DOWNLOAD Sharp AR-203 (serv.man5) Service Manual ↓ Size: 14.96 MB | Pages: 127 in PDF or view online for FREE

Model
AR-203 (serv.man5)
Pages
127
Size
14.96 MB
Type
PDF
Document
Service Manual
Brand
Device
Copying Equipment / AR203 Service Manual
File
ar-203-sm5.pdf
Date

Sharp AR-203 (serv.man5) Service Manual ▷ View online

AR-203E/5420/M200/M201  SIMULATION, TROUBLE CODES  10 - 36
66
11
300bps signal send (Max. 
value) (Executable only 
when the FAX is installed.)
[Function]
Use to set the 300bps signal send (Max. value).
1: NO SIGNAL
2: 11111
3: 11110
4: 00000
5: 010101
6: 00001
[Operation]
12
300bps signal send (Soft 
SW set value) (Executable 
only when the FAX is 
installed.)
[Function]
Use to set the 300bps signal send (Soft SW set value).
1: NO SIGNAL
2: 11111
3: 11110
4: 00000
5: 010101
6: 00001
[Operation]
Main 
code
Sub 
code
Contents
Details of function/operation
1) Initial display
2) [
] [
] key or after 2sec
Every time when [
] key is pressed, the second line is changed in the sequence of No. 1
→ 2 → 3 → 4 → 5 → 6 → 1.
When [
] key is pressed, the sequence is reversed.
∗ [Clear] key: FAX control is terminated.
3) [OK]/[ENTER] key
∗ [Clear] key: Returns to "1) Initial display".
SELECT SIGNAL
PRESS 
←, →
SELECT SIGNAL (1-6)
1:NO SIGNAL
.....
SELECT SIGNAL (1-6)
6:00001
OUTPUTING SIGNAL MAX
PRESS CLEAR TO STOP
1) Initial display
2) [
] [
] key or after 2sec
Every time when [
] key is pressed, the second line is changed in the sequence of No. 1
→ 2 → 3 → 4 → 5 → 6 → 1.
When [
] key is pressed, the sequence is reversed.
∗ [Clear] key: FAX control is terminated.
3) [OK]/[ENTER] key
∗ [Clear] key: Returns to "1) Initial display".
SELECT SIGNAL
PRESS 
←, →
SELECT SIGNAL (1-6)
1:NO SIGNAL
.....
SELECT SIGNAL (1-6)
6:00001
OUTPUTING SIGNAL SSW
PRESS CLEAR TO STOP
AR-203E/5420/M200/M201  SIMULATION, TROUBLE CODES  10 - 37
66
13
Dial test (Executable only 
when the FAX is installed.)
[Function]
Use to the dial test.
[Operation]
17
DTMF signal send (Max. 
value) (Executable only 
when the FAX is installed.)
[Function]
Use to set the DTMF signal send (Max. value).
[Operation]
Main 
code
Sub 
code
Contents
Details of function/operation
■ Dial test (PULSE)
1) Initial display
∗ [Clear] key: FAX control is 
terminated.
2) Select 1
3) Enter the make time in 2 digits.
XXXX: Default
∗ After deleting with [Clear] key, input
can be made.
4) [OK]/[ENTER] key
"yy" is the selected pulse 10 or 20.
"xx" is the input value.
∗ Select 2: Returns to “2)” display.
5) Select 1
Switched to 10/20PPS set with
pulse selection inside.
6) After setting
7) After completion of sending
∗ Select 2: Returns to “4)” display.
8) Select 1
After 2sec, returns to "1) Initial display".
SELECT SIGNAL
1:PULSE    2:DTMF
INPUT MAKE TIME
(0-15)            __
INPUT DIAL #
XXXX
SEND yyPPS xxms
1:YES 2:NO
SENDING yyPPS xxms
TERMINATE ?
1:YES 2:NO
TERMINATED
■ Dial test (DTMF)
1) Initial display
∗ [Clear] key: FAX control is terminated.
2)
Select 2
↓ Select 2
3)
Select 1
↓ Select 2
4) Select 1
XXXX: Default
∗ After deleting with [Clear] key, input can be
made.
4) [OK]/[ENTER] key
"xx" indicates HI, and "yy" indicates Low Soft SW.
∗ Select 2: Returns to “4)” display.
5) Select 1
HI/LO is selected with the signal level inside.
6) After setting the signal send level
7) After completion of sending
∗ Select 2: Returns to “4)” display.
8) Select 1
After 2sec, returns to "1) Initial display".
SELECT SIGNAL
1:PULSE    2:DTMF
SELECT HIGH LEVEL
1:DEFAULT 2:SOFT SW.
INPUT VALUE
(0-15)            __
SELECT LOW LEVEL
1:DEFAULT 2:SOFT SW.
INPUT VALUE
(0-15)            __
INPUT DIAL #
XXXX
H:xx        L:yy
1:YES 2:NO
SENDING DTMF
TERMINATE ?
1:YES 2:NO
TERMINATED
1) Initial display
∗ [Clear] key: FAX control is terminated.
2) [Numeric] key input
The content selected with signal send
level selection is set inside.
3) Communication is started after setting the
signal send level.
∗ [Clear] key: Returns to "1) Initial display".
INPUT DIAL #
SENDING SIGNAL MAX
PRESS CLEAR TO STOP
AR-203E/5420/M200/M201  SIMULATION, TROUBLE CODES  10 - 38
66
18
DTMF signal send (Soft SW 
set value) (Executable only 
when the FAX is installed.)
[Function]
Use to set the DTMF signal send (Soft SW set value).
[Operation]
21
FAX information print 
(Executable only when the 
FAX is installed.)
[Function]
Use to print the FAX information.
[Operation]
24
FAST SRAM clear 
(Executable only when the 
FAX is installed.)
[Function]
Use to clear the FAST SRAM.
[Operation]
30
TEL/LIU status change 
check (Executable only 
when the FAX is installed.)
[Function]
Use to check the TEL/LIU status change.
[Operation]
Main 
code
Sub 
code
Contents
Details of function/operation
1) Initial display
∗ [Clear] key: FAX control is terminated.
2) [Numeric] key input
The content selected with signal send
level selection is set inside.
3) Communication is started after setting the
signal send level.
∗ [Clear] key: Returns to "1) Initial display".
INPUT DIAL #
SENDING SIGNAL SSW
PRESS CLEAR TO STOP
1) Initial display
2) [
] [
] key or after 2sec
Every time when [
] key is pressed, the second line is changed in the sequence of 1 
→ 2
→ 3 → 1.
When [
] key is pressed, the sequence is reversed.
∗ [Clear] key: FAX control is terminated.
3) [OK]/[ENTER] key
• When print is allowed
After completion of printing,
FAX control is terminated.
• When print is inhibited
After 2sec, FAX control is 
terminated.
SELECT REPORT (1-3)
PRESS 
←, →
SELECT REPORT (1-3)
1:USER SW. LIST
SELECT REPORT (1-3)
2:SOFT SW. LIST
SELECT REPORT (1-3)
3:PROTOCOL
PRINT STORED
CAN NOT PRINT
1) Initial display
2) After completion of clearing
After 2sec, FAX control is terminated.
CLEAR FAST SRAM
CLEARED
1) Initial display
The display is switched every 2sec.
∗ [Clear] key: FAX control is terminated.
HS2 :xxx  HS1 :xxx
RHS :xxx  EXHS:xxx
CHECKING
PRESS CLEAR TO STOP
AR-203E/5420/M200/M201  SIMULATION, TROUBLE CODES  10 - 39
66
33
Signal detection check 
(Executable only when the 
FAX is installed.)
[Function]
Use to check the signal detection.
[Operation]
34
Communication time 
measurement (Executable 
only when the FAX is 
installed.)
[Function]
Use to measurement the communication time.
[Operation]
37
Speaker sound volume 
setting (Executable only 
when the FAX is installed.)
[Function]
Use to set the speaker sound volume.
1: NO SOUND
2: LOW
3: MID
4: HIGH
[Operation]
Main 
code
Sub 
code
Contents
Details of function/operation
1) Initial display
When a signal is detected, the display is changed from NONE to the following.
CI/CNG/CED/BT/DT/Flag/SDT/DTMF
∗ [Clear] key: FAX control is terminated.
CHECKING        NONE
PRESS CLEAR TO STOP
1) Initial display
"xx:xx:xx:xxx" indicates o'clock, minute, second, millisecond.
∗ [Clear] key: FAX control is terminated.
COMM. TIME
xx:xx:xx:xxx msec
1) Initial display
2) [
] [
] key or after 2sec
Every time when [
] key is pressed, the second line is changed in the sequence of 1 
→ 2
→ 3 → 4 → 1.
When [
] key is pressed, the sequence is reversed.
∗ [Clear] key: FAX control is terminated.
3) [OK]/[ENTER] key
xxx: Set content
After 2sec, FAX control is terminated.
SELECT SPEEKER VOL.
PRESS 
←, →
SELECT (1-4)
1:NO SOUND
SELECT (1-4)
2:LOW
.....
STORED
xxx
Page of 127