Sharp UP-3301 (serv.man9) Service Manual ▷ View online

UP-3301VS
DIAGNOSTICS SPECIFICATIONS
– 27 –
1) CHANNEL Check
1
Check content
The CHANNEL setting of the connected RS232 is displayed. The
display content and the setting of the DIP SW for CHANNEL setting
on the RS232 I/F PWB are compared. 
Since the RS232, printer port and port for noncontact setting
on the main PWB of the UP-3301 is fixed to CH1, CH2, CH7 and
CH8. The ER-A7RS2 must be set to CH3~CH6.
(Reference) ER-A7RS2 CHANNEL setting (In the table below, "1" =
SW OFF, "0" = SW ON.)
ER-A7RS2 CON3
ER-A7RS2 CON4
2
Terminating procedure
Press the Touch panel to terminate the check.
2) CH1 Check
1
Check content
When the channel is not setting, an error is displayed
(ERROR:CH1). When the channel is setting, the following check is
performed. 
• Control signal check
The read check of the above inputs and the interruption check of CS,
CI, and CD are performed. 
In the read check, ER and RS are changed over in the above
sequence and the logic states of DR, CI, CD, and CS are checked. 
If the logic differs from that in the table, an error display is made. 
"ON" in the table means Active LOW, and "OFF" means Active HIGH. 
In the interruption check, an interruption of CS, CI, or CD is allowed
one by one. (The MASK is canceled.)
If an interruption is not made when each signal is active, or if an inter-
ruption is made when each signal is not active, an error display is
made. 
The above check is repeated in four cycles. 
• Data transfer check 
The loop back data (256 bytes) of 00H~0FFH are used for the data
transfer check. The baud rate is set to 38400BPS. 
•  Timer check (RS232 on board timer)
Before performing the data transfer check, set the timer to RCVDT
start and 5ms. Then perform the following procedure. 
*
During execution of the data transfer check, TRQ- must not be gen-
erated.
*
After 5ms from completion of the data transfer check, TRQ- must
be generated.
2
Display
RS232 I/F Diagnostic
CHANNEL Check
CH1 = exist!
Display when the channel exists
CH2 = exist!
CH3 = none!
Display when the channel doesn’t exist
CH4 = none!
CH5 = none!
CH6 = none!
CH7 = exist!
CH8 = exist!
S1-1
S1-2
S1-3
CHANNEL
0
0
0
Invalid
0
0
1
CHANNEL 1: Do not set this
(Reserved for 
standard RS)
0
1
0
CHANNEL 2: Do not set this 
(Reserved for noncontact
clerk setting)
0
1
1
CHANNEL 3
1
0
0
CHANNEL 4
1
0
1
CHANNEL 5
1
1
0
CHANNEL 6:
1
1
1
CHANNEL 7: Do not set this
(Reserved for 
internal printer)
S1-4
S1-5
S1-6
CHANNEL
0
0
0
Invalid
0
0
1
CHANNEL 1: Do not set this
(Reserved for
standard RS)
0
1
0
CHANNEL 2: Do not set this 
(Reserved for noncontact
clerk setting)
0
1
1
CHANNEL 3
1
0
0
CHANNEL 4
1
0
1
CHANNEL 5
1
1
0
CHANNEL 6:
1
1
1
CHANNEL 7: Do not set this
(Reserved for 
internal printer)
ERn
RSn
DRn
CIn
CDn
CSn
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
RS232 CH1 Check
ER-DR
:
ERROR!!
UP-3301VS
DIAGNOSTICS SPECIFICATIONS
– 28 –
All the contents of an error must be displayed.
3
Terminating procedure
Press the Touch panel to terminate the check. 
3) CH3 Check
1
Check content
The check procedure, the display, and the terminating procedure
are the same as the CH1 Check. 
4) CH4 Check
1
Check content
The check procedure, the display, and the terminating procedure
are the same as the CH1 Check. 
5) CH5 Check
1
Check content
The check procedure, the display, and the terminating procedure
are the same as the CH1 Check. 
6) CH6 Check
1
Check content
The check procedure, the display, and the terminating procedure
are the same as the CH1 Check. 
7) CH8 Check
1
Check content
The check procedure, the display, and the terminating procedure
are the same as the CH1 Check. However, set the baud rate as
115200BPS.
3-7. Liquid Crystal Display Diagnostics
The UP-3301 LCD display is checked. 
The test program displays the patterns in the following sequence. Every
time the Touch panel is pressed, the next pattern is displayed. When
the Touch panel is pressed at the final pattern the display to terminate
the check.
1) Liquid Crystal Display Check 
1
Check content
The test patterns are displayed in the following sequence. When the
Touch panel is pressed, the next pattern is displayed. 
i.
Black and white pattern at 1 dot pitch
ii.
Reversed pattern of the above (i)
iii. Vertical stripe pattern at 1 dot pitch
iv. Reversed pattern of the above (iii)
v.
Horizontal stripe pattern at 1 dot pitch
ERROR 
No.
ERROR display
ERROR content
1
ER-DR:ERROR
ER-DR LOOP ERROR
2
ER-CI:ERROR
ER-CI LOOP ERROR
3
RS-CD:ERROR
RS-CD LOOP ERROR
4
RS-CS:ERROR
RS-CS LOOP ERROR
5
CI INT:ERROR
CI interruption is not made.
6
CD INT:ERROR
CD interruption is not made.
7
CS INT:ERROR
CS interruption is not made.
8
TXEMP:ERROR
TXEMP is not set.
9
TXEMP INT:ERROR
TXEMP interruption is not made.
10
TXRDY:ERROR
TXRDY is not set.
11
TXRDY INT:ERROR
TXRDY interruption is not made.
12
RCVRDY:ERROR
RCVRDY is not set.
(Reception enabled. TR-Q is gener-
ated during data transfer check)
13
R C V R D Y
INT:ERROR
RCVRDY interruption is not made.
14
SD-RD:ERROR
SD-RD LOOP ERROR
(DATA ERROR)
15
SD-RD:ERROR
S D - R D   L O O P   E R R O R   ( D A T A
ERROR, FRAMING ERROR, etc.)
16
TIMER:ERROR
TIMER ERROR (TMRQ is not set
after completion of data transfer
check.)
17
TIMER INT:ERROR
TRQ-1 interruption is not made.
UP-3301VS
DIAGNOSTICS SPECIFICATIONS
– 29 –
vi. Reversed pattern of the above (v)
vii. Sixteen patterns of gradation ranging from black to white are dis-
played from left to right of the screen.
viii. 16-color bars are displayed.from left: black, blue, green, cyan, red,
magenta, brown, white, gray, light blue, light green, light cyan, light
red, light magenta, light yellow, and light white
ix. The outermost peripheral of the LCD's active area is displayed in
one-dot line.
White raster test
x.
"H" pattern. "H" is displayed in 80 digits and 25 lines. The 25th line
only has 39 digits of "H."
3
Terminating procedure
Press the Touch panel at the final pattern, terminate the check.
3-8. Rear Display Diagnostics
The rear display UP-I16DP or option display UP-P16DP is checked.
The test program displays the following patterns. When the Touch
panel is pressed, the display returns to the diagnostics menu.
1) Rear Display Check 
1
Check content
The display test of the rear display is performed.
The test patterns are displayed in the following sequence. When the
Touch panel is pressed, the next pattern is displayed.
i.
The test pattern below is displayed.
ii.
The test pattern with all the elements ON is displayed.
2
Display
3
Terminating procedure
Press the Touch panel to turn off all the elements of the rear dis-
play.
3-9. TCP/IP Stack Network Diagnostics
Performing the TCP/IP STACK test.
To perform this test, the following configuration is required.
• UP-3301
•  10BASE-T cable (only for data transmission test)
• HUB (only for LOOPBACK test and data transmission test when
using satellites.)
The following menu is displayed. Touch the key of the operation you
want to execute. After the individual program is completed, the screen
returns to this menu. Press Cancel key to return to the Diag Main menu.
Blac
k
Blue
Green
Spring green
Red
M
agenta
Yellow
White
Slate gray
Cyan
Spring green
Light cyan
Salmon
Light magent
a
Light yellow
Light white
HHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHH
HHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHH
HHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHH
HHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHH
HHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHH
HHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHH
HHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHH
HHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHH
HHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHH
HHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHH
HHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHH
Rear Display Check
0  1  2  3  4  5  6  7  8  9  ;  A  a  B  b  C
0.  1.  2.  3.  4.  5.  6.  7.  8.  9.  -.
  ,    ,    ,    ,    ,    ,    ,    ,    ,    ,   ,
ALPHA DISPLAY:
7-SEG DISPLAY:
8.  8.  8.  8.  8.  8.  8.  8.  8.  8.  8.
  ,    ,    ,    ,    ,    ,    ,    ,    ,    ,    ,
7-SEG DISPLAY:
ALPHA DISPLAY:
SELF Check
LOOPBACK Check
Cancel
TCP/IP STACK Network Diagnostics
MAC ADDR&FIRM Ver. Read
MAC ADDR&FIRM WRITE
DATA Trans. (MA)
DATA Trans. (SA)
UP-3301VS
DIAGNOSTICS SPECIFICATIONS
– 30 –
1) SELF Check
1
Check content
The diagnostics is built in the FlashROM of the TCP/IP is executed
in sequence and the result is displayed.
i.
Executes the FLASH MEMORY TEST command and displays
the result.
ii.
Executes the SRAM TEST command and displays the result.
iii. Executes the DUALPORT-RAM TEST command and displays
the result.
iv. Executes the INTERRUPT TEST command and displays the
result.
The description of each error status is shown below.
2
Display
3
How to terminate
Press the Touch panel to terminate.
2) LOOPBACK Check
1
Check content
Connect the RJ45 connector and the hub with a straight cable and
execute the LOOPBACK TEST command to perform a 1 packet
transmission.
2
Display
3
How to terminate
Press the Touch panel to terminate.
3) MAC ADDRESS & FIRM Ver. read Check
1
Check content
Reads the MAC Address and the firmware version and displays the
content.
2
Display
3
How to terminate
Press the Touch panel to terminate.
4) MAC ADDRESS & FIRM Write
1
Operation content
Write MAC Address and the firmware. 
(operation procedure)
• Install EPROM in ROM socket of TCP/IP and set IPL switch of
TCP/IP to "program rewriting mode".
• Power on the UP-3301, then execute the MAC ADDR&FIRM
WRITE diag.
•  Enter three sets of three digits decimal from numeric key of touch
panel, and touch the ENTER key.
• Write the MAC ADDRESS of total 6 byte, which is comprising
SHARP maker code (08, 00, 1F) and the hexadecimal digits con-
verted from three numbers entered with keyboard, into dual port
RAM (800000H~)
• Turn the power off and remove the EPROM from the ROM
socket of the TCP/IP, then set the IPL switch to "normal MODE".
•  Power on the main unit.
Input: DUAL PORT RAM (80000H~)
MAC ADDRESS (XX,YY,ZZ are in hexadecimal converted from
decimal.)
Output: DUAL PORT RAM (800800H~)
• Rewriting
•  When terminating (the same when a copy is skipped on the first
verify.)
•  When an error is terminated.
2
Display 
b7: Reserved ("0" is always displayed.) 
b6: Reserved ("0" is always displayed.)
b5: Reserved ("0" is always displayed.)
b4: Reserved ("0" is always displayed.)
b3: HR_RST :  In case that /INTHR can not be reset, "1" is set.
b2: HR_ACK : In case that /INTHR is not received within 10ms,
"1" is set.
b1: HW_RST : In case that /INTHR can not be reset, "1" is set.
b0: Reserved ("0" is always displayed.)
SELF Check
FLASH : PASS (or ERROR)
SRAM : PASS (or ERROR)
XXXXXXXX : XX : XX
address and data are displayed 
    when an error occurs.
DPRAM : PASS (or ERROR)
XXXXXXXX : XX : XX
address and data are displayed 
    when an error occurs.
INTERRUPT : PASS (or ERROR)
XXXXXXXX
data is displayed when an error 
    occurs.
LOOPBACK Check
LOOPBACK : PASS (or ERROR)
LOOPBACK ERROR 
Displays when an error occurs.
LAN ERROR
Displays when an error occurs.
MAC ADDR&FIRM Ver.Read
MAC ADDRESS :
XX XX XX XX XX XX
Displays 6 BYTE information
FIRMWARE VERSION :
XXXXXXXX
Displays 10 digits.
08 00 1F XX YY ZZ
I
P
L
0
0
-
0
7
0
0
I
P
L
0
0
-
0
7
O
K
I
P
L
0
0
-
0
7
N
G
MAC ADDR&FIRM Write
MAC ADDRESS :
AAA BBB CCC
Input with keyboard in decimal.
08 00 1F XX YY ZZ
Displays 6 BYTE in hexadecimal.
TCP/IP FIRM CHANGE :
IPL 00-07    XX (XX : 00~07 OK or NG)