Sharp UP-3301 (serv.man9) Service Manual ▷ View online
UP-3301VS
SERVICE PRECAUTION
– 11 –
3. POS UTILITY TOOLS
1) OUTLINE
This Specification document describes the explanation about
"POSUTILITYTOOL.EXE and "02FD.EXE".
"POSUTILITYTOOL.EXE and "02FD.EXE".
"POSUTILITYTOOL.EXE"and "02FD.EXE" works on Windows 95/98 of
PC and they have the following
Functions by connecting UP-3301 with RS232.
2) CONNECTION
PC and UP-3301 are connected by RS232.
Connect the CH2 port of the UP-3301 to the RS-232 interface of the
PC.
RS232 Cable Connecting:
3) PROCEDURE
3) -1. POS UTILITY
POSUTILITYTOOL.EXE: IPL of UP-3301 Program Object
02FD.EXE:
All RAM Data Upload/Download
(PC software tool instead of the current
ER-02FD.)
ER-02FD.)
PC
D-SUB 9pin - D-SUB 9pin
cable
cable
D-sub 9pin
/CD
RD
SD
/ER
GND
/DR
/RS
/CS
/CI
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
RD
SD
GND
[PC]
UP-3301
D-sub 9pin
No
Procedure on P.C. side
No
Procedure on UP-3301 side
1
Install the "POSUTILITYTOOL.EXE" on the P.C.
2
Turn OFF the power.
3
Select "IPL Mode".
Set the "IPL Switch" of the UP-3301 to "ON".
Set the "IPL Switch" of the UP-3301 to "ON".
4
Turn ON the power.
5
Starting of "IPL Mode".
The UP-3301 displays
"IPL from Serial I/O"
The UP-3301 displays
"IPL from Serial I/O"
6
Connect the P.C. and the UP-3301 (CH2) via RS232. (Fig 1)
IPL SW
ON
UP-3301VS
SERVICE PRECAUTION
– 12 –
7
Execute the "POSUTILITUTOOL.EXE" on the P.C.
*Please close all other applications while using this utility.
*Please close all other applications while using this utility.
8
Select the ROM object Files by clicking the "Add Files.." button.
9
Push the "SEND" button.
Program data is sent to the UP-3301 automatically.
Program data is sent to the UP-3301 automatically.
9
Program data is received from the P.C. automatically.
The UP-3301 displays.
The UP-3301 displays.
10
When data sending is completed,
the initial Window is shown after "Complete" window.
the initial Window is shown after "Complete" window.
10
The UP-3301 displays
"Completed."
"Completed."
11
Turn OFF the power.
12
Select "Normal Mode".
Set the "IPL switch" to "OFF".
Set the "IPL switch" to "OFF".
13
Execute the "Service Reset" on UP-3301.
No
Procedure on P.C. side
No
Procedure on UP-3301 side
UP-3301VS
SERVICE PRECAUTION
– 13 –
3) -2. 02FD
No
Procedure on P.C. side
No
Procedure on UP-3301 side
1
Install the "02FD.EXE" on the P.C.
ALL RAM Data UpLoad : Go to "2"
ALL RAM Data DownLoad : Go to "9"
ALL RAM Data DownLoad : Go to "9"
2
ALL RAM Data UpLoad
Connect the P.C. and the UP-3301 (CH2) via RS232.
Connect the P.C. and the UP-3301 (CH2) via RS232.
2
Enter the SRV mode.
Select " 2 SETTING ".
Select " 2 SETTING ".
Select " 13 DATA SEND"
3
The UP-3301 displays
4
Execute the "02FD.EXE" on the P.C.
*Please close all other applications while using this utility.
5
Set the Communication method by pushing the "Setting" Button.
Push the "OK" Button.
6
Push the "[POS
3
PC]" Button.
And Select the Receiving File.
7
Communication starts.
7
Push CASH key. The UP-3301 displays
8
The UpLoad is completed.
The initial Window is shown.
Push the "Exit" Button.
8
The UpLoad is completed.
The SETTING menu is shown.
9
ALL RAM Data UpLoad
Connect the P.C. and the UP-3301 (CH2) via RS232.
9
Enter the SRV mode.
Select " 2 SETTING".
Select " 14 DATA RECEIVE"
Select " 14 DATA RECEIVE"
10
The UP-3301 displays
Push the CASH key.
UP-3301VS
SERVICE PRECAUTION
– 14 –
4. UTL33.EXE (UP-3301 Series Utility tool)
1. Outline
This specification covers the utility program “UTL33.EXE” for UP-3301
series. The “UTL33.EXE” is a program which runs on the PC DOS
series. The “UTL33.EXE” is a program which runs on the PC DOS
prompt screen, it is connected to the UP-3301 by RS232 (CH2). It has
the following functions: (1) UP-3301 IPL operation; (2) LOGO data
rewrite for built-in printer UP- T80BP; and (3) program rewrite.
rewrite for built-in printer UP- T80BP; and (3) program rewrite.
2. System requirements
PC and UP-3301 are connected by RS232 (CH2).
3. Functions
The following three functions become available:
(1) UP-3301 program rewrite (IPL)
The UP-3301 program is updated. S-type files or ER01FD type data
files are used for ROM data.
(2) LOGO data rewrite
The LOGO STAMP data for the UP-T80BP is set.
Black-and-white BMP/PCX data is used and the image size is up to
Black-and-white BMP/PCX data is used and the image size is up to
576 x 240 dots.
(3) Program rewrite (IPL)
The UP-T80BP program is updated. S-type files are used for ROM
data.
data.
According to the contents of the file, “UTL33.EXE” automatically
selects the appropriate protocol from the three types described
above. 1
above. 1
11
Execute the "02FD.EXE" on the P.C.
*Please close all other applications while using this utility.
12
Set the Communication method by pushing the "Setting" Button.
Push The "OK" Button.
13
Push the "[POS
3
PC]" Button.
And Select the Sending File.
14
Communication starts.
14
The UP-3301 displays
15
The DownLoad is completed.
The initial Window is shown.
The initial Window is shown.
Push the "Exit" Button.
15
The DownLoad is completed.
The SETTING menu is shown.
The SETTING menu is shown.
16
Execute the " Service Reset " on the UP-3301
No
Procedure on P.C. side
No
Procedure on UP-3301 side