DOWNLOAD Sharp AY-A07B (serv.man2) Service Manual ↓ Size: 4.57 MB | Pages: 127 in PDF or view online for FREE

Model
AY-A07B (serv.man2)
Pages
127
Size
4.57 MB
Type
PDF
Document
User Manual / Operation Manual
Brand
Device
Air Conditioner
File
ay-a07b-sm2.pdf
Date

Sharp AY-A07B (serv.man2) User Manual / Operation Manual ▷ View online

ENGLISH
E-11
1
Press the ONE-HOUR OFF TIMER button.
• The remote control displays “ 
  ”.
• The orange TIMER lamp ( 
 ) on the unit will light
up.
• The unit will stop operating after one hour.
TO CANCEL
Press the CANCEL button.
• The orange TIMER lamp ( 
 ) on the unit will turn
off.
Or, turn the unit off by pressing the ON/OFF but-
ton.
• The red OPERATION lamp ( 
 ) and the orange
TIMER lamp ( 
 ) on the unit will turn off.
1
When the ONE-HOUR OFF TIMER is set, the unit will stop operating after one hour.
ONE-HOUR OFF TIMER
NOTES:
• The ONE-HOUR OFF TIMER operation has priority over TIMER ON and TIMER OFF
operations.
• When the ONE-HOUR OFF TIMER is set while the unit is not operating, the unit will
operate for an hour with the formerly set condition.
• If you wish to operate the unit for another hour before the ONE-HOUR OFF TIMER
activiates, press the ONE-HOUR OFF TIMER button again during operation.
MODE
DISPLAY MODE
FAN
1H
SWING CANCEL
TEMP.
TEMP.
FAN
TIMER
E-12
The unit will turn off automatically according to your setting.
Timer duration can be set from minimum 0.5 hours (30 minutes) to maximum 12
hours.
Up to 9.5 hours, you can set by 0.5 hours (30 minutes) increments and from 10 to 12
hours, by 1 hour increment.
TIMER OPERATION
TIMER OFF
When the TIMER OFF is set, the temperature
setting  is automatically adjusted to prevent
the room from becoming excessively hot or
too cold while you sleep. (Auto Sleep function)
1
COOL/DRY MODE:
• One hour after the timer operation begins,
the temperature setting rises 1°C higher
than the original thermostat setting.
HEAT MODE:
(only for models AY-A07BE/AY-A09BE/AY-A12BE)
• One hour after the timer operation begins,
the temperature setting drops 3°C lower
than the original thermostat setting.
TO CANCEL TIMER
TIPS ABOUT TIMER OFF OPERATION
Point the remote control at the signal receiver win-
dow on the unit.
1
Press the TIMER OFF ( 
 ) button and set
time as desired.
• The time setting will change as you to press
the button as follows,
Hold the button pressed down for fast setting.
• The orange TIMER lamp ( 
 ) on the unit will
light.
• The unit will generate a beep when it receives
the signal.
• The time setting will count down to show re-
maining time.
MODE
DISPLAY MODE
FAN
1H
SWING CANCEL
TEMP.
TEMP.
FAN
TIMER
DISPLAY MODE
FAN
1H
SWING CANCEL
Press the CANCEL button.
• The orange
TIMER lamp
 ) on the
unit will turn
off.
TO CHANGE TIMER SETTING
Press the TIMER button which you wish to
change, (TIMER OFF or TIMER ON) and
change the time setting.
0.5H
1.0H
1.5H
10H
11H
12H
Example : When you wish to
stop the operation
2.5 hours later.
ENGLISH
E-13
The unit will turn on automatically according to your setting.
Timer duration can be set from minimum 0.5 hours (30 minutes) to maximum 12
hours.
Up to 9.5 hours, you can set by 0.5 hours (30 minutes) increments and from 10 to 12
hours, by 1 hour increment.
TIMER ON
1
Point the remote control at the signal reciever window
on the unit.
1
Press the TIMER ON ( 
 ) button.
• The time setting will change as you press the
button as follows.
Hold the button pressed down for fast setting.
• The orange TIMER lamp ( 
 ) on the unit will
light.
• The unit will generate a beep when it receives
the signal.
• The time setting will count down to show re-
maining time.
Select the mode, temperature and fan speed set-
ting as desired.
• When the temperature is set with the TIMER
ON, the temperature will show in the display for
5 seconds and then return to the time display.
• If you do not change the setting, the unit will
operate with the latest setting.
• The unit will turn on prior to the set time to allow
the room to reach the desired temperature by
the programmed time. (Awaking function)
NOTES FOR TIMER SETTING AND OPERATION
• The latest time setting will be memorized and will appear on the remote control display
the next time you set the TIMER OFF or TIMER ON.
• TIMER OFF and TIMER ON can not be set together.
The latest set TIMER will be active.
• When ONE-HOUR OFF TIMER is set, TIMER OFF and TIMER ON will not be available.
• When ONE-HOUR OFF TIMER is set during TIMER OFF or TIMER ON duration, the
TIMER ON or TIMER OFF will be cancelled.
MODE
DISPLAY MODE
FAN
1H
SWING CANCEL
TEMP.
TEMP.
FAN
TIMER
Example : When you wish the
room temperature
to be as desired
6.5 hours later.
0.5H
1.0H
1.5H
10H
11H
12H
E-14
AUXILIARY MODE
Use this mode when the remote control is not available.
TO TURN ON
Lift the front panel of the indoor unit and press the
AUX. button on the operation panel.
• The red OPERATION lamp ( 
 ) on the unit will
light and the unit will start operating in the AUTO
mode.
• The fan speed and temperature setting are set to
AUTO.
TO TURN OFF
Press the AUX. button on the operation panel again.
• The red OPERATION lamp ( 
 ) on the unit will
turn off.
NOTE:
If the AUX. button is pressed during normal opera-
tion, the unit will turn off.
OPTION KIT
Air Purifying Filter
During operation of the air conditioner, the air purifying
filter removes dust and tobacco smoke from the air and
discharges clean air.
The apatite antibacterial material used in the air purifying
filter suppresses activities of adsorbed viruses and other
germs.
The replacement period for the disposable type is
approximately 3~6 months.
Contact your dealer for the purchase of this option.
Type AZ-F900B
AUX.
Page of 127
Display

Click on the first or last page to see other AY-A07B (serv.man2) service manuals if exist.