DOWNLOAD Panasonic PT-RZ770 / PT-RW730 / PT-RZ660 / PT-RW620 (serv.man2) Service Manual ↓ Size: 35.59 MB | Pages: 125 in PDF or view online for FREE

Model
PT-RZ770 PT-RW730 PT-RZ660 PT-RW620 (serv.man2)
Pages
125
Size
35.59 MB
Type
PDF
Document
Service Manual
Brand
Device
Projector / 1-CHIP DLP BASED PROJECTOR
File
pt-rz770-pt-rw730-pt-rz660-pt-rw620-sm2.pdf
Date

Panasonic PT-RZ770 / PT-RW730 / PT-RZ660 / PT-RW620 (serv.man2) Service Manual ▷ View online

INF-25
SECTION 1 SERVICE INFORMATION
< RZ770/RW730/RZ660/RW620 >
6. Troubleshooting
6. 1. Power/Light source/Temperature indicators
6. 1. 1. Power indicator
  •   Indicate the status of the power. Check the status of the power indicator <ON (G)/STANDBY (R)> before operating the 
projector.
Light source indicator <LIGHT1>
Light source indicator <LIGHT2>
Temperature indicator <TEMP>
Power indicator <ON (G)/STANDBY (R)>
Red
Lit
The power is switched off. (standby mode)
Projection will start when the power on <b> button is pressed.
 
f
The setting of the projector is as follows.
 
g
The [PROJECTOR SETUP] menu → [QUICK STARTUP] is set to [OFF].
 
f
The projector may not operate when the light source indicators <LIGHT1>/<LIGHT2> 
or the temperature indicator <TEMP> are blinking.
Blinking
The power is switched off. (standby mode)
Projection will start when the power on <b> button is pressed.
 
f
The setting of the projector is as follows.
 
g
The [PROJECTOR SETUP] menu → [QUICK STARTUP] is set to [ON].
 
f
The indicator will change to a red light when the specified time has elapsed after the 
projector enters the standby mode if the projector is set as following.
The specified time is the time set in the [PROJECTOR SETUP] menu → [QUICK 
STARTUP] → [VALID PERIOD].
 
g
The [PROJECTOR SETUP] menu → [QUICK STARTUP] is set to [ON].
 
f
The projector may not operate when the light source indicators <LIGHT1>/<LIGHT2> 
or the temperature indicator <TEMP> are blinking.
Green
Lit
Projecting.
Orange
Lit
The projector is preparing to switch off the projector.
The power is switched off after a while. (Changes to the standby mode.)
Note
f
  While the power indicator <ON (G)/STANDBY (R)> lights in orange, the fan is running to cool the projector.
f
  For approximately five seconds after the projector is turned off, the indicator does not light up even if the power is turned on. Turn on the 
power again after the power indicator <ON (G)/STANDBY (R)> lights/blinks in red.
f
  The projector consumes power even in standby mode (power indicator <ON (G)/STANDBY (R)> lights/blinks in red). Refer to “Power 
consumption” for the power consumption.
f
  When the projector receives the signal from the remote control, the power indicator <ON (G)/STANDBY (R)> will blink in the following color 
according to the status of the projector.
 
g
When the projector is in projection mode: Green
 
g
When the projector is in standby mode: Orange
However, if the [PROJECTOR SETUP] menu → [STANDBY MODE] is set to [ECO], the indicator will stay lit in red and will not blink if the 
projector is in standby mode.
 
f
The power indicator <ON (G)/STANDBY (R)> will blink slowly in green while the shutter function is in use (shutter: closed), or while the 
function of the [PROJECTOR SETUP] menu → [NO SIGNAL LIGHTS-OUT] is operating and the light source is turned off.
Indicator status
Projector status
Off
The main power is switched off.
INF-26
SECTION 1 SERVICE INFORMATION
< RZ770/RW730/RZ660/RW620 >
6. 1. 2. Light source indicators
  • If a problem occurs inside the projector, the light source indicators <LIGHT1>/<LIGHT2> will inform you by lighting or blink-
ing.
6. 1. 3. Temperature indicators
  • If a problem occurs inside the projector, the temperature indicator <TEMP> will inform you by lighting or blinking.
Indicator status
Status
Solution
Lighting in red
Some of the elements of the light 
source are defective and the light 
output has decreased.
f
  Turn the <MAIN POWER> switch to <OFF>, and turn on the 
power again.
Blinking in red
(1 time)
The light source is turned off since the 
projection lens cannot be detected.
f
  Turn off the power and mount the projection lens again.
f
  Turn the <MAIN POWER> switch to <OFF>, and turn on the 
power again.
Blinking in red
(2 times)
The light source does not light up, 
or the light source turns off while the 
projector is in use.
f
  Turn the <MAIN POWER> switch to <OFF>, and turn on the 
power again.
Blinking in red
(3 times)
Note
f
  If the light source indicators <LIGHT1>/<LIGHT2> are still lit or blinking after taking the measures, set the  <MAIN POWER> switch to 
<OFF>, and repairs.
f
  The light source indicator corresponding to the light source being lit will light up in green if the projector is in projection mode and there is no 
indication of problem by lighting or blinking in red.
f
  The function to detect the projector lens may or may not exist depending on the country or region where you purchased the product.
Indicator status
Lighting in red
Blinking in red
(2 times)
Blinking in red
(3 times)
Status
Warm-up status
Internal temperature is high 
(warning).
Internal temperature is high 
(standby status).
The cooling fan has 
stopped.
Cause
 
f
Did you turn on the power 
when the temperature 
was low (around 0 °C 
(32 °F))?
 
f
Is the air intake/exhaust port blocked?
 
f
Is the room temperature high?
Solution
 
f
Wait at least five minutes 
in the current status.
 
f
Use the projector 
in an appropriate 
operating environment 
temperature
*1
.
 
f
Remove any objects that are blocking the air intake/
exhaust port.
 
f
Use the projector in an appropriate operating 
environment temperature
*1
.
 
f
Do not use the projector at an altitude of 4 200 m 
(13 780') or higher above sea level.
f
 Repair 
*1  For details of operating environment temperature of the projector, refer to Operating Instructions “Operating environment temperature”.
INF-27
SECTION 1 SERVICE INFORMATION
< RZ770/RW730/RZ660/RW620 >
6. 2. Shutdown system
•   This projector provides the shutdown function to set into the standby mode immediately for product safety when the projector    
has the fan operation error or lightning error. 
Indicator status
Self-test
display
Shutdown detection
Probable cause
OSD warning, others
Not lighting or flashing
Power circuit (P-P.C.Board)
Fuse (F9001) : Rated 12A
Blown out of fuse
(with another reason)
Power circuit (P-P.C.Board)
Thermistor (CF9001, CF9002) : 115
±5℃
Air intake port blocked
Power circuit failure
STANDBY/ON blinks
3 times in red
F90/F91/F92 FPGA config error or communication 
error
Failure on signal processing part
F90:No response
F91:FPGA1 config error
F92:FPGA2 config error
Main firmware boot error
Main microprocessor rewrite error
A98
Formatter status error
DG-P.C.Board failure, 
Connector contact failure
FH0/FH1
FH2/FH3
Phosphor wheel rotation speed
 a
 Under 100Hz/8sec
 
*  FH1/FH3:Detected by FPGA
       (FH0/FH2:Detected by FM)
Connector contact failure
Phosphor wheel or drive circuit failure
CW-P.C.Board failure 
FH0/FH1:PW1
FH2/FH3:PW2
F85/F86
Color wheel rotation speed
 a
 Under 100Hz/8sec
 
*  F86:Detected by FPGA
       (F85:Detected by FM)
Connector contact failure
Color wheel or drive circuit failure
CW-P.C.Board failure 
STANDBY/ON lights
in red
TEMP lights
H11
Intake air temperature sensor
     a Lower than -20ºC
Intake air temperature sensor connector 
contact failure or disconnect
H12
Optical module temperature sensor
     a Lower than -20ºC
DMD temperature sensor error
(FM-P.C.Bosrd)
H13
Exhaust air temperature sensor
     a Lower than -20ºC
Exhaust air temperature sensor connector 
contact failure or disconnect
H14/H15
LD1 temperature sensor (H14)
LD2 temperature sensor (H15)
     a Lower than -20ºC
LD1/LD2 temperature sensor connector
contact failure or disconnect
TEMP blinks 3 times 
(In Warning: TEMP lights)
FE1 - FE9
FF0 - FF1
Each fan sense signal
     a  Fan rotation is lower than 70% of 
target for more than 5 seconds
Connector disconnection
Fan control circuit failure
Fan rotation error, end of life
If one of the fans stops, 
the projector reduces the 
LD output power.
If more than two fans have 
an error, the projector shut 
down.
FJ0 (PUMP1)
FJ1 (PUMP2)
Each pump sense signal
     a  Fan rotation is lower than 70% of 
target for more than 5 seconds
Connector disconnection
Pump control circuit failure
Pump rotation error, end of life
INF-28
SECTION 1 SERVICE INFORMATION
< RZ770/RW730/RZ660/RW620 >
Indicator status
Self-test
display
Shutdown detection
Probable cause
OSD warning, others
TEMP blinks 2 times 
(In Warning: TEMP lights)
U21
(U11)
Intake air temperature sensor
     a More than 48ºC *1
Abnormal intake air temperature
  External air temperature is high
  Ventilation holes are blocked
(More than 46ºC)
"TEMPERATURE 
WARNING"
U22
(U12)
Optical module temperature sensor
     a More than 75ºC *1
Abnormal DMD temperature
  External air temperature is high
  Ventilation holes are blocked
(More than 73ºC)
"TEMPERATURE 
WARNING"
U23
(U13)
Exhaust module temperature sensor
     a More than 65ºC *1
Abnormal exhaust air temperature
  External air temperature is high
  Ventilation holes are blocked
(More than 63ºC)
"TEMPERATURE 
WARNING"
U24
(U14)
Optical module temperature sensor
     a  Lower than 8 ºC for more than 5 
min, after power on.
Operating environment temperature is 
too low.
U25/U26
(U16/U18)
LD1 temperature sensor (U25)
LD2 temperature sensor (U26)
     a More than 80ºC *1
Abnormal LD units temperature
  External air temperature is high
  Ventilation holes are blocked
(More than 78ºC) 
"TEMPERATURE 
WARNING"
LIGHT blinks 3 times
FL1 (LD1)
FL2 (LD2)
LD driver microprocessor status
     a  Status is other than during normal 
operation
       *  If all of the LD units has become 
unlit, shut down
LD unit deterioration
Lighting failure of the LD units
LD driver circuit is abnormal
LIGHT blinks 2 times
FA8 (LD1)
FC8 (LD2)
LD driver microprocessor status
     a LD unit open fault
      *  If all of the LD units has become 
unlit, shut down
When "ERROR OSD" is 
set to ON
"LD*  ERROR"
 
 
 
 
*1 :   The threshold values are just reference temperature at operation mode (Normal), floor installed and less
                                                    than 1400m altitude. They are depending on the operating mode and installed condition.
 [Note]
 • 
[SELF TEST] can be checked in the [PROJECTOR SETUP] menu → [STATUS] → [SELF TEST].
 
  Can not checked if projector shutdown.
Page of 125
Display

Click on the first or last page to see other PT-RZ770 / PT-RW730 / PT-RZ660 / PT-RW620 (serv.man2) service manuals if exist.