AR-203E/5420/M200/M201  SIMULATION, TROUBLE CODES  10 - 32
63
02
Black level automatic 
correction
[Function]
Used to acquire the black level target value used for the black level adjustment of white balance.
When this simulation is executed, the current correction value is displayed in 3 digits of 12bit
hexadecimal number.
Place the gray gradation chart (UKOG-0162FCZZ) used as the correction document so that the
density 10 (black side) comes on the left side and that the chart is upside down at the center of
the plate left center.
When [OK]/[ENTER]/[START] key is pressed, the mirror base unit scans the chart and calcu-
lates the correction value.
After completion of correction, the corrected value is displayed on the LCD/display.
* Default: 0
* If the value is set to the default, operation is made with 0x60.
[Operation] (AR-M200/M201)
12
Light quantity stabilization 
wait time setting
[Function]
Used to set the wait time before entering the light quantity level stable evaluation process in the
light quantity stable process of white balance. (Note: The light quantity stable level in the previ-
ous light quantity stable state is used as the target. When the light quantity level reaches the
target during the wait time, the set time of this simulation is ignored and the operation enters the
stable evaluation process.)
When this simulation is executed, the currently set value is displayed.
Enter the adjustment value with [ ] [ ] key
 
(or [Numeric] key for the AR-M200/M201) and
press [START] key. The entered value is stored and the machine goes into the sub code entry
standby mode.
Setting range: 0 – 99 (Complying with the light quantity stable wait time of 0 – 99sec.)
Default: 15 (15sec)
[Operation]
The operation is similar to simulation 09-04.
13
Light quantity stabilization 
band setting
[Function]
When the difference between the maximum and the minimum values of the light quantity level
sampled for 3.2sec in the cycle of 100msec in the white balance light quantity stable process is
within the range set with this simulation, it is judged as the light quantity is stable. (Note: The
magnification ratio of the AFE gain setting is automatically reflected on the stable width.)
When this simulation is executed, the currently set value is displayed.
Enter the adjustment value with [ ] [ ] key (or [Numeric] key for the AR-M200/M201) and
press [START] key. The entered value is stored and the machine goes into the sub code entry
standby mode.
Setting range: 1 – 99 (Light quantity stable width: Complying with 1 – 99 in 4095 gradations.)
Default: 16
[Operation]
The operation is similar to simulation 09-04.
Main 
code
Sub 
code
Contents
Details of function/operation
Chart back surface
 
10
1) Initial display
2) [OK]/[ENTER]/[START] key: 
Correction start
63-02 BLACK LEVEL
             000
63-02 BLACK LEVEL
EXECUTING...
<During canceling - When [Clear]/[Clear All] key is
pressed->
After canceling, the machine goes into the sub
code entry standby mode. 
3) After execution
3) In case of an error
THE JOB IS BEING
CANCELED.
63-02 BLACK LEVEL
             *** OK 
63-02 BLACK LEVEL
             *** ERR
AR-203E/5420/M200/M201  SIMULATION, TROUBLE CODES  10 - 33
64
01
Self print (1by2 mode)
[Function]
The status of the optical section is ignored and printing of one page is made. Also when the
print command is received from the host, printing is made.
When this simulation is executed, warm-up is performed and the ready lamp is lighted. (Since,
however, the scanner is disabled, initializing is not made.)
Enter the code number and press [OK]/[ENTER]/[START] key to start paper feed from the
selected cassette and print in the selected pattern.
* For 4 – 99, flip.
[Operation]
The operation is similar to simulation 26-02.
66
01
FAX soft SW setting 
(Executable only when the 
FAX is installed.)
[Function]
Use to check the FAX soft SW setting.
Every time when the key is pressed, the bit on the first line is switched 0 and 1.
[Operation]
02
FAX soft SW initializing 
(excluding the adjustment 
values) (Executable only 
when the FAX is installed.)
[Function]
Use to initializing FAX soft SW.
[Operation]
Main 
code
Sub 
code
Contents
Details of function/operation
Code number
Pattern 
Display item
0
1by2
1  BY  2
1
Grid pattern 
CHECK
2
White paper 
WHITE
3
Black background
BLACK
1) Initial display
∗ [Clear] key: FAX control is terminated.
2) Enter a 3-digit value of soft SW No. (To
enter the fourth digit, shift to the left.),
and the press [OK]/[ENTER] key.
"xxxxxxxx" is the set content.
∗ Select 2: Returns to the soft SW No. entry
display.
3) Select 1
4) Change with 1-8 of [Numeric] key and
the press [OK]/[ENTER] key.
"xxxxxxxx" is the set content.
∗ Select 2: Returns to the soft SW No. entry
display.
5) Select 1
After 2sec, returns to "1) Initial display".
ENTER FAX SOFT SW. #
(3 DIGITS)    SW.___
No.###    xxxxxxxx
CHANGE?   1:YES 2:NO
No.###    xxxxxxxx
USE # KEY   12345678
No.###    xxxxxxxx
STORED?   1:YES 2:NO
STORED
1) Initial display
After 2sec, FAX control is terminated.
INITIALIZED
AR-203E/5420/M200/M201  SIMULATION, TROUBLE CODES  10 - 34
66
03
FAX PWB memory check 
(Executable only when the 
FAX is installed.)
[Function]
Use to check the FAX PWB memory.
[Operation]
04
Signal send mode (Max. 
value) (Executable only 
when the FAX is installed.)
[Function]
Use to set the signal send mode (Max. value).
Facsimile simulation design specifications.
[Operation]
Main 
code
Sub 
code
Contents
Details of function/operation
1) Initial display
2) [
] [
] key or after 2sec
Every time when [
] key is pressed, the second line is changed in the sequence of No. 1
→ 2 → 3 → 1.
When [
] key is pressed, the sequence is reversed.
∗ [Clear] key: FAX control is terminated.
3) [OK]/[ENTER] key
4) After completion of check
• When the result is OK
• In case of sum check error
• In case of address bus
check error
• In case of data check error
• In case of data bus check
error
• In case of erase check error
∗ [Clear] key: Returns to "1) Initial display".
SELECT CHECK MEMORY
PRESS 
←, →
SELECT MEMORY (1-3)
1:DRAM
SELECT MEMORY (1-3)
2:SRAM
SELECT MEMORY (1-3)
3:FLASH
CHECKING MEMORY
MEMORY CHECK RESULT
                OK
MEMORY CHECK RESULT
XXXXXXXX SUM    NG
MEMORY CHECK RESULT
XXXXXXXX A-BUS  NG
MEMORY CHECK RESULT
XXXXXXXX DATA   NG
MEMORY CHECK RESULT
XXXXXXXX D-BUS  NG
MEMORY CHECK RESULT
XXXXXXXX ERASE  NG
1
NO SIGNAL
13
7200bps(V34)
25
2400bps(V27ter)
2
33600bps(V34)
14
4800bps(V34)
26
300bps(FLAG)
3
31200bps(V34)
15
2400bps(V34)
27
2100Hz(CED)
4
28800bps(V34)
16
14400bps(V33)
28
1100Hz(CNG)
5
26400bps(V34)
17
12000bps(V33)
29
300bps(V21)
6
24000bps(V34)
18
14400bps(V17)
30
2100Hz(ANSam)
7
21600bps(V34)
19
12000bps(V17)
31
DUMMY RING
8
19200bps(V34)
20
9600bps(V17)
32
NO VOICE ANSWER
9
16800bps(V34)
21
7200bps(V17)
33
NO RING BACK TONE
10
14400bps(V34)
22
9600bps(V29)
34
LINE OFF HOOK
11
12000bps(V34)
23
7200bps(V29)
35
LINE ON HOOK
12
9600bps(V34)
24
4800bps(V27ter)
1) Initial display
2) 2-digit (1-35) with [Numeric] key / [
] [
] key / 2sec after
Pressing [
] key or [
] key reverses the sequence.
∗ [Clear] key: FAX control is terminated.
3) [OK]/[ENTER] key: Send after setting
∗ [Clear] key: Returns to "1) Initial display".
SELECT OUTPUT SIGNAL
(2 DIGITS)    No.___
No. (1-35)
1:NO SIGNAL
.....
No. (1-35)
35:LINE ON HOOK
OUTPUTING SIGNAL MAX
PRESS CLEAR TO STOP
AR-203E/5420/M200/M201  SIMULATION, TROUBLE CODES  10 - 35
66
05
Signal send mode (Soft SW 
set value) (Executable only 
when the FAX is installed.)
[Function]
Use to set the signal send mode (Soft SW set value).
Facsimile simulation design specifications.
[Operation]
07
Image memory content print 
(Executable only when the 
FAX is installed.)
[Function]
Use to print the image memory content.
[Operation]
10
Image memory content clear 
(Executable only when the 
FAX is installed.)
[Function]
Use to clear the image memory content.
[Operation]
Main 
code
Sub 
code
Contents
Details of function/operation
1
NO SIGNAL
13
7200bps(V34)
25
2400bps(V27ter)
2
33600bps(V34)
14
4800bps(V34)
26
300bps(FLAG)
3
31200bps(V34)
15
2400bps(V34)
27
2100Hz(CED)
4
28800bps(V34)
16
14400bps(V33)
28
1100Hz(CNG)
5
26400bps(V34)
17
12000bps(V33)
29
300bps(V21)
6
24000bps(V34)
18
14400bps(V17)
30
2100Hz(ANSam)
7
21600bps(V34)
19
12000bps(V17)
31
DUMMY RING
8
19200bps(V34)
20
9600bps(V17)
32
NO VOICE ANSWER
9
16800bps(V34)
21
7200bps(V17)
33
NO RING BACK TONE
10
14400bps(V34)
22
9600bps(V29)
34
LINE OFF HOOK
11
12000bps(V34)
23
7200bps(V29)
35
LINE ON HOOK
12
9600bps(V34)
24
4800bps(V27ter)
1) Initial display
2) 2-digit (1-35) with [Numeric] key / [
] [
] key / 2sec after
Pressing [
] key or [
] key reverses the sequence.
∗ [Clear] key: FAX control is terminated.
3) [OK]/[ENTER] key: Send after setting
∗ [Clear] key: Returns to "1) Initial display".
SELECT OUTPUT SIGNAL
(2 DIGITS)    No.___
No. (1-35)
1:NO SIGNAL
.....
No. (1-35)
35:LINE ON HOOK
OUTPUTING SIGNAL SSW
PRESS CLEAR TO STOP
• When print is allowed
After completion of printing,
FAX control is terminated.
• When there is no print data
After 2 sec, FAX control is 
terminated.
• When print is inhibited
After 2 sec, FAX control is 
terminated.
PRINT STORED
NO DATA
CAN NOT PRINT
• When there are some print data
After completion of memory clear, the buzzer
sounds.
Remains unchanged until the power is turned
off.
• When there are no print data
After completion of memory clear
After 2sec, FAX control is terminated.
CLEAR IMAGE MEMORY
CLEARED
PLEASE POWER OFF
CLEAR IMAGE MEMORY
CLEARED
Page of 127
Display

Click on the first or last page to see other AR-203 (serv.man5) service manuals if exist.