UP-3301VS
DIAGNOSTICS SPECIFICATIONS
– 31 –
To enter numbers, the numeric key panel is displayed in the lower
part of the screen. 
When the IPL switch is not in the writing MODE, the following mes-
sage is displayed.
3
How to terminate
Press the Touch panel to terminate.
5) Data Transmission Check
Data transmission is checked in the system already established. The
system is composed of one master machine and a max of 63 satellite
machines. 
Note when starting the test:
•  When checking the set in which the LAN setting has been completed,
disable the LAN setting before starting this check.
• When testing the system already established, disconnect the LAN
cable of the sets not subject to test, or disable the LAN setting. Leav-
ing LAN enabled may cause data to be destroyed.
• The transmission test setting must be performed after disabling the
LAN setting of all the sets in the system. For the transmission check
setting, first, set the satellite machines, then set the master machine.
UP-3301 DIAG uses private IP address. This DIAG assigns Private IP
addresses to 64 terminal numbers to simplify the test as shown below.
When performing data transmission check, be sure to physically discon-
nect other network where these IP addresses are set. 
TERMINAL NO.1 = 192.168.0.1
TERMINAL NO.2 = 192.168.0.2
. . . . .
TERMINAL NO.63 = 192.168.0.63
TERMINAL NO.64 = 192.168.0.64
1
How to set
i.
Satellite machine setting
In the menu screen, select "Data Trans. (SA)". Following screen
appears. Numeric key panel to enter numbers is displayed in
the lower part of the screen.
Press the terminal No. (2 digits number between 1~64) of the
machine to be checked and touch the Enter key.
The following screen appears.
ii.
Master machine setting
In the menu screen, select "DATA Trans. (MA)". The following
screen appears. Numeric key panel to enter numeric character
is displayed in the lower part of the screen.
Press the terminal No.(2 digits number among 1~64) of the
machine to be checked and Enter key. 
The following screen appears. The numeric key panel to enter
numeric characters is displayed in the lower part of the screen.
Press the terminal No. (2 digits number among 1~64) of the sat-
ellite machine to be connected to the test machine. The
numeric key panel to enter numeric characters is displayed in
the lower part of the screen.
When checking with two or more satellite machines connected,
repeat the entry for the terminal No. (2 digits, 1~64) and touch
ENTER key. To execute the checking, touch the ENTER key
without entering the terminal No. You can also enter the termi-
nal No. with range designating function without entering all ter-
minal No. After entering the first terminal No. and last terminal
No. of the satellite machine, touch ENTER key. For example,
when you want to enter the terminal No. 5~63 of the satellite
machine, touch "0515" and ENTER key.
The following screen appears.
Do not assign the same terminal No. to different machines
(master/satellite).
When you designate terminal No. with range designating func-
tion, the terminal No. used in the master machine is excluded
from the designated terminal number of the satellite machine.
After completing the above setting, data transmission test
starts.
MAC ADDR&FIRM Write
CHANGE IPL SW!!
Data Trans. (SA)
INPUT SA T-NO :
Enter one number out of 1 to 64. 
ENTER
0
CANCEL
4
7
2
1
5
8
3
6
9
CL
Data Trans. (SA)
INPUT SA T-NO : XX
Displays the entered terminal numbers 
    of the satellite machine.
DATA SEQ NO. : 0000
Data Trans. (MA)
INPUT MA T-NO : 
Enter one number out of 1 to 64.
Data Trans. (MA)
INPUT MA T-NO : XX
Displays the entered terminal number of 
    the master machine.
INPUT SA T-NO : 
Enter one number out of 1 to 64.
Data Trans. (MA)
INPUT MA T-NO : XX
Displays the entered terminal 
    number of the master machine.
INPUT SA T-NO : XX (or XXXX)
Displays the entered terminal
    numbers of the satellite machine.
Data Trans. (MA)
INPUT MA T-NO : XX
Displays the entered terminal number of 
    the master machine.
INPUT SA T-NO : XX
Displays the entered terminal number of 
    the satellite machine.
 XX XX XX XX XX XX (or XXXX)
When multiple terminal number 
of the satellite machine are 
entered, all of them will be dis-
played.
DATA SEQ.NO. : 0000
UP-3301VS
DIAGNOSTICS SPECIFICATIONS
– 32 –
2
 Check content
i.
Data composed of 2 byte sequence No. and 254 byte AAH data
in the following format are transmitted from the master machine
to the satellite machine. The master machine displays the
sequence No. 
Test data format (1 packet : 256 byte)
ii.
The satellite machine sends back the received data to the mas-
ter machine. The satellite machine displays the received
sequence No.
iii. After receiving the data, the master machine checks the
sequence No. and 254 byte AAH data. In case of an error, the
error code is displayed and the test is completed. If multiple sat-
ellite machines are connected, the step i and ii above operation
are repeated. If data transmission with all the satellite machines
are normally completed, the master machine increments the
sequence No.
Repeat step i and iii. 
3
 Error display 
Description of the error codes are shown below. (comply with TCP/IP
HDNLER)
4
 How to terminate
Touch PANEL key to terminate the check.
3-10. Magnetic Card Reader Diagnostics
Read check of the optional UP-E12MR2 is performed.
The test program reads the magnetic card of ISO 7811/1-5 standard
and displays the data. When the Touch panel is pressed, the display
returns to the diagnostics menu.
1) Magnetic Card Reader Check
1
Check content
The test program reads tracks 1 and 2 of the magnetic card of ISO
7811/1-5, and displays the data in ASCII code. 
2
Display
XXXXX shows the data read by the MCR. Incase of an error, the
error code is displayed as shown below.
3
Terminating procedure
Press the Touch panel to terminate the check. 
3-11. Drawer Diagnostics
This diagnostics is used to check the drawer open and sensors. 
The following menu is displayed. Press the position of the operation you
want to perform to execute individual Diag programs.
Pressing the CANCEL key returns the screen to the Diag MAIN menu.
Data Trans. (MA)
INPUT MA T-NO : XX
INPUT SA T-NO : XX
 XX XX XX XX XX XX
 XX XX XX XX XX XX (or XXXX)
DATA SEQ.NO. : 0000
TCP/IP ERROR : XX 
Displays ERROR CODE.
01
Improper command (except when transmission)
02
No data received.
03
Received data present. 
Received data remained.
04
Remote machine not ready (when sending)
"NTDY" is sent back because the remote machine is not
ready for reception.
05
Received buffer full (when sending)
The controller’s receive buffer of the remote machine is full.
06
Re-send error (when sending)
Excess retrying (5 times) for no response
07
Collision error (when sending)
In a collision circumstance, excess in retry times (16 times) for
re-collision after a random (0~255ms) interval.
08
Line busy time out. 
Transmission can not be made due to the communications
between multi-station, and it causes time out in data send wait
time.
09
Excess of allowed receive size (when receiving)
Received buffer size is insufficient.
0A
Hardware error
Improper interface (LAN controller etc.)
XX
XX
AA
AA
AA
AA
AA
AA
256
255
254
5
4
3
2
1
Byte
XXXX
AA
: Sequence No. (2byte: 4digits of binary decimal numbers)
: Transmission data (AAH) x 254 bytes
MCR (Magnetic Card Reader) Check
TRACK1:
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
xxxxxxxxxx
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
TRACK2:
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
Magnetic Card Reader Check
TRACK1:BUFFEREMPTY
- Displayed when TRACK1 empty
code is sent back.
TRACK1:MCRERROR
- Displayed when  TRACK1 error
code is sent back.
TRACK2:BUFFEREMPTY
- Displayed when TRACK2 empty
code is sent back.
TRACK2:MCRERROR
- Displayed when  TRACK2 error
code is sent back.
Drawer 1 Check
Cancel
Drawer Diagnostics
Drawer 2 Check
UP-3301VS
DIAGNOSTICS SPECIFICATIONS
– 33 –
1) Drawer 1 Check
1
Check content
The solenoid of drawer 1 is turned on, and the drawer open sensor
value is sensed at every 100ms, and the state is displayed.
2
Display
3
Terminating procedure
Press the Touch panel to terminate the check. 
2) Drawer 2 Check
1
Check content
The solenoid of drawer 2 is turned on, and the drawer open sensor
value is sensed at every 100ms, and the state is displayed.
The display and the terminating procedure are the same as Drawer
1 Check. 
3-12. Printer Diagnostics
I/F loopback and printing tests of the built-in printer are performed.
The following menu appears. Press the name of the test you want to
perform to execute its Diag program. When the Diag program is termi-
nated, the screen returns to the Printer Diagnostics menu. Pressing the
CANCEL key returns to screen to the Diag Menu.
1) Loop Back Check
1
Check content
A LOOPBACK test on the built-in printer (UP-T80BP) interface
(logic channel 7 of RS232) is performed and the result is displayed.
The test itself is the same as that for the RS232. The difference in
test specifications is as follows: The loopback signals are for ER-
DR, RS-CS, TXD-RXD only and the following LOOPBACK-Connec-
tors are required.
Wiring diagram of loopback connectors 
(UKOG-2356BHZZ)
2
Indication
The indication is the same as that for RS232 DIAGNOSTICS.
3
End
Press the PANEL to end the program.
2) Printer Print Check
1
Check
Send the signal to generate a receipt (by DIAG COMMAND) to the
UP-T80BP.
3-13. EFT Diagnostics
Check of the EFT (ER-02EF) is performed.
Select the EFT Diag, and turn of  the power supply after that.
1) EFT Check
Set all the bits of DIPSW1 to “off”, then turn off the power supply of main
unit. The EFT check is performed automatically.
1
Check content
i.
Executes the LOOP BACK TEST to EFT connector about ER-
DR, ER-CT and RS-CS signals.
ii.
Executes the DIPSW1 check by turning on the 1-8 bit of
DIPSW1 in order.
iii. When normal, SUM CHECK of EFT ROM is performed auto-
matically, and WRITE/READ check is performed to RAM.
2
Display (Normal)
3
Display (Error)
4
End
Pless the PANEL to end the program.
Drawer1 Check
Drawer Open Sensor
: OPEN (or CLOSE)
Loop Back Check
Printer Print Check
Cancel
Printer Diagnostics
1pin
2pin
3pin
4pin
5pin
6pin
7pin
8pin
9pin
CD
RD
SD
ER
GND
DR
RS
CS
CI
EFT Diagnostics
DIAGO (SELF TEST) : OK
VHI27040R
**
1
*
: OK
256K SRAM
: OK
In Loop Back Error
ER-DR LOOP ERROR
ER-CI LOOP ERROR
ER-CS LOOP ERROR
In Self Test Error
DIP SW ERROR
In Self Test Error
VHI27040R
**
1
*
: ERROR
256K SRAM
: ERROR
UP-3301VS
CIRCUIT DESCRIPTION
– 34 –
CHAPTER 7. CIRCUIT DESCRIPTION
1. Hardware block diagram
Drawer x 2
RS232 x 2
CPU
H8/510
MPCA8
Customer display
MCR
SRAM
2MB
OPC2
EXT.SLOT
(80pin x 2)
RAMCN
(72pin)
CKDC9
VCC
+24V
+12V
LCD
640 x 480 dots
DRIVER
DRIVER
DRIVER/
RECEIVER
VGA
CONTROLLER
MN89303A
BRIGHTNESS
CONTROL
INVERTER
CONTRAST
ADJUSTMENT
POWER SUPPLY
VRAM
(DRAM 512K)
UPE10IN
Compatible
FLASH
RAM
4MB
(NOR)
PRINTER (UP-T80BP)
Clerk SW
TCP/IP
TOUCH
CONTROLLER
x 2
Page of 96