ENGLISH
E-7
CAUTION
• Do not allow the signal receiver window to receive strong direct sunlight, since it can
adversely affect its operation. If the signal receiver window is exposed to direct sunlight,
close a curtain to block the light.
• Using a fluorescent lamp with a quick starter in the same room may interfere with
transmission of the signal.
• The unit can be affected by signals transmitted from the remote control of a television,
VCR or other equipment used in the same room.
• Do not leave the remote control in direct sunlight or near a heater. Also, protect the unit
and remote control from moisture and shock which can discolour or damage them.
Press the THERMO. button to set the
desired temperature.
AUTO/DRY MODE
The temperature can
be changed in 1°C in-
crements within the
range of 2°C higher to
2°C lower from the tem-
perature automatically
determined by the air
conditioner.
COOL(HEAT 
for AY-A07BE/AY-A09BE/AY-A12BE
)MODE
The temperature can
be set within the range
of 18 to 32°C.
1
E-8
BASIC OPERATION
2
Press the ON/OFF button to start op-
eration.
• The red OPERATION lamp ( 
 ) on the
unit will light.
3
4
1
4
5
2
3
(
 HEAT
 is only for AY-A07BE/AY-A09BE/AY-A12BE)
Press the MODE button to select the
operation mode.
AUTO
HEAT COOL
DRY
5
MODE
DISPLAY MODE
FAN
1H
SWING CANCEL
TEMP.
TEMP.
FAN
TIMER
Please the FAN button to set the de-
sired fan speed.
AUTO
SOFT
LOW
HIGH
• In the DRY mode, the fan speed is pre-
set to AUTO and cannot be changed.
To turn off the unit, press the ON/OFF
button again.
• The red OPERATION lamp ( 
 ) on the
unit will turn off.
ENGLISH
)
E-9
Automatic Operation
 Mode
Thermostat Setting
Below 21°C
HEAT
23°C
21°C-24°C
DRY
Room Temp. at start-up
24°C-26°C
COOL
24°C
26°C-28°C
COOL
25°C
Above 28°C
COOL
26°C
Automatic Operation
 Mode
Thermostat Setting
Below 24°C
DRY
Room Temp. at start-up
24°C-26°C
COOL
24°C
26°C-28°C
COOL
25°C
Above 28°C
COOL
26°C
TIPS ABOUT AUTO MODE
In the AUTO mode, the temperature setting and mode are automatically
selected according to the room temperature when the unit is turned on.
Modes and Temperature Settings for Models AH-A07BE/AH-A09BE/AH-A12BE
Modes and Temperature Settings for Models AY-A07BE/AY-A09BE/AY-A12BE
Room temp. at opera-
tion start-up
Room temp. at opera-
tion start-up
TIPS ABOUT FAN SPEED LAMP
During opration, the FAN SPEED Lamp will light up in 3 levels (2 levels
for DRY mode) on the indicator panel of the unit to indicate the fan
speed.
When fan speed is set to AUTO
When fan speed is set to manual
Soft speed
Low speed
High speed
The AUTO FAN SPEED Lamp
will light up.
To turn off the FAN SPEED Lamp, press
the DISPLAY button.
DISPLAY MODE
FAN
1H
SWING CANCEL
COOL and DRY mode
Horizontal air flow
HEAT mode 
(only for AY-A07BE/AY-A09BE/AY-A12BE)
Diagonal air flow
E-10
ADJUSTING THE AIR FLOW DIRECTION
VERTICAL AIR FLOW DIRECTION
The air flow direction is automatically preset in each mode as follows for optimum
comfort:
HOW TO ADJUST THE AIR FLOW DIRECTION
COOL and DRY mode
HEAT mode (only for
AY-A07BE/AY-A09BE/
AY-A12BE)
The adjustment range
is narrower the SWING
range in order to pre-
vent condensation from
dripping.
The range is wide so the
air flow  can be directed
toward the floor.
Hold the horizontal adjustment
louvre as shown in the diagram
and adjust the air flow direction.
Press the SWING button on the
remote control once.
• The vertical adjustment louvre
will change its angle continu-
ously.
Press the SWING button again
when the vertical adjustment lou-
vre is at the desired position.
• The louvre will stop moving within
the range shown in the diagram.
• The adjusted position will be
memorized and will be automati-
cally set to the same position
when operated the next time.
Adjustment range
HORIZONTAL AIR FLOW DIRECTION
CAUTION
Never attempt to adjust the vertical adjustment louvres manually.
• Manual adjustment of the vertical adjustment louvre can cause the unit to malfunction
when the remote control is used for the adjustment.
• When the vertical adjustment louvre is positioned at the lowest position in the COOL or
DRY mode for an extended period of time, condensation may result.
Page of 127