MECH-7 
 
1-7. How to Enter the Alignment Tape Data 
1.  Select the item “<4> Alignment Tape” on the LISTA main menu. 
2.  Select the item “<2> ENTRY” on the alignment menu. 
3.  After the screen displays the screen of <<Alignment Tape Data Entry>>, first input the Serial Number follow 
the printed number on the tape label. And input the number “0” or “1” for selected the PAL/NTSC. And after 
that    enter the tape type, input “0” for DVCPRO, input “1” for DV or input “2” for HDLP. 
4.  After selecting the tape type, the frame for inputting the DATA and CHECK SUM appears on the screen. Input 
the numerical value in numerical order on the data sheet, which is enclosed with alignment tape. If the wrong 
number is inputted, the error message on the screen, then confirm that data on the sheet. 
5.  After the data entry, the screen returns to “LISTA MAIN” menu. Confirm the serial number of the alignment 
tape. 
<< Alignment Tape Data Entry >> 
 
Serial No. Lrc-20 (NTSC)    10
µµµµ
 
[1] 
- 0.1   
[11] 
0.7  
[21] 
- 0.4   
[31] 
- 0.4 
[2] 
0.1  
[12] 
1.0  
[22] 
- 0.2   
[32] 
- 0.6 
[3] 
0.0  
[13] 
0.7  
[23] 
- 0.7   
[33] 
- 0.3 
[4] 
0.2  
[14] 
0.5  
[24] 
- 0.6   
[34] 
- 0.2 
[5] 
0.6  
[15] 
0.2  
[25] 
- 0.7   
[35] 
- 0.1 
[6] 
0.5  
[16] 
- 0.5   
[26] 
- 0.3   
[36] 
- 0.3 
[7] 
0.7  
[17] 
- 0.3   
[27] 
- 0.4   
[37] 
- 0.1 
[8] 
0.9  
[18] 
- 0.3   
[28] 
- 0.4   
 
 
[9] 
1.0  
[19] 
- 0.1   
[29] 
 - 0.6   
[CS] 
- 0.6 
[10] 
0.8  
[20] 
- 0.6   
[30] 
- 0.3   
 
 
 
 
NOTE:
 This is sample only, you must enter information from your alignment tape. Each tape is different. 
 
 
 
MECH-8 
 
1-8. LISTA Sensitivity Detection 
TP 
In case of use VFK1409A 
F2
 : ATF-ERR (VFK1409A),    TP2 : TRG/HSW (VFK1409A),    GND : GND (VFK1409A) 
In case of use VFK1409S 
F2
 : ATF-ERR (VFK1409S),    TP2 : TRG/HSW (VFK1810),    GND : GND (VFK1409S) 
VTR MODE 
PLAY 
ADJ. MODE 
Refer to below explanation 
TAPE 
VFM3000EDS (DV LISTA) 
SPEC. 
40 mV / 
µ
m to 120 mV / 
µ
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1.  Set the camera recorder to VCR mode. 
2.  Insert the DV Alignment Tape (VFM3000EDS) to the camera recorder. 
3.  Press the MENU button to open the “VCR FUNCTION MENU”
4. Open 
the 
“8. ADJUST MENU”
 in “VCR FUNCTION MENU”
5.  Select the item “ATF GAIN” and press the MULTI-DIAL. 
6. Message 
“NOW SERVO ADJUST PUSH MENU TO RETURN”
 appears on screen and press the PLAY button 
to playback the tape. 
7.  Press MENU button to return to “ADJUST MENU” screen. 
8. Select 
item 
“<1> Sensitivity Measurement”
 on the LISTA main menu, and press “ENTER”
9.  Then the tape is played back (tape speed : 101.2%) automatically, and message “1.2% Speed…” appears on 
the screen. 
10.  Press the ENTER key, and then start measurement of the sensitivity value. 
11. Confirm that the sensitivity value is with in specification, after the message “<<Sensitivity Measurement 
Finish>>”
 
 
 
 
 
 
 
 
 
Figure 9 
 
 
<<Sensitivity Measurement Finish>> 
 
Sensitivity 72.95 
(mV/um) 
    Sens.1 
65.43 (mV/um) 
    Sens.1 
85.48 (mV/um) 
 
Confirm that the value of Sens.Value1 
and Sens.Value2 in specification 
Select at Sensitivity Detection. 
MECH-9 
 
1-9. LISTA Linearity Adjustment 
TP 
In case of use VFK1409A 
F2
 : ATF-ERR (VFK1409A),    TP2 : TRG/HSW (VFK1409A),    GND : GND (VFK1409A) 
In case of use VFK1409S 
F2
 : ATF-ERR (VFK1409S),    TP2 : TRG/HSW (VFK1810),    GND : GND (VFK1409S) 
ADJ. 
S1 and T1 Post Height 
VTR MODE 
PLAY 
ADJ. MODE 
Refer to below explanation 
TAPE 
VFM3000EDS (DV LISTA) 
TOOL 
VFK1899 : Post Driver 
SPEC. 
Linearity : less than 3
µ
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1.  Set the camera recorder to VCR mode. 
2.  Insert the DV Alignment Tape (VFM3000EDS) to the camera recorder. 
3.  Press the MENU button to open the “VCR FUNCTION MENU”
4. Open 
the 
“8. ADJUST MENU”
 in “VCR FUNCTION MENU”
5.  Select the item “LINEARITY” and press the MULTI-DIAL. 
6. Message 
“NOW SERVO ADJUST PUSH MENU TO RETURN”
 is appears on screen and press the PLAY 
button to playback the tape. 
7.  Press MENU button to return to “ADJUST MENU” screen. 
8. Select 
item 
“<2> Linearity Measurement”
 on the LISTA main menu, and press “ENTER”, then the Linearity 
Waveform appears. 
9.  When the waveform as shown in figure below is displayed on the screen, press the “BS (Back Space)” key 
for display the waveform positioned at the center of the scale on screen. Adjust S1 and T1 post height by 
using the post driver so that the linearity waveform is becomes flat as possible, and it should be within 
specification. 
(Adjust linearity waveform in the red dot line on the screen.) 
 
Select at Linearity Measurement. 
MECH-10 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 10 
 
 
 
 
 
 
 
 
 
 
 
 
10. Press “SPACE” key to perform the Peak Hold in 30 seconds when linearity is displayed. 
11. After finishing the Peak Hold, press “SHIFT” and “ } ” key simultaneously on the Key Board, then the 
numerical values of “Linearity” and “Waving” is displayed on left lower portion of screen. And confirm the 
numerical value of “Linearity” is in the specification. If the “Linearity” is out of specification, adjust height of 
S1 and T1 post. 
12.  After this measurement is finished, press the ESC key to return to the main menu. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
POINT : 
The left side of the waveform (entrance side) is adjusted by the height of S1 post and the right side of the 
waveform (exit side) is adjusted by the height of T2 post. 
When the post driver is removed from upper part of post, linearity waveform is changed. 
After finishing this adjustment, eject the tape and insert the tape again to confirm that the shape of the linearity 
waveform has not changed. 
Adjust Linearity 
into this area. 
Confirm this value 