SERVICE PRECAUTION
– 15 –
4.
4.1  UP-3301 IPL
No
Procedure on P.C. side
No
Procedure on UP-3301 side
1
Install “UTL33.EXE” on the P.C.
2
Turn OFF the power.
3
Select “IPL Mode”.
Set the “IPL Switch” of UP-3301 to “ON”.
4
Turn ON the power.
5
Starting of “IPL Mode”.
The UP-3301 displays
“IPL from Serial I/O”
6
Connect P.C. and UP-3301 via RS232. 
7
Execute “UTL33.EXE” on P.C.
Operation:
>UTL33  3301_1.ROM  3301_2.ROM
(“3301_1.ROM” and “3301_2.ROM” are file name of S-type
ROM object.)
8
Program data is sent to UP-3301 automatically.
8
Program data is received from P.C. automatically.
The UP-3301 displays
9
“UTL33.EXE” is completed.
P.C. shows
“Completed.”
9
The UP-3301 displays
“Completed.”
10
Turn OFF the power.
11
Select “Normal Mode”.
Set the “IPL switch” to “OFF”.
12
Execute the “Service Reset” on UP-3301.
IPL SW
ON
IPL from IR
Connected IRDA 115200
21 22 23 24 25 26 27 28
IPL from Serial I/O
Connected IRDA 115200
21 22 23 24 25 26 27 28
29 2A 2B 2C 2D 2E 2F
Completed.
IPL from Serial I/O
Connected IRDA 115200
30 31 32 33 34 35 36 37
38 39 3A 3B 3C 3D 3E 3F
Completed.
UP-3301VS
SERVICE PRECAUTION
– 16 –
4.2  UP-T80BP LOGO
4.3  UP-T80BP IPL
No
Procedure on P.C. side 
No
Procedure on UP-3301 side
1
Install “UTL33.EXE” on the P.C.
2
Enter the SRV mode. Then turn OFF the power or UP-3301.
3
While pressing the On-Line key, tum ON the power of UP-3301.
Keep pressing the On-Line key, and then press the Feed key
also. (Don’t move a finger from the On-line key.)
4
UP-T80BP enters into LOGO mode.
UP-T80BP prints out 
****************
”.
5
Go  into  “UP-T80BP Utility mode”.
Select “6 UP-T80BP Utility” in SRV mode.
6
Starting of “UP-T80BP Utility mode”.
UP-3301 shows
7
Connect P.C. and UP-3301 via RS232 (CH2). 
8
Execute “UTL33.EXE” on P.C.
Operation:
>UTL33  LOGO.BMP
(“LOGO.BMP” is a file name of Bit-Map image.)
9
Program data is sent to UP-3301 automatically.
9
Program data is received from P.C. automatically. 
10
“UTL33.EXE” is completed.
P.C. shows
“Completed.”
10
UP-3301 shows
“Completed.”
And UP-T80BP prints out the LOGO image.
11
Touch “OK” button.
12
Touch “EXIT” button.
13
Turn OFF the power of UP-3301.
14
Execute “Master Reset” on UP-T80BP.
No
Procedure on P.C. side
No
Procedure on UP-3301 side
1
Install “UTL33.EXE” on the P.C.
2
Turn OFF the power of UP-3301.
3
Select “IPL Mode” on UP-T80BP.
Set the Bit 1 of DipSwitch 2 to “ON” to enter “IPL Mode”.
4
While pressing both the Feed key and the On-Line key, turn ON
the power of UP-3301.
The ERROR Lamp and the On-line Lamp of UP-T80BP is
blinking.
UP-T80BP Utility
EXIT
UP-T80BP Utility
Normal mode
EXIT
UP-T80BP Utility
Normal mode
EXIT
Complete
OK
IPL SW
ON
IR Filter
UP-3301VS
SERVICE PRECAUTION
– 17 –
<Usage of “UTL33.EXE”>
“UTL33.EXE” is a utility program on P.C. - a program that sends the
application program data of UP-3301, the image data of the Logo stamp
of UP-T80BP or the application program data of UP-T80BP in order to
replace them.
Syntax
UTL33  [-Fn]  [-Cn]  filename [filename ...]
Parameter
filename
Specifies the name file which you want to send.
Switches
-Fn
Specifies the function. Valid values for n are in the range 1 through 3.
1: UP-3301 IPL
2: UP-T80BP LOGO STAMP
3: UP-T80BP IPL
Normally, UTL33.EXE takes the suitable function automatically.
If the automatic selection does not work correctly, please use this
switch.
-Cn
Specifies the number of the serial (COM) port. Valid values for n are
in the range 1 through 2.
The default value is 1 (COM1).
Example
For UP-3301 IPL.
UTL33  3301_1.ROM  3301_2.ROM
For UP-T80BP LOGO STAMP (To use COM2).
UTL33  -C2  LOGO.BMP
For UP-T80BP IPL (To use the switch “-F”).
UTL33  -F3  80BP.ROM.
5
UP-T80BP enters into IPL mode when the Feed key is pressed.
(UP-T80BP clears the application program which is in its own
flash ROM.)
The ERROR Lamp is blinking and the On-Line Lamp is turned off.
6
UP-T80BP waits the application program data.
The ERROR Lamp is turned off and the On-Line Lamp is
turned on.
7
Enter “UP-T80BP Utility” mode.
Select “6 UP-T80BP Utility” in SRV mode
8
Starting of “UP-T80BP Utility” mode.
UP-3301 shows
9
Connect P.C. and UP-3301 via RS232 (CH2).
10
Execute “UTL33.EXE” on P.C.
Operation:
>UTL33  T80BP.ROM
(“T80BP.ROM” is a file name of S-type object.)
11
Program data is sent to UP-3301 automatically.
11 
Program data is received from P.C. automatically.
The On-line Lamp of UP-T80BP starts blinking.
12
“UTL33.EXE” is completed.
P.C. shows
“Completed.”
12
UP-3301 shows
“Completed.” 
The On-line Lamp of UP-T80BP stops blinking.
13
Touch  “OK” button.
14
Touch  “EXIT” button.
15
Turn OFF the power of UP-3301.
16
Select “Normal Mode” on UP-T80BP.
Set the Bit 1 of DipSwitch 2 to “OFF” to enter “Nomal Mode”.
17
Execute “Master Reset” on UP-T80BP.
No
Procedure on P.C. side
No
Procedure on UP-3301 side
UP-T80BP Utility
EXIT
UP-T80BP Utility
EXIT
IPL mode
IPL mode
UP-T80BP Utility
- : 1 6
Complete
OK
For UP-3301 IPL
S-type ROM object file
For UP-T80BP LOGO STAMP BMP/PCX file
For UP-T80BP IPL
S-type ROM object file
UP-3301VS
SERVICE PRECAUTION
– 18 –
5. Requirements for soldering circuit parts
To solder the following parts manually, follow the conditions described
below.
6. Note for handling of Touch panel
•  The transparency of the touch panel is vitally important. Do not place
finger prints or moisture on the surface. When handling, use clean
gloves and masks.
• For handling, do not hold the transparent area, and do not hold the
heat seal connector section to assure reliability. 
•  Do not overlay touch panels. The edge may damage the surface. 
•  Do not put a heavy object on the touch panel.
•  Do not apply strong shocks, and do not drop.
•  When attaching the protection film, carefully check that no dirt exists. 
•  To clean dirt on the surface, use a dry, soft cloth or a cloth immersed
in ethyl alcohol.
• Check that the housing does not induce any stress to the touch
panel. 
•  Be careful not to touch the touch panel with tools. 
• The heat seal section is easily disconnected. Be careful not to apply
any stress to the heat seal section when installing. 
• The touch panel is provided with an air groove to make the external
and the internal air pressure equal to each other. If water or oil is put
around the air groove, it may penetrate inside. Be careful and keep
the air groove away from water and oil. 
• Input is performed with fingers. Do not use hard objects to input
entries.
7. Note for handling the LCD assembly
•  The LCD elements are made of glass. BE careful not to expose them
to a strong mechanical shock. Use extreme care not to break them.
• If the LCD element is broken and the liquid is seeps, do not lick it. If
the liquid comes in contact with your skin or clothes, immediately
clean with soap. 
•  Use the unit under the rated conditions to prevent against damage.
•  Be careful not to drop water or other liquids on the display surface.
• The reflection plate and the polarizing plate can be easily scratched.
Be careful not to touch them with any hard object such as glass or
tweezers. Never hit, push, or rub the surface with hard objects.
• When installing the unit, be careful not to apply stress to the LCD
module. If excessive stress is applied an abnormal display or uneven
color may result. 
8. Cautions on handling connectors
When connecting or disconnecting the following connectors, follow the
procedures below.
1)
 • How to Connect or Disconnect the FFC Connector
(1) Open the slider to the unlock position
The slider will open only up to a fixed height (about 1.2mm). If you
used force to pull up the slider further, it may be damaged.
(2) Insert the FFC
Insert the FFC firmly untill the FFC hits the bottom of the connec-
tor’s insulator.
(3) Close the slider to the lock position
Insert the FFC and then push the slider downward.
PARTS 
NAME
PARTS CODE
LOCATION
CONDITIONS FOR 
SOLDERING
Ceramic 
oscillator
RCRMZ7002RCZZ
MAIN PWB: 
X1 (8M)
270°/3sec.
RCRMZ7004RCZZ
MAIN PWB: 
X2 (7.37M)
270°/3sec.
PARTS NAME
PARTS CODE
LOCATION
FFC 
CONNECTOR
QCNCW7207RC4J
MAIN PWB: CN6
TOUCH PWB: CN5
FFC 
CONNECTOR
QCNCW7183BH2F
MAIN PWB: CN1
Slider
1.2mm
UNLOCK
FFC
FFC
CONNECTOR
FFC
CONNECTOR
FFC
CONNECTOR
FFC
Slider
LOCK
Page of 96