Sharp 66GS-62 (serv.man19) Service Manual / Technical Bulletin ▷ View online

CTV 2004 03 03
Month of Issue:   22
nd
 July 2004
        
Classification: 
White
TELEVISION TECHNICAL BULLETIN
Page 1 of 4
Sharp Electronics (UK) Limited
Reference AvW 10 03 2004 - 3
Revision - 3
White – Carry out as required
Yellow – Carry out as required and whenever the unit comes in for service
 Red – Carry out on all units
MODEL
66GS62H
East/west faults
Faults in the east/west stage of this set can be complicated to find due to the type of circuit being used.  A problem in
this stage can also lead to a dead set.  It is recommended that when fault finding in this area, to follow the guidelines
given below.  Note that as this part of the circuit operates during the flyback period, it is very difficult to ‘scope’ any
waveforms.
The  east/west  control  transistor  (Q602)  has  to  be  turned  on  to  provide  voltage  to  the  collector  of  the  line  output
transistor  (Q601),  without  this  voltage,  the  line  will  not  come  up.    During  the  flyback  period,  the  on  time  of  Q602  is
varied to give more or less scan and therefore east/west correction.  The timing of this is critical and is controlled by the
microprocessor.
When the set starts up, there is no east/west correction; therefore Q602 will not be turned on.  As Q602 needs to be
turned on, there is a small circuit that provides this function.  R638 (100k ) is connected to the +5V line which connects
to the gate of Q602 via R657, D607, D604, D617, R612 and R616, pulling it high and turning it on at start up.  When the
set is running, the east/west control signal keeps turning Q602 on when necessary.
If it is suspected that there is a fault with the drive to Q602, not allowing it to turn on at start up, short out the source to
drain of this device and turn on.  Note that the picture will be extra large when this is done.  The next step is to see if the
driver circuit is faulty.  Disconnect R657 (D616 end) and apply 2.5V from a DC power supply to this end.  When the set
is turned on, it should start up.  If the voltage is varied between about 1.5V and 4.5V, the width should vary.  If it does
not there could be a problem with the drive circuitry.  Another component  that  will  cause  this  fault  is  the  line  output
transistor.  If it has been replaced with a BUH515, the flyback pulse will not be high enough to provide any east/west
correction.  It is therefore very important to ensure that a BUH515D is used in Q601 position.  This device must be
ordered from Sharp Parts Centre as it has been known for transistors supplied from other sources not to work, or work
incorrectly.
If the driver stage appears to be alright, examine the waveform on pin 99 of IC1001, this should be a parabola at 50Hz;
this  will  change  as  the  east/west  controls  are  adjusted.  If  there  is  no  waveform,  or  it  does  not  adjust,  blank  the
EEPROM (IC1003) using the appropriate jig (see the Memory and Processor Technical Bulletin for the 66GS62H).  If
this does not restore the output from IC1001, suspect IC1001.  Note that the type of IC1001 depends on the size of the
EEPROM fitted - see The GA10 Parts Technical Bulletin for more details. If the waveform changes when adjusted, then
the output circuit is probably faulty.
When fault finding in the east/west drive circuit, it is often found that one of the SMD diodes is faulty, normally caused
by failure of Q602.  When replacing Q602 be careful not to accidentally wipe R610 off the board.  R610 is in the control
circuit and if it is missing, Q602 will never turn on.  It is possible for any of the three driver transistors to fail (Q603,
Q604 and Q608).  It is recommended that if any of these transistors are suspect that all three are replaced together.
Large picture
For a large picture or east/west problems (sometimes can occur after replacing a short circuit line output transistor) can
be caused by Q602 going short circuit or leaky.  Also ensure that C601. C602, C619 and C624 are not dry jointed or
faulty in any way
CTV 2004 03 03
Month of Issue:   22
nd
 July 2004
        
Classification: 
White
TELEVISION TECHNICAL BULLETIN
Page 2 of 4
Sharp Electronics (UK) Limited
Reference AvW 10 03 2004 - 3
Revision - 3
White – Carry out as required
Yellow – Carry out as required and whenever the unit comes in for service
 Red – Carry out on all units
Gate
Source
Drain
R610
CTV 2004 03 03
Month of Issue:   22
nd
 July 2004
        
Classification: 
White
TELEVISION TECHNICAL BULLETIN
Page 3 of 4
Sharp Electronics (UK) Limited
Reference AvW 10 03 2004 - 3
Revision - 3
White – Carry out as required
Yellow – Carry out as required and whenever the unit comes in for service
 Red – Carry out on all units
Changes to the circuit during production
A number of changes were made to the east/west output circuit during production as follows:
1.  A larger heatsink was used for Q601 and Q602 to help reduce the operating temperature of these devices.  The
original heatsink is 65mm in height; the new one is 110mm in height.  If the heatsink has already been changed
for the larger type, it is not necessary to change it again.  See the picture relating to the new Q602 for new
heatsink.
2.  Q602 was changed for a more powerful device.
3.  The inner pincushion correction transistor, Q610 was up rated from a SMD device to a wire ended type.  The
new transistor is now mounted on the component side of the PWB.  If a set comes into the workshop, and this
resistor has not been changed, it is advisable to do so, using the part number for Q610 given below:
Original Q610 Transistor
      New Q610 Transistor
REF NO
DESCRIPTION
PART NUMBER
PRICE CODE
-
Heatsink
PRDARA018WJFW
AC
C601
Capacitor, 10nF 1.6kV
RC-FZ0158BMZZ
AF
C602
Capacitor, 4.7nF 1.5kV
RC-FZ0148BMZZ
AD
C619
Capacitor, 100nF 250V
RC-FZ0198BMZZ
AG
C624
Capacitor, 220nF 400V
RC-FZ7224BMNJ
AE
R610
SMD Resistor, 68
VRS-TV1JD680J
AA
Q601
Transistor, BUH515D
RH-TX0226BMZZ
AK
Q602
Transistor, 2SK2843
RH-TX0236BMZZ
AE
Q603
SMD Transistor, 2SC2412
VS2SC2412KQ-1
AA
Q604
SMD Transistor, 2SC2412
VS2SC2412KQ-1
AA
Q608
SMD Transistor, 2SA1037
VS2SA1037KQ-1
AA
Q610
Transistor, IFR640A
RH-TX0246BMZZ
AG
Note that the list of components given above IS NOT a parts list to cure all geometry problems in this chassis.  It has
been compiled to show all the part numbers for items refered to in this document.  If the parts noted in the text are not
faulty, carry out fault finding procedures to locate the problematic part.
CTV 2004 03 03
Month of Issue:   22
nd
 July 2004
        
Classification: 
White
TELEVISION TECHNICAL BULLETIN
Page 4 of 4
Sharp Electronics (UK) Limited
Reference AvW 10 03 2004 - 3
Revision - 3
White – Carry out as required
Yellow – Carry out as required and whenever the unit comes in for service
 Red – Carry out on all units
Circuit Diagram of the GA10 East/West Stage
Display

Sharp 66GS-62 (serv.man19) Service Manual / Technical Bulletin ▷ Download

  • DOWNLOAD Sharp 66GS-62 (serv.man19) Service Manual ↓ Size: 447.05 KB | Pages: 4 in PDF or view online for FREE
  • Here you can View online or download the Service Manual / Technical Bulletin for the Sharp 66GS-62 (serv.man19) in PDF for free, which will help you to disassemble, recover, fix and repair Sharp 66GS-62 (serv.man19) CTR. Information contained in Sharp 66GS-62 (serv.man19) Service Manual / Technical Bulletin (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.