DOWNLOAD Sharp PN-L603A (serv.man3) Service Manual ↓ Size: 52.15 MB | Pages: 127 in PDF or view online for FREE

Model
PN-L603A (serv.man3)
Pages
127
Size
52.15 MB
Type
PDF
Document
Service Manual
Brand
Device
Monitor
File
pn-l603a-sm3.pdf
Date

Sharp PN-L603A (serv.man3) Service Manual ▷ View online

PN-L703A/L703B, PN-70TA3/70TB3, PN-L603A/L603B, PN-60TA3/60TB3 
  SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4- 31 
3 ) Then, following window appears. 
The bar progresses, if it communicates well.     
 
 
 
 
 
If following window appears, it failed to communicate. 
Then, check the connection cable and setting. 
 
 
 
 
4 ) If the progress bar reaches right edge, the appearance 
changes as below. 
 
 
 
 
 
 
 
 
 
 
Display information appears on ITEM column on upper side of 
the window. 
Log data are separated into System Log and Temp Log. 
Sysytem Log mainly displays user operation and machine 
condition. 
Temp Log displays temperature information. 
 
(MEMO) 
- This tool is not available for models which are not displayed on 
the list of Model Name. Ver2.1.2.0 and subsequent version of 
“InfoDisp Report” tool does not work properly with the models 
older than PN-R series. In addition, the report file format is not 
compatible. 
The Ver2.1.2.0 and subsequent version of “InfoDisp Report” tool 
does not support data storage in CSV format. In case the data 
are read in Excel etc., store the data in HTML format. 
16-4. SYSTEM LOGS AND TAB
 
Logs are displayed with list format downside. Each item’s 
meanings are below. 
LOG’S MEANING 
LOG KIND 
 
 
Header
 
Meaning and remark
 
ID 
The smaller the number, the newer the log 
data. 
Use [ID] to line up in the order of operation. 
Date 
It displays date and time when operation 
occurred. The icon is displayed on left edge 
to stand out, if “Kind” is “Abnormal State”. 
Time elapsed from 
Power Supply 
It displays the operation time. (The time after 
turning on the power of the monitor.)       
Kind 
It displays the kind of log. Detail information 
is described in “Log Kind”. 
Input 
If “Kind” is “Operation” or “Abnormal State”, it 
displays the input source of main screen. If 
“Kind” is “Change Signal”, it displays the 
input source which signal is changed and 
displays which screen (Main or Sub)’s signal 
is changed in parenthesis. If “Kind” is “Power 
Off Reason”, it displays none. 
Information 
It displays information depending on “Kind”. 
Detail information is described in “Log Kind”.
Parameter 1/2 
It displays parameter. Detail information is 
not open. 
Header
 
Meaning and remark
 
Abnormal State 
Log 
 
It displays the log about abnormal 
state, for example “Temperature error”.   
Abnormal kind is displayed in 
“Information”. 
Change Power 
State Log 
 
It displays the log of power off. The 
reason of power change is displayed in 
“Information”. 
Change Signal 
Log 
It displays the log changing signal.   
The timing of new signal is displayed in 
“Information” as “[Width] x [Height] @ 
[Refresh rate]” or “No Signal”. 
PN-L703A/L703B, PN-70TA3/70TB3, PN-L603A/L603B, PN-60TA3/60TB3 
  SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4- 32 
 
 
16-5. TEMP LOG AND TAB
 
The temperature information is displayed in the Temp log.     
 
 
 
16-6. SAVE AND OPEN LOGS 
 
It is possible to save in either original format (.IDR format) or 
HTML format (.HTML format).     
* To analyze the logs, save the log as the original format (.IDR 
format).      It is possible to read and display the files saved in 
the USB flash drive.     
Save logs 
   
1) Click [Create Report] to save logs in file. 
 
 
 
 
2) Following window appears, then specify the file name and click 
[Save] button. 
 
 
 
 
 
 
 
 
 
 
Header
 
Meaning and remark
 
 Operation 
with 
IR 
Remote/Key 
It displays the log of operations 
with IR remote or button on body. 
Operation record is displayed in 
“Information”. 
 Operation 
by 
 
RS-232C
Operation) 
It displays the log of operation by 
RS-232C command. The 
command is displayed in 
“Information”. 
 Extended 
Operation 
by RS-232C 
(Operation) 
The sent command is displayed in 
“Information”. 
 Operation 
by 
Browser(Operation) 
It displays the log of operation by 
browser. The command the 
occurred by operation 
(RS-223C/LAN command) is 
displayed in “Information” 
 Extended 
Operation 
by Browser 
Operation) 
 Other 
Operation 
Operation) 
It displays the log of operation 
except above, for example, power 
off by schedule timer. Operation 
kind is displayed in “Information”.
 
 
Developer Info 
It displays the Information for the 
developer.   
Header 
Meaning and remark 
current temperature 
Temperature  when  receiving 
the log.   
direction Installed 
Orientation 
 
0:Landscape/1:Portrait 
bright control thresh high 
temperature error thresh 
power off thresh 
Temperature of the abnormal 
operation of the monitor   
minimum temperature 
Minimum temperature of   
monitor 
The minimum temperature is   
displayed when the power of 
the monitor is turned on.     
maximum temperature 
Maximum temperature   
The maximum temperature is 
displayed when the power of 
the monitor is turned on. 
bright down count 
The  number  of  brightness 
decrease caused by high 
temperature is displayed.     
high temperature count 
The number of high 
temperature error is displayed.   
power off count 
The number of being turned off 
caused by  high temperature 
is displayed   
Log 
The latest five logs of Bright 
down/ high temperature/ power 
off are displayed.     
PN-L703A/L703B, PN-70TA3/70TB3, PN-L603A/L603B, PN-60TA3/60TB3 
  SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4- 33 
3) The stored log file can be read with selecting “File” - “Open 
Report File” in menu bar. 
Save logs in HTML format
     
1) When “File” - “Open Report File” in menu bar is selected, the 
dialog for saving is displayed.     
2) Specify the file name and push [Save] button. 
Display log saved in USB flash drive 
   
It is possible to display the log saved in the USB flash drive.     
To save the log, refer to the “14-6 SAVE AND OPEN LOGS.”.     
1) When “File” - “Open Report File” in menu bar is selected, the 
dialog for saving is displayed.     
When “xxlog_[Model name]_[Serial number]_[Date].dat” file is 
opened, the log is displayed.     
Display of a system log attached to an abnormality 
notification mail
 
If a log file of the display is attached to an abnormality 
notification mail, it can be read by the use of this tool. 
1) Save the file attached to an abnormality notification mail.     
2) Select “File” - “Open Log File (Binary)” of the menu bar, and 
select the saved file     
3) The display log when detecting an abnormality is displayed.   
 
16-7. DUMP NVRAM
 
This tool is provided with the dump acquiring function of the 
NVRAM of the information display in order to check the status 
when a trouble occurs as well as to acquire and display the logs.     
1) Click [Get All Reports] button.     
 
 
 
2) Following window appears. Then, specify the folder you want to 
store dump files and push [OK] button. 
 
 
 
 
 
 
 
 
 
 
 
3) Following window appears. The bar progresses if it 
communicates well. 
   
 
 
 
4) Following window appears after communication complete. Click 
[OK] button. 
 
 
 
 
5) If following window appears, it failed to communicate. Then, 
check the connection cable and the setting.     
 
 
 
 
 
16-8. OTHER FUNCTIONS
 
Sort logs
 
The logs are listed at first. You can sort in order of another to push 
header. For example, if you push [Kind] header, the list is sorted in 
order of “Kind” as below.   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
PN-L703A/L703B, PN-70TA3/70TB3, PN-L603A/L603B, PN-60TA3/60TB3 
  SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4- 34 
Compensate log time
 
This tool can compensate log time with PC’s time, because 
information display is not set date and time.     
<CAUTION> 
It cannot display correct time in case that PC’s time is not correct 
when it get logs or in case that user changed information 
display’s date or time within the range of logs.     
Select “View” - “Compensate Log Time by PC Time” in menu bar. 
Then, the item in menu is checked and “Date” is compensated 
by PC’s time. (It’s not checked and not compensated as default.)     
 
Clear logs
 
Select “File” - “Clear Logs” in menu bar. Then, confirming dialog 
as below appears. 
Logs stored in information display will be removed if you push 
[OK] button.     
 
 
 
 
 
It erases logs in information display and list, so logs should be 
stored to file if you need to find out a problem. 
For the logs of “Power OFF cause,” “Signal change,” and 
“Operation,” when the number of items exceeds the maximum 
number, the oldest one is deleted and the newest one is saved. 
When, however, even one log of “Abnormal state” is saved, the 
logs of “Power OFF cause,” “Signal change,” and “Operation” are 
not revised in order to maintain the analysis information at 
occurrence of the abnormality. In such a case, clear the logs with 
this function. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Page of 127
Display

Click on the first or last page to see other PN-L603A (serv.man3) service manuals if exist.