Large
AR-FX2
5  –  5
[6] SOFTWARE SWITCH DESCRIPTIONS
1. Software switch changing procedure
1) Execute SIM 66-01 in the FAX mode.
2) Select “1.YES” in the FAX soft SW setup. 
3) FAX soft SW No. input
XX (2 digits: 10-keyinput) + START key
4) Select “1.YES” in the Soft SW content check.
5) Press the bit No. to be changed, and the bit No. is high-
lighted. 
6) Select “1.YES” in the confirmation menu of change. 
7) The change is completed, and the display returns to the soft
SW select menu.
2. Details
When a value which is outside of the specified range is entered, the
item is automatically set to the default.
Never change the switches which are “Reserved”.
SW
NO.
Data
NO.
Item
Switch selection and contents of functions
Initial value
User
program
No.
Remark
SW1
1
Image quality
priority selection
Used to select the image quality setup (LED) among
“Ultra fine”, “Super fine”, “Fine”, and “Standard” after
pressing C/A key or in auto clear procedure
Standard
0
151
2
0
3
Reserved
0
4
Auto/manual
default setup
Used to select Auto/Manual reception mode when turning
on the power. (When no external telephone is connected,
do not select Manual. However, setup is possible and
reception can be made by on-hook.
Auto
reception
0
Manual can be
set only when
an external
telephone is
connected.
5
Send request
protection
Used to set enable/disable of the confidential function
(inhibition against erroneous transmission) during send
request communication (remote transmission).The
confidential function is performed with identification of the
code numbers which is registered in the machine and
the other party machine. Sender No. 
←  → Send request
allow No. or system No. 
←  → ID No.
Protected
0
118
6
Reduction
send mode
Used to set whether the transmitted document is
received in reduction size or both ends of recording
paper are cut when the transmitted document width is
greater than the recording paper width.
Reduction
0
124
7
Sent document
print in
memory send
error
Used to set Print/Not print part of the sent document in
the transmission result table in case of a memory
transmission error. For confidential transmission,
however, no output is made.
Print
0
138
8
Reserved
0
SW1 Bit No.
1 2
Standard
0 0
Fine
0 1
Super fine
1 0
Ultra fine
1 1
1: Manual reception
0: Auto reception
1: Not protected
0: Protected
1: Standard
0: Reduction
1: Not print
0: Print
AR-FX2
6 – 1
SW
NO.
Data
NO.
Item
Switch selection and contents of functions
Initial value
User
program
No.
Remark
SW2
1
Reserved
0
2
Reserved
0
3
Reserved
0
4
Reserved
0
5
Remote select
No. setup
Used to set the number for remote select reception from
an external telephone with binary input. However, the
remote select numbers “x
∗∗” and “∗” are fixed.
For an input over “10”, the same operation as the initial
value of “5” is performed.
5
0
108
When a value
in the range of
10  – 15 is set,
set to “5.”
6
1
7
0
8
1
SW3
1
Density default
setup
Used to set the density (LED) after pressing C/A key or
in auto clear operation to Auto, Light, Slightly light,
Medium, Slightly data, and Dark.
Auto
0
153
2
0
3
0
4
0
5
0
6
Reserved
0
7
Size
specification
Used to set the source of judgement of size specification
(AB series or inch series).
Follows
the
machine
informa-
tion.
If the machine
information is
uncertain when
set to “Follows
the machine
information”,
the metric size
is effective.
8
1
SW4
1
Recall interval
in case of a
communication
error
Used to set recall interval after disconnection of
communication due to a communication error in memory
transmission. The set range is 0 to 15 min in the
increment of 1 min by binary input. When set to 0, recall
is made immediately after disconnection. However, the
time interval set by SW21 (Interval between the end of a
communication and the next call) is taken.
1 min
0
113
0: Immediate
recall after
disconnection.
2
0
3
0
4
1
5
Recall interval
in case of
busy state
Used to set recall interval after disconnection of
communication due to the busy state of the other party
or no response. The set range is 0 to 15 min in the
increment of 1 min by binary input. When set to 0, recall
is made after 3 min.
3 min
0
111
When “0000” is
tried to be set,
“0011” is set.
6
0
7
1
8
1
SW2 Bit No.
1 2 3 4 5 6 7 8
Set range
0 – 9 (Binary input)
SW Bit No.
1 2 3 4 5
Auto
0 0 0 0 0
Light
1 0 0 0 0
Slightly light
0 1 0 0 0
Medium
0 0 1 0 0
Slightly dark
0 0 0 1 0
Dark
0 0 0 0 1
SW Bit No.
7 8
AB series
0 0
Inch size
1 0
Follows the machine
information.
0 1
Follows the machine
information.
1 1
SW4 Bit No.
1 2 3 4
Set value
0  – 15 (Binary
input)
SW4 Bit No.
5 6 7 8
Set value
0 – 15 (Binary input)
AR-FX2
6  –  2
Page of 59
Display