10.2 Convergence Adjustment
Procedure
Procedure
TOP
PREVIOUS
NEXT
1. Input a monoscope pattern of PAL.
2. Enter the Service Mode1.
3. Select the Coarse Convergence by pushing "RED" or "GREEN" buttons. Then push
"YELLOW" button, and push Position and [N] buttons to set the data to zero.
4. Stick the Convergence Adjustment Sheet (PAL 50Hz) onto the screen.
5. Push the “YELLOW” or “BLUE” on the remote control, and enter the Coarse Convergence
Adjustment mode.
6. Push the "0" of 10 key buttons, and then push the "N" of position buttons on the remote
control.
7. Enter to "TEST POS." mode.
8. Push the "5" button to display the monoscope pattern on the screen.
9. Adjust the position buttons so that the cursor in the center of the test pattern is aligned with the
center of the monoscope pattern.
10. Push the "TV/AV" button on the remote control, and enter the "DATA POS." mode.
11. Push the "5" button and close the background image (monoscope pattern).
12. Use the "+" and "-" of the position buttons so that the bump in the screen center line is at the
center of the cursor.
13. Push the "TV/AV" button twice, and enter the "OSD POS" mode.
14. Adjust the position buttons so that the cross-cursor is aligned near cross-bar.
15. Push the "SET UP" button, and "N" button to store data.
16. Push the "0" of 10 key buttons, and return to Coarse Convergence Adjustment mode.
TOP
PREVIOUS
NEXT
10.3 Coarse Convergence Adjustment
mode
mode
TOP
PREVIOUS
NEXT
10.3.1 Green Coarse Convergence Adjustment
10.3.2 Red Coarse Convergence Adjustment
10.3.3 Blue Coarse Convergence Adjustment
TOP
PREVIOUS
NEXT
Click on the first or last page to see other TX-43P800X / TX-43P800HM / TX-43P800HQ / TX-43P800HZ / TX-51P800X / TX-51P800HM / TX-51P800HQ service manuals if exist.