DOWNLOAD Sharp PN-L603A (serv.man3) Service Manual ↓ Size: 52.15 MB | Pages: 127 in PDF or view online for FREE

Model
PN-L603A (serv.man3)
Pages
127
Size
52.15 MB
Type
PDF
Document
Service Manual
Brand
Device
Monitor
File
pn-l603a-sm3.pdf
Date

Sharp PN-L603A (serv.man3) Service Manual ▷ View online

PN-L703A/L703B, PN-70TA3/70TB3, PN-L603A/L603B, PN-60TA3/60TB3 
  SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4- 23 
10-2. WHEN REPLACING THE PANEL OR WHEN 
THE OLD PWB DOES NOT WORK 
Reset the setting to the initial state according to the following 
procedures. 
1 ) Display any image on the screen. 
2 ) Display SERVICE MENU2. 
3 ) Select [GAMMA SETTING] with [VOL + ()], [VOL - ()] 
buttons, and press [ENTER] button. 
The GAMMA SETTING menu is displayed. 
4 ) Select [LEVEL] with [VOL + ()], [VOL - ()] buttons, and press 
[ENTER] button. 
The LEVEL menu is displayed. 
5 ) Select [RESET] with[VOL + ()], [VOL - ()], [BRIGHT - 
( )],[BRIGHT + ()] buttons, and press [ENTER] button. 
6 ) Check to confirm that the set values are changed as shown 
below.
 
INITIAL VALUES 
 
 
 
 
 
 
 
 
 
7 ) Select [OK] with [BRIGHT - ( )],[BRIGHT + ()] buttons, and 
press [ENTER] button. 
The display returns to the GAMMA SETTING menu. 
8 ) Select [RESET] with[VOL + ()], [VOL - ()], [BRIGHT - 
( )],[BRIGHT + ()] buttons, and press [ENTER] button. 
9 ) Check to confirm that all the set values are changed as shown 
below.
 
 
 
 
 
 
 
 
 
 
10) Select [OK] with [BRIGHT + ()] buttons, and press [ENTER] 
button. GAMMA SETTING menu is closed. 
11) Read the GAMMA setting values to check that all values are 
properly set. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
PN-L703A/L703B, PN-70TA3/70TB3, PN-L603A/L603B, PN-60TA3/60TB3 
  SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4- 24 
11. GAMMA SETTING TOOL OPERATION PROCEDURES                                 
 
 
11-1. OPERATING CONDITIONS OF THE GAMMA 
SETTING TOOL 
The operating conditions of the Gamma setting read tool of the 
information display are as follows. 
OS 
(32bit Only) 
 -  Windows 8 
 -  Windows Vista 
 -  Windows 7 
An authorized copying and distribution 
package of Microsoft Visual C++ 2005 or 
later is required to be installed. 
Communication 
port 
 -  LAN(100 BASE-TX / 10BASE-TX) 
 
■  When connected to the information display 
with a LAN cable 
 
Refer to the followings of [7. INSTRUCTIONS FOR LAUNCHER 
TOOL] to connect the information display and the PC.     
 
■  Connected to the information display with a LAN cable 
■  How to prepare the network settings 
■  How to set PC automatically with using DHCP 
■  How to set PC manually without using DHCP 
■  How to set Information Display with using DHCP 
■  How to set Information Display without using DHCP 
■  How to confirm the connection of PC and Information display 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
11-2. SETTING PROCEDURES WITH THE GAMMA 
SETTING TOOL 
■  When replacing the PWB (When the panel is 
not changed) 
<BOOTING PROCEDURES OF THE GAMMA SETTING 
TOOL> 
Press [Gamma] button of the service tool launcher.. 
 
 
 
 
 
 
 
 
 
 
<READING PROCEDURES OF THE SETTING> 
The reading procedures of the Gamma setting before 
replacement by using the Gamma setting tool are as follows: 
1) Press [Connection Setting] button and perform the 
communication setting. 
2) Turn ON the power of the information display. 
3) Press [Read&Save] button. 
4) When reading of all the setting contents is completed, the set 
value is displayed and the dialog of saving the file is displayed.   
The initial file name at that time is “[Model name]_[Serial 
number]_[Date(YYYYMMDD)].” Check the file name and press 
[Save] button to save the setting value. 
5) Check to confirm that “K” mark is not displayed on the left upper 
corner of the display. If “K” mark is displayed, perform the       
reading procedure again. 
6) Check to confirm that the Level value of the read setting 
information is same as that shown in the above figure. 
If the Level value of the read setting information differs from 
that in the above figure, the setting data cannot be taken over. 
In such a case, refer to [n WHEN REPLACING THE PANEL 
OR WHEN THE OLD PWB DOES NOT OPERATE] and reset 
the setting information to the default value. (Normally this does 
not happen unless the value is individually changed.) 
PN-L703A/L703B, PN-70TA3/70TB3, PN-L603A/L603B, PN-60TA3/60TB3 
  SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4- 25 
<WRITING THE GAMMA SETTING VALUE> 
The writing procedures of the read setting value with the Gamma 
setting tool after replacement of the PWB is as follow: 
1) Press [Connection Setting] button and perform the 
communication setting. 
2) Turn ON the power of the information display. 
3) Press [LoadFile...] button and select the setting file which was 
saved. 
4) Press [Write] button to write the setting value. 
5) Check to confirm that “K” mark is not displayed on the left upper 
corner of the display. If “K” mark is displayed, perform the     
reading procedure again. 
<CAUTION> 
If the message of “This Monitor is not Support. Is write processing 
continued?”, “Writing data is not for this monitor. Is write 
processing continued?”, 
“Serial Number is different between monitor and writing data. 
Is write processing continued?”, or “Model Name is different 
between monitor and writing data. Is write processing continued?” 
is displayed, the value to be written may be different from the 
value of the read setting data. Check again and perform writing 
again. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
■  When replacing the panel or when the old 
PWB does not operate 
Reset the setting to the default state as follows: 
1) Press [Connection Setting] button and perform the 
communication setting. 
2) Turn ON the power of the information display. 
3) Press [Reset] button, and the Gamma setting is reset to the 
default value. 
4) Check to confirm that “K” mark is not displayed on the left upper 
corner of the display. If “K” mark is displayed, perform the 
reading procedure again. 
<CAUTION> 
If the message of 
“This Monitor is not Support. Is write processing continued?”, 
“Writing data is not for this monitor. Is write processing 
continued?”, or “Model Name is different between monitor and 
writing data. Is write processing continued?” 
is displayed, the value to be initialized may be different from the 
value of this model. Check again and perform initialization again. 
 
(MEMO) 
WHEN “TIME OUT. CANNOT CONNECT. PLEASE 
CONFIRM SETTING.” IS DISPLAYED: 
Check the power state of the information display.   
If “Read&Save” is executed under the power standby state, the 
operation may fail on rare occasions. With the power ON, press 
[Read&Save] button again to read the setting. 
Check to confirm that the PC and the information display are 
connected with an RS-232C cable properly. 
WHEN “CANNOT OPEN INTERFACE. CANNOT 
CONNECT. PLEASE CONFIRM SETTING” IS 
DISPLAYED: 
Check to confirm that the COM port is not set by another tool. 
If the COM port is set by another tool, terminate that tool and 
press [Read&Save] button again to read the setting value. 
WHEN “THIS MONITOR IS NOT SUPPORT. IS XXXX 
PROCESSING CONTINUED?” IS DISPALYED: 
The tool connected to the display does not support the display. 
Use a tool which supports the display.
 
 
 
 
 
 
 
 
 
 
 
PN-L703A/L703B, PN-70TA3/70TB3, PN-L603A/L603B, PN-60TA3/60TB3 
  SERVICE MENU/VARIOUS SETTING TOOL OPERATING PROCEDURES 4- 26 
12. SERIAL NUMBER WRITING PROCEDURES                                                 
 
 
12-1. OPERATING CONDITIONS OF THE SERIAL 
NUMBER SETTING TOOL 
The operating conditions of the Gamma setting read tool of the 
information display are as follows. 
OS 
(32bit Only) 
 -  Windows 8 
 -  Windows Vista 
 -  Windows 7 
Communication 
port 
 -  LAN(100 BASE-TX / 10BASE-TX) 
 
■  When connected to the information display 
with a LAN cable 
 
Refer to the followings of [7. INSTRUCTIONS FOR LAUNCHER 
TOOL] to connect the information display and the PC.     
 
■  Connected to the information display with a LAN cable 
■  How to prepare the network settings 
■  How to set PC automatically with using DHCP 
■  How to set PC manually without using DHCP 
■  How to set Information Display with using DHCP 
■  How to set Information Display without using DHCP 
■  How to confirm the connection of PC and Information display 
 
12-2. START-UP OF THE SERIAL NUMBER 
SETTING TOOL 
Press [Serial Number] button of the Service Tool Launcher.
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
12-3. SERIAL NUMBER SETTING PROCEDURES 
 
 
 
 
 
 
 
 
 
 
The procedures of setting serial numbers with use of the Serial 
Number Setting Tool are as follows. 
1) Press [Connection Setting...] button to configure the 
communication settings. 
2) Input the serial number you need to set in the field of Write 
Data. 
3) Press [Write] button. 
4) Press [Read] button, and confirm that the set serial number is 
displayed in the Read Data field.. 
 
12-4. SERIAL NUMBER CHECK METHOD 
Press [Display] button on the remote controller to indicate the 
display information, and check the serial number.
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Page of 127
Display

Click on the first or last page to see other PN-L603A (serv.man3) service manuals if exist.