43
Part3 FOR THE MANAGER
PRIOR TO PROGRAMMING
Procedure for programming
1.
Check to see whether a paper roll is present in the machine.  If there is not enough
paper on a roll, replace it with a new one (refer to “Replacing the Paper Roll” on
page 76 for the replacement).
2.
Put the manager key in the mode switch and turn it to the PGM position.
3.
Program necessary items into the cash register.
Every time you program an item, the cash register will print the setting.  Please refer to print samples in each
section.
4.
If necessary, issue programming reports for your reference.
• On the key operation example shown in the programming details, numbers such as “22102007”
indicates the parameter which must be entered using the corresponding numeric keys.
• Asterisks in the tables shown in the programming details indicate default settings.
Entering character codes with numeric keys on the keyboard
For entering numerals, letters or symbols, enter a character code using numeric keys and press the numeric key 
:
.
For the character codes, please refer to the alphanumeric character code table on the next page.  By doing this,
you can program characters other than those on the key tops.  For entering numerals and letters using character
keys, refer to “Using character keys on the keyboard” on page 14.
• Double-size characters can be made by entering the character code 253 or pressing the 
W
key.  “_” lights up
at the DC position of the display when double-size characters entry is selected as shown in the operator
display example below.
• All three digits of the character code MUST be entered (even if it starts with zero).
To program the word “SHARP” in double-size characters
253
:
083
:
072
:
065
:
082
:
080
:
S
H
A
R
P
REG
OPX/Z
MGR
PGM
X1/Z1
X2/Z2
 A113_3 FOR THE MANAGER  06.9.11 6:39 PM  Page 43
44
Alphanumeric character code table
*(DC): Double-size character code
Code
001
002
003
004
005
006
007
008
009
010
011
012
013
014
015
016
017
018
019
020
021
022
023
024
025
026
027
028
029
030
031
032
033
034
035
036
037
038
039
040
041
042
043
044
045
Character
á
â
ê
î
ì
í
ô
ó
û
ú
œ
u
ú
o
ó
¨




U
Ú
O
Ó
(space)
!
#
$
%
&
(
)
+
,
-
Code
046
047
048
049
050
051
052
053
054
055
056
057
058
059
060
061
062
063
064
065
066
067
068
069
070
071
072
073
074
075
076
077
078
079
080
081
082
083
084
085
086
087
088
089
090
Character
.
/
0
1
2
3
4
5
6
7
8
9
:
;
<
=
>
?
@
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
Code
091
092
093
094
095
096
097
098
099
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
Character
Ä
Ö
Ü
^
_
 
a
b
c
d
e
f
g
h
i
j
k
l
m
n
o
p
q
r
s
t
u
v
w
x
y
z
{
|
}
ß
¢
!!
1
2
3
4
1/2
F
T
Code
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
177
178
180
181
182
183
184
185
186
187
188
189
190
191
192
Character
F
T
ç
°
¿
ù
à
Æ
ø
Å
¤
é
è
Pt
i
Ñ
ò
£
¥
°
Á
Í
A
a
E
e
I
i
U
u
N
n
C
S
C
▲▲
´´
´´
´´
´´
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
253
I
G
S
G
g
K
k
L
l
Z
D
d
C
c
P
e
s
c
z
y
u
n
r
 
§
Ø
]
[
ä
ö
ü
æ
å
É
ñ
*(DC)
.
.
.
.
..
.
.
.
.
.
.
Code Character
 A113_3 FOR THE MANAGER  06.9.11 6:39 PM  Page 44
45
Part
3
 FOR THE MANAGER
Part
2
Part
1
AUXILIARY FUNCTION PROGRAMMING
The cash register provides miscellaneous keys such as 
%
&
-
r
R
V
X
Y
c
b
and
A
.
Rate for 
%
&
and 
V
*:  Rate
0.00 — 100.00 (% rate)
0.000000 — 999.999999 (Currency exchange rate)
You must use a decimal point when setting fractional rates.
Amount for 
-
Discount amount
200
-
A
Print
Key operation example
Discount amount (max. six digits)
A
-
To program zero
Percent rate
Currency 
exchange rate
10 
P
25
%
P
939938
V
A
Print
Key operation example
*Rate
or
%
V
A
&
To program another rate
To program zero
Miscellaneous Key Programming
1
 A113_3 FOR THE MANAGER  06.9.11 6:39 PM  Page 45
46
Percent rate limitation for 
%
and 
&
You can program the upper limit of percent rates for percent entries.
• Percent entries that exceed the upper limit may be overridden in the MGR mode.
• 10.00% can be entered as
10
or  
10P00
.  The 
P
key is needed only
for fractional entry.
Function parameters for 
%
&
and 
-
*: Item:
Selection:
Entry:
A
+/- sign
+ (premium) sign
0
- (discount) sign*
1
B
Item % / Item 
_
Allow*
0
Disallow
1
C
Subtotal % / Subtotal 
_
Allow*
0
Disallow
1
D
Entry digit limit for discount key
0-8 (default:8)
When programming for percent keys, always enter 0 for D.
+/- sign
• Programming of the +/- sign assigns the premium or discount function for each key.
Item % / Item 
_
_
• Percent/discount calculation for the individual department and PLU/subdepartment
Subtotal % / Subtotal 
_
_
• Percent/discount calculation for the subtotals
Entry digit limit (For discount key only)
• The entry digit limit is in effect for the REG mode operations but can be overridden in the MGR mode.  The
entry digit limit is represented by the number of allowable digit for the maximum entry amount for discount
key.  When “0” is set, open price entry is prohibited.
*ABCD
or
%
@
-
A
&
To program for another key
To program “0” for all items
Percentage limit
s
29
@
15
P
00
%
A
Print
Key operation example
s
@
29
Percentage limit (0.00 -100.00%)
A
To program zero
To program for another percent key
or
% &
 A113_3 FOR THE MANAGER  06.9.11 6:39 PM  Page 46
Page of 127
Display