DOWNLOAD Sharp ER-A771 (serv.man3) Service Manual ↓ Size: 2.35 MB | Pages: 77 in PDF or view online for FREE

Model
ER-A771 (serv.man3)
Pages
77
Size
2.35 MB
Type
PDF
Document
Service Manual
Brand
Device
EPOS / Service Manual
File
er-a771-sm3.pdf
Date

Sharp ER-A771 (serv.man3) Service Manual ▷ View online

ER-A771VS
SRV RESET (Program Loop Reset) and switch to SRV mode
4 – 1
CHAPTER 4. SRV RESET (Program Loop Reset) and switch to SRV mode
In the ER-A771, the following reset switch (location No. : SW1) is used
to switch to the service (SRV) mode and to reset.
SRV. RESET
Used to return the machine back to its operation state after a lock up
has occurred.
PROCEDURE
1) Turn off the AC switch.
2) Set the reset switch to "ON" position
3) Turn on the AC switch. (Wait one second)
4) Turn to "OFF" the reset switch.
5) The SRV mode is displayed as shown below.
DISPLAY:
Reset
switch
Rear side :"ON" position(Reset state)
ON
OFF
Front side :"OFF" position(Run state)
ON
OFF
RESET SW
RESET SW
SW1
ER-A771VS
MASTER RESET (All Memory Clear)
5 – 1
CHAPTER 5. MASTER RESET (All Memory Clear)
There are two possible methods to perform a master reset.
MRS-1 (MASTER RESETTING 1)
Used to clear all memory contents and return machine back to its initial
settings.
Return keyboard back to default for default kyeboard layout.
PROCEDURE
1) Turn off the AC switch.
2) Set the reset switch to "ON" position
3) Turn on the AC switch. (Wait one second)
4) While holding down MRS-1 key , turn to "OFF" the reset switch.
keyboard layout
5) Enter the password key operation
DISPLAY:
keyboard layout
6) Master reset is started.
DISPLAY:
7) After completion of the master reset, the buzzer sounds three times
and the following SRV mode display is shown.
DISPLAY:
*
MRS-1 key: The key located on Left upper corner of the key-
board.
MRS-1 Key
Password input procedure: Press the four corners of the key-board
in the sequence of a, b, c, and d.
ENTER PASSWOPRD
a
c
d
b
MASTER RESET
ER-A771VS
MASTER RESET (All Memory Clear)
5 – 2
MRS-2 (MASTER RESETTING 2)
Used to clear all memory and keyboard contents. This reset returns all
programming back to defaults.
The keyboard must be entered by hand. This reset is used if an applica-
tion needs different keyboard layout other than that supplied by a nor-
mal MRS-1.
1) Turn off the AC switch.
2) Set the reset switch to "ON" position
3) Turn on the AC switch. (Wait one second)
4) While holding down MRS-2 key , turn to "OFF" the reset switch.
keyboard layout
5) Enter the password key operation
DISPLAY:
6) Set the fixed keys in the table below. (Start from the zero "0" key,
The keys are displayed sequentially.)
DISPLAY:
[Key setup procedure]
7) Master reset is started.
DISPLAY:
8) After completion of the master reset, the buzzer sounds three times
and the following SRV mode display is shown.
DISPLAY:
*
MRS-2 key: The key located on Right upper corner of the key-
board.
Password input procedure: Press the four corners of the key-
board in the sequence of a, b, c, and d.
MRS-2 Key
ENTER PASSWOPRD
a
c
d
b
*
1: When the 0 key is pressed, the key of the key number on dis-
play is disabled.
*
2: Push the key on the position to be assigned. With this, the
key of the key number on display is assigned to that key posi-
tion.
*
3: When relocating the keyboard, the PGM 1/2 mode use stan-
dard key layout.
Key 
No.
Key 
name
Key 
No.
Key 
name
Key 
No.
Key 
name
001
"0" key
011
"00" key
021
RIGHT "
3
" key
002
"1" key
012
"000" key
022
"CANCEL" key
003
"2" key
013
Decimal point " • " key
023
"ENTER" key
004
"3" key
014
"CL" key
024
"TL" key
005
"4" key
015
"
y
" key
006
"5" key
016
"SBTL" key
007
"6" key
017
"MODE" key
008
"7" key
018
UP " 
2
 " key
009
"8" key
019
DOWN " 
4
 " key
010
"9" key
020
LEFT "
1
" key
ENTER 0        KEY
0
Free key
0
Disable
MRS-2
executed
Key
position set
Setup
complete
MASTER RESET
ER-A771VS
DIAGNOSTICS SPECIFICATIONS
6 – 1
CHAPTER 6. DIAGNOSTICS SPECIFICATIONS
CONTENTS
1.
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1
2.
System configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1
2-1. Test system  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1
3.
Diagnostics  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1
1) Master reset procedure . . . . . . . . . . . . . . . . . . . . . . . . . 6-1
2) Program reset (service reset) procedure. . . . . . . . . . . . 6-1
3-1. Execution of diagnostics. . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1
3-2. RAM Diagnostics  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2
1) Standard RAM Check . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2
2) UP-S02MB2 Check   . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2
3-3. ROM & SSP Diagnostics  . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3
1) Standard ROM Check . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3
2) SERVICE ROM Check  . . . . . . . . . . . . . . . . . . . . . . . . . 6-3
3) SSP Check  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4
3-4. Timer & Keyboard Diagnostics . . . . . . . . . . . . . . . . . . . . . . 6-4
1) Timer Check  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4
2) Keyboard Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4
3-5. RS232 I/F Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4
1) CHANNEL Check  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4
2) CH1 Check  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-5
3) CH3 Check  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-5
4) CH4 Check  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6
5) CH5 Check  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6
6) CH6 Check  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6
7) CH8 Check  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-6
3-6. Liquid Crystal Display Diagnostics . . . . . . . . . . . . . . . . . . . 6-6
1) Liquid Crystal Display Check  . . . . . . . . . . . . . . . . . . . . 6-6
3-7. Rear & Pole Display Diagnostics . . . . . . . . . . . . . . . . . . . . 6-7
1) Rear & Pole Display Check . . . . . . . . . . . . . . . . . . . . . . 6-7
3-8. TCP/IP Stack Network Diagnostics  . . . . . . . . . . . . . . . . . . 6-7
1) SELF Check  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7
2) LOOPBACK Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7
3) MAC ADDRESS & FIRM Ver. Read Check  . . . . . . . . . 6-8
4) MAC ADDRESS & FIRM Write . . . . . . . . . . . . . . . . . . . 6-8
5) Data Transmission Check . . . . . . . . . . . . . . . . . . . . . . . 6-8
3-9. EFT Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-10
3-10. Magnetic Card Reader Diagnostics . . . . . . . . . . . . . . . . . 6-10
1) Magnetic Card Reader Check . . . . . . . . . . . . . . . . . . . 6-10
3-11. Drawer Diagnostics  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-10
1) Drawer 1 Check. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-10
2) Drawer 2 Check. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-10
3-12. Contactless CLERK DIagnostics  . . . . . . . . . . . . . . . . . . . 6-11
1) Self Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-11
2) Key Read Test. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-11
3) FIRM Write  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-11
1. General
This diagnostics program is used as a simplified check of the ER-A771
series operations in servicing.
The diagnostics program is built in the standard ROM.
2. System configuration
2-1. Test system
ER-A771 only
3. Diagnostics
Starting the diagnostics
This diagnostics program is written in the external ROM and executed
by the CPU (H8/510). To operate this program, the following conditions
must be satisfied.
1
The power for the logic system is proper.
(+5V, VCKDC, POFF, +20V)
2
The input/output pins and the internal logic of the CPU are normal.
In addition, CKDC9, MPCA8, the system bus, and the standard
ROM/RAM are normal.
To start the machine for the first time, perform the master reset. 
In order to add an option unit when the machine is normally operating,
perform the program reset. 
When adding the memory option, a master reset is required.
1) Master reset procedure
1
Turn off the power.
2
Set the CKDC reset switch to RESET position.
3
Turn on the power. 
4
While pressing the specified key, set the CKDC reset switch to the
normal position. 
2) Program reset (service reset) procedure
1
Turn off the power. 
2
Set the CKDC reset switch to RESET position. 
3
Turn on the power. 
4
Set the CKDC reset switch to the normal position. (Do not press any
key.)
3-1. Execution of diagnostics
To start the diagnostics, select "DIAGNOSTICS" with the cursor in the
menu selection in SRV mode, and press the enter key.
The DIAG MAIN MENU is started and the following menu screen is dis-
play. The cursor position is highlighted. Use 
2
 key and 
4
 key to move
the cursor. Move the cursor to the process you desire and press the
enter key. The selected individual diagnostics program is executed.
When the individual diagnostics program is completed, the display
returns to the menu screen. To terminate the diagnostics, press the
CANCEL key. Then the display returns to the SRV mode menu screen.
ER-A771
Page of 77
Display

Click on the first or last page to see other ER-A771 (serv.man3) service manuals if exist.