Sharp AR-C262M (serv.man3) Service Manual ▷ View online
AR-C262M SPECIFICATIONS 3 - 8
(2) PULL SCAN (NETWORK TWAIN)
Once the network Twain Driver has installed onto PC, user can
made pull scan with TWAIN-support application.
made pull scan with TWAIN-support application.
For making pull type scan, the product key entry (release the func-
tion) and installation of the additional 256MB memory for each
Printer and ICU/NIC/HDD are required. The network TWAIN driver
is planned to be delivered with Whale-II base unit.
tion) and installation of the additional 256MB memory for each
Printer and ICU/NIC/HDD are required. The network TWAIN driver
is planned to be delivered with Whale-II base unit.
Note that user cannot make pull scan only with this driver.
a. Operation flow (PULL SCAN)
1. Press [IMAGE SEND] on the operation panel to obtain the ini-
tial screen in image send mode.
2. Press [REMOTE PC SCAN] displayed at center of the screen.
3. Set original onto document glass or RADF.
4. Boot TWAIN scan from TWAIN-support application. (It must be
previously installed.)
5. Whale-II network Twain driver boots.
6. User can preview the image by PREVIEW and can retrieve the
image by SCAN.
b. Basic operations (PUSH SCAN)
Document
Document type/ Image
quality type
quality type
Text
Text/Printed Photo
Text/Photograph
Printed Photo
Text/Printed Photo
Text/Photograph
Printed Photo
∗
Photograph
∗
Map
∗
∗
: Only in manual density adjustment
(The default: Text mode/Automatic)
File format
B/W (1bit)
TIFF-Non compression (Multi page allowed)
TIFF-G3-1dim (Multi page allowed)
TIFF-G4 (Multi page allowed)
PDF-Non compression (Multi page allowed)
PDF-G3-1dim (Multi page allowed)
PDF-G4 (Multi page allowed)
TIFF-G3-1dim (Multi page allowed)
TIFF-G4 (Multi page allowed)
PDF-Non compression (Multi page allowed)
PDF-G3-1dim (Multi page allowed)
PDF-G4 (Multi page allowed)
Color (RGB x 8bits)
PDF-JPEG High compression (Multi page allowed)
PDF-JPEG Medium compression (Multi page allowed)
PDF-JPEG Low compression (Multi page allowed)
JPEG High compression (Multi page inhibited)
JPEG Medium compression (Multi page inhibited)
JPEG Low compression (Multi page inhibited)
"Multi page inhibited" means images on two or more pages cannot be sent as one
file.
A file is made for each image.
PDF-JPEG Medium compression (Multi page allowed)
PDF-JPEG Low compression (Multi page allowed)
JPEG High compression (Multi page inhibited)
JPEG Medium compression (Multi page inhibited)
JPEG Low compression (Multi page inhibited)
"Multi page inhibited" means images on two or more pages cannot be sent as one
file.
A file is made for each image.
Filed by each page
ON / OFF
(In JPEG, fixed to ON.)
(In JPEG, fixed to ON.)
Maximumsize of E-Mail Attachements
User can set a specified size via the key operator programs. User can select whether
he/she stops and cancels the scan job or sends pages completely scanned, when
the size exceeds the specified size.
he/she stops and cancels the scan job or sends pages completely scanned, when
the size exceeds the specified size.
OC multi scan
Documents of two or more pages can be set as one file from the platen. (Excluding
JPEG format)
JPEG format)
Job contention
During printing, scanning is inhibited.
During scanning, printing is inhibited.
Job history
The job history is not recorded.
Utility
Sharpdesk V3.0 or later
LDAP
Yes
JOB restriction
The scanner mode is disabled during printing. After completion of a print job, it is
enabled. (Print controller restriction)
enabled. (Print controller restriction)
User Authentication
Yes
POP before SMTP
Yes
Address Book Non Anonymous for NST
Yes
Basic spec
Supported OS
Win95/98/Me/NT4.0(Service Pack3 or better)/ 2000/XP
Windows NT 4.0 Terminal Server is not supported.
Administrator authentication is required to use it on Windows NT 4.0, Windows2003
server
Windows NT 4.0 Terminal Server is not supported.
Administrator authentication is required to use it on Windows NT 4.0, Windows2003
server
WHQL Certification
Windows2000 Windows XP, Windows2003 server
Hardware environment
(PC)
(PC)
(System)
Basically, the system must meet the condition of OS operation. (HDD)
8MB or more: 100MB or more is recommended.
(Monitor)
800 x 600 dots or better (256 colors or higher)
(Other)
Network Port
(Scanner cannot be used via the USB port.)
Basically, the system must meet the condition of OS operation. (HDD)
8MB or more: 100MB or more is recommended.
(Monitor)
800 x 600 dots or better (256 colors or higher)
(Other)
Network Port
(Scanner cannot be used via the USB port.)
Language
English, English (American), German, French, Spanish, Swedish, Italian, Dutch, Nordic,
Finish, Danish, Chinese (simplified), Chinese (complained), Japanese
Finish, Danish, Chinese (simplified), Chinese (complained), Japanese
AR-C262M SPECIFICATIONS 3 - 9
Basic spec
Supported application (PC) Photoshop 4.x, 5.x, 6.0, 7.0
imaging
Sharp desk
MS office 2000,XP
Acrobat 5.0
Corel Photo Paint 10
Photo Draw 2000
Picture Publisher 8
PAPERPORT Ver3.0
Sharp desk
MS office 2000,XP
Acrobat 5.0
Corel Photo Paint 10
Photo Draw 2000
Picture Publisher 8
PAPERPORT Ver3.0
Basic setting
Color mode
Options for color mode are
shown left. They are
displayed in a pull down list
to be selected.
Options for color mode are
shown left. They are
displayed in a pull down list
to be selected.
B/W: Simple Binary
B/W: Error diffusion
Gray scale
Full color
• Default: full color
B/W: Error diffusion
Gray scale
Full color
• Default: full color
Resolution
Options (dpi) for resolution
are shown left.
They are displayed in a pull
down list to be selected.
Options (dpi) for resolution
are shown left.
They are displayed in a pull
down list to be selected.
75, 100, 150, 200, 300, 400, 600 dpi (Resolution set on the main unit)
Between 50 and 9600dpi (Resolution available forbeing set via the TWAIN driver.)
• Default: 150dpi
Between 50 and 9600dpi (Resolution available forbeing set via the TWAIN driver.)
• Default: 150dpi
Gradation
RGB x 8bit (256-level)
Scan area
Options for san area are
shown left. They are
displayed in a pull down list
to be selected.
Options for san area are
shown left. They are
displayed in a pull down list
to be selected.
A3, A4, A5, B4, B5, A4R, A5R, B5R, A6R
Ledger, Letter, Legal Executive, Invoice, Foolscap Letter R, Invoice-R,8K, 16K, 16KR
Custom setting
• Default: Custom setting
Ledger, Letter, Legal Executive, Invoice, Foolscap Letter R, Invoice-R,8K, 16K, 16KR
Custom setting
• Default: Custom setting
Zoom
Zoom range: between 25 and 400% in 1 % steps for image enlargement and reduction.
The setting value is set via direct key entry or by pressing up/down arrow keys.
• Default: 100%
The setting value is set via direct key entry or by pressing up/down arrow keys.
• Default: 100%
Note: As result, if the resolution is higher than 600dpi or lower than 75 dpi, zoom is
made by software process.
(Note): Zoom is performed using the software process by changing the resolution level.
Slide bar for brightness
and contrast setting / value
entry box
and contrast setting / value
entry box
User can change the brightness / contrast setting.
• Setting range: between –100 and +100
• Setting range: between –100 and +100
Auto adjust box for input/
output level
output level
When the button is pushed, all levels for image brightness, contrast and input/output
level are automatically adjusted.
• When each of brightness and contrast settings has been made, the value entry box is
level are automatically adjusted.
• When each of brightness and contrast settings has been made, the value entry box is
invalid.
When the “mono binary” has been selected, the box is invalid.
Image quality adjust Threshold
Threshold range for mono: from 1 to 254
Setting is made via slide bar or entering value
• Default: 128
Setting is made via slide bar or entering value
• Default: 128
• Threshold is valid only when the “mono: simplebinary” is selected.
Gamma Adjustment
User can adjust the gamma curve by the gamma setting or free curve (input/output
curve).
The range of the gamma setting is between 0.10 and 9.99 and the standard is 1.0.
curve).
The range of the gamma setting is between 0.10 and 9.99 and the standard is 1.0.
Auto Threshold adjustment Click this key to make pre-scan for threshold adjustment. After making pre-scan, most
appropriate value is set for the threshold.
• This function is invalid when “mono binary” is invalid.
• This function is invalid when “mono binary” is invalid.
B/W reverse
When it is checked, the engine makes black and white gradation reverse.
• Default: not checked
• Default: not checked
B/W reverse is valid, only when either “mono: binary” or “B/W: error diffusion” is
selected.
selected.
Edge emphasis
User can select an image
process method for edge
via pull down list.
User can select an image
process method for edge
via pull down list.
None, Normal, Sharp, Soft
• Default: Normal
• Default: Normal
Edge emphasis is invalid when either “mono: binary” or “B/W: error diffusion” is selected.
Color matching
User can select a color
matching method via pull
down list.
User can select a color
matching method via pull
down list.
None, Printer, CRT, LCD, ICM
• Default: Printer
• Default: Printer
Color matching is invalid when “mono: binary” is valid.
AR-C262M SPECIFICATIONS 3 - 10
(3) Scanner function memory restriction matrix
∗
: Expansion memory must be installed to both of the Copier ICU and the Printer boar.
C. Reversing automatic document feeder
Network scan
specifications
specifications
ICU PWB
Combination
Standard
Expansion-1
Expansion-2
Standard (Slot 1)
256 MB
256 MB
256 MB
Expansion memory
(Slot 2)
—
128 MB
256 MB
Total memory capacity
256 MB
384 MB
512 MB
Printer
controller
PWB
Combination
Standard
Expansion-1
Expansion-2
Expansion-3 Expansion-4
Standard (Onboard)
128 MB
128 MB
128 MB
128 MB
128 MB
Expansion memory
(Slot 1)
—
128 MB
256 MB
256MB
256 MB
Expansion memory
(Slot 2)
—
—
—
128MB
256 MB
Total memory capacity
128 MB
256 MB
384 MB
512 MB
640 MB
PUSH scan
Trial
mode
Color
❍
150dpi or less
Monochrome
❍
200dpi or less
Normal
mode
(Option)
Color
✕
✕
❍
300dpi or less
❍
(
∗
)
600dpi or less
Monochrome
✕
✕
❍
600dpi or less
PULL scan
Normal
mode
(Option)
—
✕
✕
✕
❍
(
∗
)
Type
RADF
(Reversing automatic document feeder)
(Reversing automatic document feeder)
Document set
direction
direction
Face up reference
Document
reference position
reference position
Center reference
Document paper
feed reference
feed reference
Upper take-up reference (1 to N paper feed
reference)
reference)
Document
transport system
transport system
Belt transfer system
Kinds of out-of-
specification
documents
specification
documents
Continuous forms, Thermal paper, Folded
paper, pre-punch paper
paper, pre-punch paper
Document load
capacity
capacity
100 sheets (A4/8.5” x11” or smaller and
80g/m
80g/m
2
(21lbs))
(For paper heavier than 80g/m
2
, the max.
height of original stack is restricted to 10 mm.)
60 sheets (B4/8.5” x13”/8.5” x14” or larger
and 80g/m
60 sheets (B4/8.5” x13”/8.5” x14” or larger
and 80g/m
2
(21lbs))
(For paper heavier than 80g/m2, the max.
height of original stack is restricted to 6 mm.)
height of original stack is restricted to 6 mm.)
Document
detection Yes/No
detection Yes/No
Yes (Size detection on the document tray,
traveling detection)
traveling detection)
Detection size
AB-1
A3, B4, A4, A4R, B5, B5R, A5,
8.5” x 11”, 8.5” x 14”, 11” x 17”
8.5” x 11”, 8.5” x 14”, 11” x 17”
AB-2
A3, B4, A4, A4R, B5, B5R, A5,
8.5” x 11”, 8.5” x 13”, 11” x 17”
8.5” x 11”, 8.5” x 13”, 11” x 17”
AB-3
A3, B4, A4, A4R, B5, 8K, 16K, 16KR,
8.5” x 13”
8.5” x 13”
Inch-1 11" x 17", 8.5" x 14", 8.5" x 11",
8.5" x 11"R, 8.5" x 5.5"
A3, B4, A4, B5, B5R
A3, B4, A4, B5, B5R
Inch-2 11" x 17", 8.5" x 13", 8.5" x 11",
8.5" x 11"R, 8.5" x 5.5"
A3, B4, A4, B5, B5R
A3, B4, A4, B5, B5R
Selection between 8.5" x 13", 8.5" x 14" and
B4 can be made by the user setting.
B4 can be made by the user setting.
Document weight 50 to 200g/m
2
(13.3 to 53.3 lbs.)
(Duplex: 50 to 156g/m
2
(13.3 to 41.4 lbs.))
Stream feeding
mode
mode
Yes (Standby 5 sec)
Mixed-load
documents
documents
Yes
Length of time
taken for
document change
taken for
document change
0.68sec. or less
Document tray
guide display
guide display
A3R/A4, 11, B4R/B5, 8-1/2, A4R/A5, B5R
Communication
method
method
Serial communication
Reliability
MCBF: Min. 60K
MCBJ: Min. 10K
Life: 5 years or 500 K by original counter
MCBJ: Min. 10K
Life: 5 years or 500 K by original counter
Noise level
68dB or less
Power supply
From main unit (24V 2A)
Dimensions
(W x D x H)
(W x D x H)
607 x 508 x 121 mm (23.9 x 20 x 4.76 inch)
Space
requirement
(W x D)
requirement
(W x D)
822 x 508mm (32.4 x 20 inch) (With Exit tray)
Weight
Approx. 12 kg (Approx. 26.5lbs)
AR-C262M SPECIFICATIONS 3 - 11
3. Environment conditions
A. Operating environment conditions
(1) Temperature and humidity
(2) Power voltage and frequency
B. Storage environment conditions
C. Transit environment conditions
D. Standard temperature and humidity
Power voltage
Specified voltage ±10%
Power frequency
Specified frequency ±2%
30˚C (86˚F), 80%
35˚C (95˚F), 60%
Humidity
RH
Temperature
80%
20%
15˚C (59˚F)
35˚C (95˚F)
Humidity
RH
Humidity
RH
Machine
Consumable parts (Not unpacked)
Temperature
Temperature
90%
10%
90%
20%
40˚C (104˚F), 90%
40˚C (104˚F), 90%
50˚C (122˚F), 60%
–10˚C (14˚F)
50˚C (122˚F)
–5˚C (23˚F)
40˚C (104˚F)
Temperature
20 to 25°C (68 to 77°F)
Humidity
65 ±5%
Humidity
RH
Humidity
RH
Temperature
Temperature
Consumable parts
Machine
90%
10%
90%
20%
30˚C (86˚F), 90%
30˚C (86˚F), 90%
45˚C (113˚F), 60%
–20˚C (4˚F)
45˚C (113˚F)
–5˚C (23˚F)
40˚C (104˚F)
45˚C (113˚F), 60%